HomeMy WebLinkAboutCorrespondence - 385 RALEIGH TAVERN LANE 1/1/2015 G/l/..CC.�1iL�,��ei�/! G//1,�•lTi7if�2E�C .,Ct/1��il�C°�4, �!?�f°�
44 Commercial Street
Raynham,MA
02767
Tel: (508)880-0233
Fax: (508)880-7232
RECEIVED
May 27, 2015
Tt` ate(,)N PJ,MOV R
�i U'H Dry AR EN cm
North Andover Board of Health
1600 Osgood Street
North Andover, MA 01845
Attention: Health Agent
Reference: Hoot° Wastewater Treatment System - Serial Number: 20951
Attached please find the Field Inspection & Service Report with field test results for
services performed on 4/3/15 at the property of Robert Lynch located at 385 Raleigh
Tavern Lane,North Andover, MA.
Please call if you have any questions or require additional information.
Sincerely,
Wastewater Treatment Services, Inc.
Service Department
Enclosures
Copy to: Robert Lynch
Massachusetts DEP
Wiggin Precast
Massachusetts Department of Environmental Protection
LlBureau of Resource Protection -Title 5
DEP Approved Inspection and O&M Form for Title 5 I/A
Treatment and Disposal Systems
23967
A. Installation
Robert Lynch
Owner
385 Raleigh Tavern Lane -
Facility Street Address
North Andover 01845
City Zip
Mailing address of owner, if different:
385 Raleigh Tavern Lane
Street Address/PO Box:
North Andover MA 01845
City State Zip
Telephone Number
B. Authorized Service Provider
Wastewater Treatment Services Inc.
O&M Firm
44 Commercial Street
Street Address
Raynham MA 02767
City State Zip
508-880-0233
Telephone Number
Michael Moreau 10291
Certified Operator Name Certification Number
C. Facility/System Information
20951 Bio-Microbics Inc. Micro FAST .5
DEP ID Manufacturer ID Model Number
1/11/2002 1/11/2002
Installation Date Start of Operation
Approval Type: [] General [] Provisional [] Piloting [x] Remedial [] General Denite
Seasonal Residence—used less than 6 mo./year: [ ]Yes [x] No
D. Operating Information
4/3/15
Inspection Date Previous Inspection Date
16" Pumping Recommended []Yes [x] No
Sludge Depth(to be checked yearly)
1
Massachusetts Department of Environmental Protection
Bureau of Resource Protection -Title 5
DEP Approved Inspection and O&M Form for Title 5 I/
Treatment and Disposal Systems
23967
E. Field Testing
Field Inspection:
Color: [] gray [x] brown [] clear [] turbid
[] Other (specify):
Odor: [] musty [x] earthy [] moldy [] offensive []turbid
Effluent Solids: [] no [x] some
pH 6 SU DO 5.40 mg/L Turbidity 4.30 NTU
6 to 9 2 or greater 40 or less
Should a Remedial or General Use system fail the Field Testing, effluent samples shall be
collected per Standard Methods and analyzed for BOD and TSS.
F. Sampling Information
Samples Taken: [] Influent [] Effluent
Commercial systems or systems with a design flow of 2000 gpd and greater, and General Use
nitrogen reducing systems:
440
gpd
Parameters sampled:
Influent. [ ] pH [] BOD [] CBOD []TSS []TKN [ ] Nitrate [] Nitrite [] Phosphorus [ ] Spec.
Cond. []Ammonia []Alkalinity [] Oil Grease []VOC [] Fecal Coliform
Effluent: [] pH [] BOD [] CBOD [ ]TSS []TKN [] Nitrate [] Nitrite [] Phosphorus [] Spec.
Cond. [ ]Ammonia []Alkalinity [] Oil Grease []VOC [] Fecal Coliform
G. Inspection and Maintenance
Description of any maintenance performed since previous inspection &during this inspection:
Cleaned Filter Checked Splash Recycle Pump(s) Inspected Float(s) Inspected
Notes and Comments:
Pumps and floats have been inspected and are operation
2
Massachusetts Department of Environmental Protection
Bureau of Resource Protection -Title 5
®EP Approved Inspection and O&M Form for Title 5 I/
Treatment and Disposal Systems
23967
Ha Certification
certify: I have inspected the sewage treatment and disposal system at the address above, have
conducted the required Field Testing and/or sample collection in accordance with Standard
Methods, have completed this report and the attached technology operation and maintenance
checklist, and the information reported is true, accurate, and complete as of the time of the
inspection. I am a Massachusetts certified operator in accordance with 257 CMR 2.00.
AX11 1/10
JJ 4/3/15
Operator Signature Date
System owner must submit this report, technology O&M checklist, and any required sampling
results to the local board of health and DEP as follows for each inspection performed:
Remedial Use—by January 31 st of each year for the previous calendar year
Piloting Use -within 45 days of inspection date
Provisional Use—by March 31th of each year for the previous 12 months
General Use— by September 30th of each year for the previous 12 months
Send to:
Department of Environmental Protection
Attention: Title 5 Program
One Winter Street, 6th Floor
Boston, MA 02108
3
e
,_ -i i �i�C ❑ R P ❑ R A T E
8450 Cole Parkway, Shawnee, KS 66227, Phone 913-422-0707, Fax 913-422-0808
e-mail:onsite biomicrobics.com, www.biomicrobics.com, 800-753-FAST(3278)
FIELD INSPECTION cot SERVICE REPORT
For Bio-Microbics Single Home FAST°System
23967
INSTALLATION AUTHORIZED SERVICE PROVIDER
Installation Address: 385 Raleigh Tavern Lane Name:Wastewater Treatment Services,Inc.
North Andover,MA 01845
Owner Name:Robert Lynch
Mail Address: 385 Raleigh Tavern Lane Mail Address: 44 Commercial Street
North Andover,MAO 1845 Raynham,MA 02767
Phone: Fax: e-mail: Phone:(508)_880-0233 Fax:(508)880-7232 e-mail:
INSTALLATION INFORMATION
Model No. Serial No. Date of Installation Date of last pump out
MicroFAST.5 20951 1/11/2002 5/1/2004
EQUIPMENT YES NO MAINTENANCE PERFORMED AND COMMENTS
Electrical Panel(s)
Visual Alarm Operating x
Audio Alarm Operating x
(if present)
Blower(s)
Air Inlet Filter Clean x
Blower Hood Vents Clear x
Excessive Noise x
Excessive Vibration x
Treatment unit(s)
Unusual Odor x
Pumpout Required x
Primary Settling Zone 16"
Aerobic Treatment Zone 14"
EFFLUENT(optional) LIMIT RESULT
Estimated Daily Flow 440 gpd
pH(Standard Units) 6
Color Brown
Temperature 59
Odor Earthy
Comments:Pumps and floats have been inspected and are operational.
TECHNICIAN SERVICE DATE
Michael Moreau 4/3/15