HomeMy WebLinkAboutCorrespondence - 105 WINTERGREEN DRIVE 10/12/1999 .�. .......»............................
.......�..........,.�.......................,.,�....«...._ ...�..._.... . �,.�.. ....�
NEW ENGLAND J
ENGINEE"FRING SERVICES
..,„',.a ..,....,.,.,.,... ......... .......,....,..... ....,._......,...,......................... .......... .. ... .._ .......... .».,......... .
October 12, 1999
Sandra Starr, Administrator
North Andover Health Department
Town Hall Annex.
27 Charles Street
North Andover, MA 01845
Re; 105 Wintergreen Drive,North.Andover, Septic system design
Dear Sandra:
Enclosed you will find five copies of a septic system design for the above referenced
property. These plans are being submitted for approval. The following additional items
are also being submitted.
1. Soil evaluator sheets.
2. Application form.
3. Check to cover the fee.
4. Form 9A Local Upgrade Request Form
5. Request to have the local variances and upgrade approvals considered at the next
Board of Health meeting.
If you have any questions or need additional information please do not hesitate to contact
this office.
Sincerely,
Benjamin C. Osgood, Jr., EIT
President
P.S. Please note that our new address is 60 Beechwood Drive, North Andover.
0 43EEC HWOOD DRIVE-NORTH ANDOVER, MA 01845..(978)686-1.708 -(888) 9®'7645..FAX(978)685-9099
. ..........o _... . ... �..� ...�. _.. . _..... _ _. .
NIEW i ENGLAND WM
INC ...... ... .. ._.__.............._.... ...w.�_.. _. ...... . w. � .. ..
October 12, 1999
Sandra Starr, Administrator
North Andover Health Department
Town Hall Annex
27 Charles Street
North Andover, MA 01 845
Re: 105 Wintergreen Drive,North Andover septic system design
Dear Sandra:
Please accept this letter as a request to have the following local upgrade approvals and
local variances considered for approval at the next Board of Health meeting.
Local Upgrade Approvals:
1. Reduction in the offset distance between the bottom of the leach field and the water
table from 5 feet required by Title 5 section 15.212(b) to 4 feet.
2. Reduction in the offset distance between the leach field and the foundation wall from
the 20 feet required by Title 5 section 15.211(1)to 10 feet.
Local Variance Required:
1 Reduction in the offset distance between the leach field and the wetlands from 100
feet required to 50 feet.
2 Allow the use of a 20 mill poly barrier in lieu of a concrete wall for slope reduction.
If you have any questions or need additional information please do not hesitate to contact
this office. I will attend your next Board of Health meeting to discuss this matter.
Sincerely,
Benjatiin C. Osgood, Jr., EIT
President
60 B EEC HWOOD DRIVE- CSC') '"m AN DOVER,MA 01845-(978) €6.,176 5••(8 )359-7645-F-AX(97 ) 85-1099
Oct-15-99 08: 19A Paul D. Turbide9 PE/PLS 508-465-0313 P.03
October 15, 1999
Sandra Starr
North Andover Board of Health Administrator
Office of Community Development and Services
30 School St.
North Andover, MA 01 845
RE; Title V review for 105 Wintergreen Drive
Dear Sandra,
I find that the design plans dated Sept 27, 1999 adequately address the regulations.
Note that this upgrade design requires local variances for reduction in the offset
distance between the bottom of the leach bed and the groundwater from 5' to 4', and
reduction of offset from leach bed to foundation wall from 20' to 10'.
If you have any questions or comments please feel free to contact me.
Sincerely
Carlton A. Brown, PUPLS
WintergT�enl OS.doc
PORT
ENGINEERING
Civil Engineers K
Land Surveyors
One Harris Street
Newburyport,NIA
01950
(978)465-8594