Loading...
HomeMy WebLinkAboutInspection - 369 SALEM STREET 2/11/2011 (2) 44 Commercial Street Raynham,MA 02767 Tel: (508)880-0233 Fax: (508)880-7232 September 30,2011 North Andover Board of Health 1600 Osgood Street North Andover, MA 01845 Attention: Health Agent Reference: FAST' Wastewater Treatment System- Serial Number: SHF13 Attached please find the Field Inspection& Service Report with field test results for services performed on 9-13-11 at the property of Amit Banerji located at 369 Salem Street,North Andover, MA. Please call if you have any questions or require additional information. Sincerely, e�?l� 7�- � Wastewater Treatment Services, Inc. Service Department Enclosures Copy to: Amit Banerji Massachusetts DEP Massachusetts Department of Environmental Protection Bureau of Resource Protection -Title 5 DEP Approved Inspection and O&M Form for Title 5 I/A Treatment and Disposal Systems 16686 A. Installation Amit Baner]i Owner 369 Salem Street Facility Street Address North Andover 01845 City Zip Mailing address of owner, if different: 369 Salem Street Street Address/PO Box: North Andover MA 01845 City State Zip 978 557 9154 Telephone Number D. Authorized Service Provider Wastewater Treatment Services, Inc. O&M Firm 44 Commercial Street Street Address Raynham MA 02767 City State Zip 508-880-0233 Telephone Number David Zavelle 12920 Certified Operator Name Certification Number C. Facility/System Information SHF13 Bio-Microbics, Inc. Single HomeFAST.9 DEP ID Manufacturer ID Model Number 9/4/1998 9/4/1998 Installation Date Start of Operation Approval Type: [] General [] Provisional [] Piloting [x] Remedial Seasonal Residence—used less than 6 mo./year: []Yes [x] No D. Operating Information 9-13-11 Inspection Date Previous Inspection Date " Pumping Recommended []Yes [x] No Sludge Depth(to be checked yearly) 1 Massachusetts Department of Environmental Protection LlBureau of Resource Protection -Title 5 DEP Approved Inspection and O&M Form for Title 5 I/A Treatment and Disposal Systems 16686 E. Field Testing Field Inspection: Color: [] gray [] brown [x] clear []turbid [] Other(specify): Odor: [] musty [x] earthy [] moldy []offensive [] turbid Effluent Solids: [x] no []some pH 7 SU DO 5.85 mg/L Turbidity 5.71 NTU 6 to 9 2 or greater 40 or less Should a Remedial or General Use system fail the Field Testing, effluent samples shall be collected per Standard Methods and analyzed for BOD and TSS. F. Sampling Information Samples Taken: [] Influent [ ] Effluent Commercial systems or systems with a design flow of 2000 gpd and greater, and General Use nitrogen reducing systems: 440 gpd Parameters sampled: Influent. [] pH [] BOD [] CBOD []TSS [J TKN [] Nitrate [] Nitrite [] Phosphorus [] Spec. Cond. []Ammonia []Alkalinity [] Oil Grease []VOC [] Fecal Coliform Effluent: [] pH [] BOD [] CBOD []TSS []TKN [] Nitrate [] Nitrite [] Phosphorus [] Spec. Cond. []Ammonia []Alkalinity [] Oil Grease []VOC [] Fecal Coliform G. Inspection and Maintenance Description of any maintenance performed since previous inspection & during this inspection: Cleaned Filter Checked Splash Recycle Notes and Comments: Alarm not accessible. 2 Massachusetts Department of Environmental Protection Bureau of Resource Protection -Title 5 DEP Approved Inspection and O&M Form for Title 5 I/A Treatment and Disposal Systems 16686 H. Certification I certify: I have inspected the sewage treatment and disposal system at the address above, have conducted the required Field Testing and/or sample collection in accordance with Standard Methods, have completed this report and the attached technology operation and maintenance checklist, and the information reported is true, accurate, and complete as of the time of the inspection. I am a Massachusetts certified operator in accordance with 257 CMR 2.00. 9-13-11 Operator Signature Date System owner must submit this report, technology O&M checklist, and any required sampling results to the local board of health and DEP as follows for each inspection performed: Remedial Use—by January 31 st of each year for the previous calendar year Piloting Use -within 45 days of inspection date Provisional Use— by March 31 th of each year for the previous 12 months General Use—by September 30th of each year for the previous 12 months Send to: Department of Environmental Protection Attention: Title 5 Program One Winter Street, 6th Floor Boston, MA 02108 3 e p N z2.is, _ T'14 6 it N P O R.R 7�E U 8450 Cole Parkway, Shawnee, KS 66227, Phone 913-422-0707, Fax 913-422-0808 e-mail:onsite .biomicrobics.com, www.biomicrobics.com, 800-753-FAST(3278) FIELD INSPECTION & SERVICE REPORT For Bio-MicNobics Single Home FAST'System 16686 INSTALLATION AUTHORIZED SERVICE PROVIDER' Installation Address: 369 Salem Street Name:Wastewater Treatment Services,Inc. North Andover,MA 01845 Owner Name:Amit Banerji Mail Address: 369 Salem Street Mail Address: 44 Commercial Street North Andover,MA 01845 Raynham,MA 02767 Phone:978 557 9154 Fax: e-mail: Phone:(508)880-0233 Fax:(508)880-7232 e-mail: INSTALLATION INFORMATION Model No. Serial No. Date of Installation Date of last pump out Single HomeFAST.9 SHF13 9/4/1998 12/2010 EQUIPMENT YES NO MAINTENANCE PERFORMED AND COMMENTS Electrical Panel(s) Visual Alarm Operating N/A Audio Alarm Operating (if present) Blower(s) Air Inlet Filter Clean x Blower Hood Vents Clear x Excessive Noise x Excessive Vibration x Treatment unit(s) Unusual Odor x Pumpout Required x Primary Settling Zone Aerobic Treatment Zone EFFLUENT(optional) LIMIT RESULT Estimated Daily Flow 440 gpd pH(Standard Units) 7 Color Clear Temperature 72 Odor Earthy Comments:Alarm not accessible. TECHNICIAN SERVICE DATE David Zavelle 9-13-11