HomeMy WebLinkAboutInspection - 296 RALEIGH TAVERN LANE 7/7/2015 aw
PUBLIC NEU'rli lttt5e"l"MENT
colvrwrrarrlty hvelopntena R)ivislnrr
TOWN OF NORTH ANDOVER RECEIVED
SEPTIC;DISPOSAL SYSTEM—INSTALLATION N C ERTIFIC'ATION
The undersigned hereby certify that the Sewage Disposal System( )constructed;( )repaired;
BY _ — d..li.AU F1:71 fJAR1M I'J
(Print Name) i i
Located at:,--- IX 166"1
(Installation Address)
Was installed in conformance with the North Andover Board of Health approved plan,originally dated
A! "" ,�g L+_and last revised oil_ ° °� with a design flow of
°�'Y4 gallons per day. The materials used were in conformance with those specified oil the
approved plan;the system was installed in accordance with the provisions of 310.C;MR 15.000,Title 5 and local
regulations,and the final grading agrees substantially with the approved plan.All work is accurately represented on
the As-built which has been submitted to the Board of Health.
Bottom of Bed Inspection Date:
M
,�. Engineer° el��°seen .�tive(Siguatu�°e)
And–Print Name
Final Construction Inspection late: t" I
Engineer Representative(Signature)
i L"L-' 00 11_11�2
And–Print Name
J� u
;installer. � ��' J (Signature) Date.
And–pan
t Name
En iner, 01W0114 Date; ;; , ,
VUomwil
And–Print Name
1600 Osgoo d Street, North Andaver, Massachusetts 01845
ilone 978.688.`t540 �Fttx 978.688.8476 Web isrtlii�:f�wwa "°tr w���ri��o�..ii�r�pm��urwarr"ttr�r�
Town of North Andover — Se t�vstem - AS-BUILT CHECKLIST
1) v All changes to the design plan have been reflected and noted on the as-built plan
2) As-built plan has a suitable scale; (1 inch = 40 feet or fewer for plot plans)
3) Street Address,Assessor's Map and Lot Number
4) Lot Lines and Location of Dwellings served by the system
5) Locations,Elevations and Dimensions of As-built system components,including reserve (if applicable)
6) Ties to all tank openings,d-box,and leach area from dwelling or Permanent Structure
7) --L—Setback distances are shown on the as-built plan from system components to:
subsurface,interceptor&foundation drains
Catch basins
Property lines
✓ Dwellings or other structures
Private water supply or irrigation wells
' Watercourses or wetlands
8) Locations of Wells,Drains,Wetland Resource Areas within 150 feet of system
9) Location of water,gas,electric lines,cable,control panel (if applicable)
10) Location of Structures within 6 Inches of Finished Grade
11) Original Stamp &Signature
12) Location and holder of any easements which could impact the system
13) Impervious Areas;Driveways,etc
14) North Arrow
15) `'" Location&Elevation of Benchmark used
16) STATEMENT ON PLAN (NA 5.3)
a. "I certify the locations, elevations, ties, cover material;exposed component covers etc.,
shown on this as-huiltsuhstantiallyagvee witli the appr~ovedplan and have determined that the
hreak out cle nations,if applicable,have been rnet."
Signature of Designer Date
b. "If a STUCTURAL WALL IS PRESENT(NA 4.9)a Letter or statenierzt on the as-built indicating
the wall- was or was note constructed in accordance with the intended design andany
manufacturer's specifications."
Signature of Designer Date
As of:Monday,July 20,2015
•
North Andover Health Department
Community and Economic Development Division
UNSITE WASTEWATER SYSTEM CONSTRUCTION NOTES
LOCATION INFORMATION
ADDRESS: 296 Raleigh Tavern Lane MAP: 106C LOT: 112
INSTALLER: Todd Bateson
DESIGNER: Merrimack Engineering
PLAN DATE: 12/4/14
BOH APPROVAL DATE ON PLAN: 4/23/15
INSPECTIONS
TANK INSPECTION:
DATE OF BED BOTTOM INSPECTION:6/17/15
DATE OF FINAL CONSTRUCTION INSPECTION: 6/24/15
DATE OF FINAL GRADE INSPECTION: t" l
SITE CONDITIONS
N/A Contractor reports any changes to design plan
® Existing septic tank properly abandoned
® Internal plumbing all to one building sewer
® Topography not appreciably altered
Comments:
SEPTIC TANK
® Building sewer in continuous grade, on
compacted firm base
® Cleanouts per plan
X Bottom of tank hole has 6" stone base
X Weep hole plugged
X 1500 gallon tank has been installed
H-10 loading
X Monolithic tank construction
® Water tightness of tank has been achieved by
visual testing
X Inlet tee installed, centered under access port
F71 Outlet tee installed, centered under access port
(effluent filter)
® 24" inch cover to within 6" of finish grade
installed over one access port
X Neoprene boots around inlet & outlet
Comments: 7426
PUMP CHAMBER
X Bottom of tank hole has 6" stone base
® Weep hole plugged
X 1500 gallon Pump Chamber installed
X H-10 loading
X Monolithic tank construction
X Inlet tee installed, centered under access port
® Pump(s) installed on stable base
® Alarm float working
® Pump On/Off floats working
® Separate on/off floats
® Drain hole in pressure line
® 24" cover at final grade installed over pump
access port
® Water tightness of tank has been achieved by
Visual testing
® Neoprene boots around inlet & outlet
Comments:
CONTROL PANEL
® Alarm & Pump are on separate circuits
® Alarm sounds when float is tripped
® Location of control panel: basement
® Alarm signal located inside: basement
Comments:
DISTRIBUTION-BOX
® Installed on stable stone base
® H-20 D-Box
® Inlet tee (if pumped or >0.08'/foot)
® Hydraulic cement around inlet & outlets
® Observed even distribution
N/A Speed levelers provided (not required)
® Schedule 40 PVC Pipe
Comments:
SOIL ABSORPTION SYSTEM (General)
X Bottom of SAS excavated down to C soil layer,
as provided on plan
X Size of SAS excavated as per plan
X Title 5 sand installed, if specified on plan
® 40 Mil HDPE barrier installed
® Laterals installed and ends connected to
header (and vented if impervious material
above)
® Elevations of laterals and chambers installed as on
approved plan
❑ Retaining wall (boulder/ concrete /timber/ block)
❑ Final cover as per plan
Comments: 74'x26 w field
SOIL ABSORPTION SYSTEM (Gravel-less Chambers)
® Brand and Model of Chamber: Standard Quick
4 Low Profile Infiltrator Chambers
® Number of chambers per row: 16
® Number of rows (trenches): 6
Comments: Total Chambers = 96
FINAL GRADE
Loamed
Seeded
Cover per plan
Comments:
DOCUMENTS NEEDED
Certification of Installation Form submitted
By engineer and signed and dated by
Engineer and installer
�As-Built Plan
BM = 154.50
HR = 4.76
HI = 159.26
SYSTEM ELEVATIONS
ROD AS-BLT INVERT DESIGN INVERT
ELEVATION ELEV ELEV
Benchmark
Building Sewer OUT 5.49 153.42 153.4
Septic Tank IN 5.98 152.93 153.00
Septic Tank OUT 6.20 152.71 152.75
Pump Chamber IN 6.24 15167 152.70
(2") Pump Chamber OUT 6.70 152.39 -----
(2") Distribution Box IN 4.57 154.52 154.50
Distribution Box OUT 4.58 154.33 154.33
Lateral 1 TOP 4.60
Lateral 1 INVERT 154.31 154.28
Lateral 2 TOP 4.61
Lateral 2 INVERT 154.30 154.28
Lateral 3 TOP 4.62
Lateral 3 INVERT 1 54.29 154.28
Lateral 4 TOP 4.62
Lateral 4 INVERT 154.29 154.28
Lateral 5 TOP 4.61
Lateral 5 INVERT 154.30 154.28
Lateral 6 TOP 4.60
Lateral 6 INVERT 154.31 154.28
Top of Chamber 4.60 154.66 154.67
Bottom of Bed/Chamber 5.25 154.01 154.00
CRITICAL SETBACK DISTANCES
Mark those distances checked in the field against the design plan and regulatory
setback
Tank SAS Sewer
® Property line 1.0 10 --
® Cellar wall 10 20 --
® Inground pool 10 20 --
® Slab foundation 10 10 --
® Deck, on footings, etc 5 10 --
® Waterline 10 10 10'
® Private drinking well 75 1002 50
® Irrigation well 75 100
® Surface Water 25 50
® Bordering Vegetated Wetland ,
Salt Marsh, Inland/Coastal Bank 75 100
® Wetlands bordering surface
water supply or trib. (in Watershed) 150 150
® Trib. to surface water supply 325 325
® Public well 400 400
® Interim Wellhead Prot. Area
® Reservoirs 400 400
® Drains (wat. supply/trib.) 50 100
® Drains (intercept g.w.) 25 50
® Drains (Other)Foundation 10(5) 20(10)
® Drywells 20 25
Suction line 222(2)
2 100 feet is a minimum acceptable distance and no variance is allowed for a lesser distance(NA 5.02).
3 As defined in 310 CMR 10.55, 1032, 10.54,and 10.30,respectively,pursuant to 15.211(3),also by NA
wetland bylaws