Loading...
HomeMy WebLinkAboutCorrespondence - 154 MAIN STREET 10/14/2008 tAORTiN 61 0 0 North Andover Planning Board !(Meeting Date: OA'rr�; Agenda cw5l,, 1. PLANNING DEPARTMENT Community Development Division AGENDA ITEM #8 TO: Planning Board FROM: Judy Tymon,Town Planner RE: CB Richard Ellis, Global Corporate Services (applicant),Bank of America, 154 Main Street,Assessors Map 41,Parcel 33. Site Plan Review Special Permit to re- construct and expand the existing parking and driveway area,by removing the existing rear drive-thru aisle and increasing the parking area by 6 spaces,plus related landscaping and stormwater management improvements, in the General Business District. DATE: I"Review—October 14,2008 Proposal: The applicant, CB;Richard Ellis,Global Corporate Services (applicant),is seeking a Site Plan Special Permit to re-construct and expand the existing parking and driveway area,by removing the existing rear drive-thru aisle and increasing the parking area by 6 spaces,plus related landscaping and stormwater management improvements. The parking lot is serves the 154 Main Street location of the Bank of America, which has been in that location for about fifteen years. The applicant proposes to expand the parking lot by eliminating the rear drive-thru aisle, so as to allow for six more parking spaces. This expansion will result in the addition of 2000 SF of parking area,however, 1000 SF will be removed,resulting in a net increase of 1000 SF. Current zoning requires six parking spaces and this expansion will result in a total of eighteen parking spaces. The site does not currently have stormwater management system and the applicant is proposing new stormwater structures,including a deep sump catch basin,a filtration chamber and a series of recharge units. These applicant's proposal in intended to provide not only an increased number of parking spaces,but also an improved storm water management system,improved traffic patterns on the site and improved handicap accessibility. Below please find my review of the following plans submitted to this Department: Plan titled: Site Plan&Existing Conditions Plan 154 Main Street North Andover,Massachusetts 01845 Prepared for: CB Richard Ellis Global Corporate Services 1075 Main Street Waltham,MA 02451 Prepared by: Cavanaro Consulting 687 Main Street Norwell,MA 02061 Scale: 1"=20' Date: September 11,2008 Sheets: 1 -2 Background: ➢ This is the 1,d Public Hearing for the Application. The application is currently undergoing a review by the Town's Outside Consultant,VHB. Y The applicant has applied for a Notice of Intent with the Conservation Commission, who held a public hearing on October X 2008. The hearing was continued until 10/22/08. See section"xi: LOCATION OF WETLANDS/NOTICE OF INTENT"for more details. The following items were discussed with the Commission: ➢ Submission of a planting plan showing revegetation of the slope below the proposed retaining wall and of a disturbed area at the toe of slope. ➢ A plan showing a higher retaining wall(extend wall to proposed guardrail height)for safety as well as to prevent snow stockpiling on the bank above the pond. viiSi=ULion of a poured concrete retaining wall. Wall could lie decoratively faced. Abutters are concerned with appearance of the wall. ➢ Detail on how proposed wall will connect with existing retaining wall on southern property boundary. ➢ Addition of a catch basin. ➢ Abutters on the southern property boundary requested a stockade fence between the properties (not to restrict wildlife movement around the pond). SITE PLAN REVIEW: i. NORTH ARROW/LOCATION MAP: A North Arrow is located on the upper right side of the plan. Addressed. ii. SURVEY OF LOT/PARCEL: The lot area is displayed on the plan. Map 41, Lot 33 consist of 19,842 SF.Addressed iii. NAME/DECRIPTION OF PROJECT: The name and description of the project have been provided in the title block and a review is located in the application narrative. Addressed iv. EASEMENTS/LEGAL CONDITIONS: A"sewer"easement is shown on the plan. Addressed V. TOPOGRAPHY: Sufficient grading information has been shown on the plan,in particular on the eastern side of the property,behind the proposed retaining wall,where there is a significant slope to the pond.Addressed vi. ZONING INFORMATION: The zoning district information and parking requirements are shown on the plans. The project is located within the General Business District.Addressed vii. STORMWATER DRAINAGE: The applicant is proposing significant improvements to the drainage system, including a deep sump pump, filtration chambers and recharge units. The new systems should provide for approximately 78%TSS removal. A stormwater drainage study was submitted and has been reviewed by the Town Consultant. Stormwater will be managed in accordance with DEP's Stormwater Management Policy and related technical guidance and reviewed separately by the Conservation Commission as a part of the wetland review process. viii. BUILDING LOCATION: The location of the existing office building is shown on the plans. Addressed ix. BUILDING ELEVATION: The building height and footprint will not change.Addressed X. LOCATION OF PARKING/WALKWAYS: The plan shows a total of 18 proposed parking spaces. The zoning requirement is for 6 spaces and the site currently has 12 spaces. The plan also shows the new driveway patterns,new traffic aisles and improved handicap accessibility. xi. LOCATION OF WETLANDS/NOTICE OF INTENT: Wetlands have been correctly delineated on the plans. The applicant filed an application.vlth the Cons.xvat.on Commission and is currently going through the process. The following items were discussed with the Commission ➢ Submission of a planting plan showing revegetation of the slope below the proposed retaining wall and of a disturbed area at the toe of slope. ➢ A plan showing a higher retaining wall (extend wall to proposed guardrail height)for safety as well as to prevent snow stockpiling on the bank above the pond. ➢ Consideration of a poured concrete retaining wall. Wall could be decoratively faced. Abutters are concerned with appearance of the wall. ➢ Detail on how proposed wall will connect with existing retaining wall on southern property boundary. ➢ Addition of a catch basin. ➢ Abutters on the southern property boundary requested a stockade fence between the properties(not to restrict wildlife movement around the pond). xii. LOCATION OF WALLS/SIGNS: The applicant is proposing the relocation of an existing sign to be compatible with the proposed changes to the parking area.Addressed xiii. LOCATION OF ROADWAYS/DRIVES: The proposed parking lot aisles meet the 25' width required between parking spaces, as stated in Section 8.1(7)of the Zoning Bylaw. The aisle in the rear of the building has a width of 15' and the aisle on the northwest side has a width of 10.5'. The applicant should confirm with the Fire Department that the proposal will provide adequate access for safety vehicles. xiv. OUTDOOR STORAGE/DISPLAY AREAS: There are no proposed changes to outdoor storage or display areas. A landscaping plan should include screening for the existing AC unit in the front of the building. xv. LANDSCAPING PLAN: The applicant has not provided a landscape and lighting plan. The applicant will need to demonstrate how the landscape meets Section 8.4 which states: For all commercial and industrial districts the following minimum screening and landscaping requirements shall apply for all off-street lots with more than 6 parking spaces, or in any instance when a commercial or industrial off-street parking area of any size abuts a residential district. 1. A strip of land at least six(6)feet wide (may be part of required yard setbacks) with trees or shrubs densely planted, to create at least an impervious screen, at least four(4)feet high at the time ofplanting and which are of a type that may be commonly expected to form a year round impervious screen at least five (5)feet high within three years. 2. If a natural screen as described in item I above cannot be attained, a wall or fence of uniform appearance at least five (5)feet high above finished grade will be allowed. Such a wall and/or fence may be perforated,provided that not more than 25%of the face is open. 3. All required screening, as described in items 1 and 2 above, shall be maintained in good condition at all times. Such screening may be interrupted by entrances or exits, and shall have no signs attached thereto other than those permitted in the district. ThYough the Site Dl— Review: Special Pelil 4 process,the Platming Board may mod.l,>certain parking/loading standards,as stated in Section 81). Modification of Screening and Landscaping Requirements for Off-Street Parking. Where it can be demonstrated to the satisfaction of the Planning Board that a plan for screening and landscaping would be enhanced without detriment to the surrounding neighborhood through the waiver or modification of one or more of the screening, landscaping and other criteria setforth under Section 8.4. xvi. REFUSE AREAS/DISPOSAL: There are no proposed changes to refuse/disposal areas. Addressed avii. LIGHTING FACILITIES: There are no proposed changes to exterior lighting.Does the applicant intend to propose additional lighting for the new parking spaces and driving aisle in the rear of the site? xviii. DRAINAGE BASIN STUDY: A drainage report has been submitted and is being reviewed by the Outside Consultant. xix. TRAFFIC IMPACT STUDY: The applicant has stated that since the existing use of the site will not change, there will be no change in traffic. The applicant should submit a waiver for this requirement. xx. COMMONWEALTH REVIEW: The applicant has filed a Notice of Intent with the town's Conservation Commission. xa i. UTILITIES: There will be no changes to the utilities,with the exception of stormwater management.Addressed Xxii. FISCAL IMPACT: No fiscal impact study has been completed. The applicant should request a waiver. xxiii. COMMUNITY IMPACT: No community impact study has been completed. The applicant should request a waiver. GENERAL COMMENTS 1. Landscaping: The town's Zoning Bylaw, Section 8 Screening and Landscaping Requirements for Off-Street Parking does require that some landscaping for parking lots be provided as screening from abutting properties. If natural landscaping is not possible, a wall or fence may be substituted. Since the applicant is proposing more parking than is required and is proposing a retaining wall of a significant height(up to 8'),there may be an opportunity to re-design the lot to include landscaping to provide screening for not only abutting properties but also to provide a more aesthetic view from the street. Also, landscaping using LID techniques may help to mitigate stormwater management. 2. Parking and Roadway Design: The applicant should have the plan reviewed by the Fire and Police Departments to be sure that the new traffic patterns for the driveway aisles and the width of the driveway aisles provide for convenient and safe manipulation of safety vehicles. 3. Lighting for new parking area. The plans do not indicate any increased lighting for the new parking lot design. The applicant may want to consider additional lighting in the rear of the building for safety purposes. DRAINAGE COMMENTS: The VHB report will provide comments.. RECOMMENDATIONS: The Planning Department recommends continuing the application to allow the applicant to respond to the Town Staff and VHB's comments and revise the plans accordingly. Cc: applicant Engineer DPW Fire Department Building Department