Loading...
HomeMy WebLinkAboutCorrespondence - 385 RALEIGH TAVERN LANE 1/1/2011 G�U•CC,Jr������'f U��=�%�it��?ZF.'�1�7���.1'/CiUit:C.°.C',4� �i1Z2'ae 44 Commercial Street Raynham,MA 02767 Tel: (5089 233 Fax: (50 i ( I November 11, 2011 f K� li North Andover Board of Health 1600 Osgood Street North Andover, MA 01845 Attention: Health Agent Reference: FAST° Wastewater Treatment System- Serial Number: 20951 Attached please find the Field Inspection & Service Report with field test results for services performed on 10-18-11 at the property of Robert Lynch located at 385 Raleigh Tavern Lane,North Andover, MA. Please call if you have any questions or require additional information. Sincerely, V�� � �, Wastewater Treatment Services, Inc. Service Department Enclosures Copy to: Robert Lynch Massachusetts DEP Massachusetts Department of Environmental Protection Bureau of Resource Protection -Title 5 DEP Approved Inspection and O&M Form for Title 5 I/A Treatment and Disposal Systems 15763 A. Installation Robert Lynch Owner 385 Raleigh Tavern Lane Facility Street Address North Andover 01845 City Zip Mailing address of owner, if different: 385 Raleigh Tavern Lane Street Address/PO Box: North Andover MA 01845 City State Zip Telephone Number B. Authorized Service Provider Wastewater Treatment Services Inc. O&M Firm 44 Commercial Street Street Address Raynham MA 02767 City State Zip 508-880-0233 Telephone Number David Zavelle 12920 Certified Operator Name Certification Number C. Facility/System Information 20951 Bio-Microbics, Inc. MicroFAST .5 DEP ID Manufacturer ID Model Number 1/11/2002 1/11/2002 Installation Date Start of Operation Approval Type: [] General [] Provisional [] Piloting [x] Remedial Seasonal Residence—used less than 6 mo./year: []Yes [x] No D. Operating Information 10-18-11 Inspection Date Previous Inspection Date Pumping Recommended []Yes [x] No Sludge Depth(to be checked yearly) 1 Massachusetts Department of Environmental Protection Bureau of Resource Protection -Title 5 DEP Approved Inspection and O&M Form for Title 5 I/A Treatment and Disposal Systems 15763 E. Field Testing Field Inspection: Color: (] gray [] brown [x]clear (]turbid [] Other(specify): Odor: [] musty [x] earthy [] moldy [] offensive [] turbid Effluent Solids: [x] no [] some pH 7 SU DO 6.65 mg/L Turbidity 9.11 NTU 6 to 9 2 or greater 40 or less Should a Remedial or General Use system fail the Field Testing, effluent samples shall be collected per Standard Methods and analyzed for BOD and TSS. F. Sampling Information Samples Taken: [] Influent [] Effluent Commercial systems or systems with a design flow of 2000 gpd and greater, and General Use nitrogen reducing systems: 440 gpd Parameters sampled: Influent: [] pH [] BOD [] CBOD []TSS []TKN [] Nitrate [] Nitrite [] Phosphorus [] Spec. Cond. []Ammonia []Alkalinity [] Oil Grease []VOC [] Fecal Coliform Effluent. [] pH [] BOD [] CBOD []TSS []TKN [] Nitrate [] Nitrite [] Phosphorus [] Spec. Cond. []Ammonia []Alkalinity [] Oil Grease []VOC [] Fecal Coliform G. Inspection and Maintenance Description of any maintenance performed since previous inspection &during this inspection: Cleaned Filter Checked Splash Recycle Notes and Comments: Alarm not accessible. 2 Massachusetts Department of Environmental Protection Bureau of Resource Protection -Title 5 DEP Approved Inspection and O&M Form for Title 5 I/A Treatment and Disposal Systems 15763 H. Certification I certify: I have inspected the sewage treatment and disposal system at the address above, have conducted the required Field Testing and/or sample collection in accordance with Standard Methods, have completed this report and the attached technology operation and maintenance checklist, and the information reported is true, accurate, and complete as of the time of the inspection. I am a Massachusetts certified operator in accordance with 257 CMR 2.00. 10-18-11 Operator Signature Date System owner must submit this report, technology O&M checklist, and any required sampling results to the local board of health and DEP as follows for each inspection performed: Remedial Use—by January 31 st of each year for the previous calendar year Piloting Use-within 45 days of inspection date Provisional Use— by March 31 th of each year for the previous 12 months General Use—by September 30th of each year for the previous 12 months Send to: Department of Environmental Protection Attention: Title 5 Program One Winter Street, 6th Floor Boston, MA 02108 3 S i "R' ,,,{ - 8450 Cole Parkway, Shawnee, KS 66227, Phone 913-422-0707, Fax 913-422-0808 e-mail:onsite fbiomicrobics.com, www.biomicrobics.com, 800-753-FAST(3278) FIELD INSPECTION & SERVICE REPORT For Bio-Microbics Single Home FAST'System 15763 INSTALLATION AUTHORIZED SERVICE PROVIDER Installation Address: 385 Raleigh Tavern Lane Name:Wastewater Treatment Services,Inc. North Andover,MA 01845 Owner Name:Robert Lynch Mail Address: 385 Raleigh Tavern Lane Mail Address: 44 Commercial Street North Andover,MA 01845 Raynham,MA 02767 Phone: Fax: e-mail: Phone:(508)880-0233 Fax:(508)880-7232 e-mail: INSTALLATION INFORMATION Model No. Serial No. Date of Installation Date of last pump out MicroFAST.5 20951 1/11/2002 5/1/2004 EQUIPMENT YES NO MAINTENANCE PERFORMED AND COMMENTS Electrical Panel(s) Visual Alarm Operating N/A Audio Alarm Operating (if present) Blower(s) Air Inlet Filter Clean x Blower Hood Vents Clear x Excessive Noise x Excessive Vibration x Treatment unit(s) Unusual Odor x Pumpout Required x Primary Settling Zone Aerobic Treatment Zone EFFLUENT(optional) LIMIT RESULT Estimated Daily Flow 440 gpd pH(Standard Units) 7 Color Clear Temperature 67 Odor Earthy Comments:Alarm not accessible. TECHNICIAN SERVICE DATE David Zavelle 10-18-11