HomeMy WebLinkAboutInspection - 445 BOSTON STREET 1/28/2010 44 Commercial Street
Raynham, MA
02767
Tel: (508)880-0233
Fax: (508)880-7232
0dr !°41V`4fls. NL)OV ,IR
January 28, 2010 � t PRNKAE1`T
North Andover Board of Health
1600 Osgood Street
North Andover, MA 01845
Attention: Health Agent
Reference: EAST" Wastewater Treatment System._- Serial Number: 21762
C
Attached please find the Field Inspection & Service Report with eld test results for
services performed on 1/13/10 at the property of Thomas Connoll located at 445 Boston
Street, North Andover, MA.
Please call if you have any questions or require additional information.
Sincerely,
Wastewater Treatment Services, Inc.
Service Department
Enclosures
Copy to: Thomas Connolly
Massachusetts DEP
Massachusetts Department of Environmental Protection
Bureau of Resource Protection -Title 5
DEP Approved Inspection and O&M Form for Title 5 I/A
Ll
Treatment and Disposal Systems
13556
A. Installation
Thomas Connolly
Owner
445 Boston Street
Facility Street Address
North Andover 01845
City Zip
Mailing address of owner, if different:
445 Boston Street _
Street Address/PO Box:
North Andover MA 01845
City State Zip
978 975 7694
Telephone Number
B. Authorized Service Provider
Wastewater Treatment Services Inc.
O&M Firm
44 Commercial Street
Street Address
Raynham MA 02767
City State Zip
508-880-0233
Telephone Number
Kevin Usilton 12530
Certified Operator Name Certification Number
C. Facility/System Information
21762 Bio-Microbics Inc. MicroFAST .5
DEP ID Manufacturer ID Model Number
1/6/2003 1/6/2003
Installation Date Start of Operation
Approval Type: [] General [] Provisional [] Piloting [x] Remedial
Seasonal Residence—used less than 6 mo./year: []Yes [x] No
D. Operating Information
1/13/10
Inspection Date Previous Inspection Date
191, Pumping Recommended [x] Yes [] No
Sludge Depth(to be checked yearly)
1
Massachusetts Department of Environmental Protection
Bureau of Resource Protection -Title 5
1
I � DEP Approved Inspection and O&M Form for Title 5 VA
Treatment and Disposal Systems
13556
E. Field Testing
Field Inspection:
Color: 0 gray 0 brown [x] clear 0 turbid
0 Other (specify):
Odor: musty [x] earthy Q moldy 0 offensive [] turbid
Effluent Solids: [x ] no [] some
pH 7 SU DO 9.12 mg/L Turbidity 1.02 NTU
6 to 9 2 or greater 40 or less
Should a Remedial or General Use system fail the Field Testing, effluent samples shall be
collected per Standard Methods and analyzed for BOD and TSS.
F. Sampling Information
Samples Taken: [] Influent [] Effluent
Commercial systems or systems with a design flow of 2000 gpd and greater, and General Use
nitrogen reducing systems:
440
gpd
Parameters sampled: [] pH [] BOD [] CBOD [] TSS []TKN [] Nitrate [] Nitrite []
Phosphorus [] Spec. Cond. []Ammonia []Alkalinity [] Oil Grease [] VOC [] Fecal Coliform
G. Inspection and Maintenance
Description of any maintenance performed since previous inspection & during this inspection:
Cleaned Filter Checked Splash Recycle
Notes and Comments:
2
Massachusetts Department of Environmental Protection
Bureau of Resource Protection -Title 5
(; DEP Approved Inspection and O&M Form for Title 5 I/A
Treatment and Disposal Systems
13556
H. Certification
I certify: I have inspected the sewage treatment and disposal system at the address above, have
conducted the required Field Testing and/or sample collection in accordance with Standard
Methods, have completed this report and the attached technology operation and maintenance
checklist, and the information reported is true, accurate, and complete as of the time of the
inspection. I am a Massachusetts certified operator in accordance with 257 CMR 2.00.
r,
1/13/10
Operator Signature Date
System owner must submit this report, technology O&M checklist, and any required sampling
results to the local board of health and DEP as follows for each inspection performed:
Remedial Use—by January 31 st of each year for the previous calendar year
Piloting Use -within 45 days of inspection date
Provisional Use—by March 31 th of each year for the previous 12 months
General Use—by September 30th of each year for the previous 12 months
Send to:
Department of Environmental Protection
Attention: Title 5 Program
One Winter Street, 6th Floor
Boston, MA 02108
3
1
5 INCORPORATED
8450 Cole Parkway, Shawnee, KS 66227, Phone 913-422-0707, Fax 913-422-0808
e-mail:onsite biomicrobics.com, www.biomicrobics.com, 800-753-FAST(3278)
FIELD INSPECTION & SERVICE REPORT
For Bio-Microbics Single Home FAST System
-- --- ----- - 13556
INSTALLATION AUTHORIZED SERVICE PROVIDER
Installation Address: 445 Boston Street Name:Wastewater Treatment Services,Inc.
North Andover,MAO 1845
Owner Name:Thomas Connolly
Mail Address: 445 Boston Street Mail Address: 44 Commercial Street
North Andover,MA 01845 Raynham,MA 02767
Phone:978 975 7694 Fax: e-mail: Phone:(508)880-0233 Fax:(508)880-7232 e-mail:
INSTALLATION INFORMATION
Model No. Serial No. Date of Installation Date of last pump out
M icroFAST.5 21762 1/6,12003 1/l/2006
EQUIPMENT YES NO MAINTENANCE PERFORMED AND COMMENTS
Electrical Panel(s)
Visual Alarm Operating x
Audio Alarm Operating x
(if present)
Blower(s)
Air Inlet Filter Clean x
Blower Hood Vents Clear x
Excessive Noise x
Excessive Vibration x
Treatment unit(s)
Unusual Odor x
Pumpout Required x
Primary Settling Zone 191,
Aerobic Treatment Zone 15"
EFFLUENT(optional) LIMIT RESULT
Estimated Daily Flow 440 gpd
pH(Standard Units) 7
Color
Temperature 51
Odor Earthy
Comments:
TECHNICIAN SERVICE DATE
Kevin Usilton 1/13/10