Loading...
HomeMy WebLinkAboutCorrespondence - 61 WINDSOR LANE 2/8/2005 TOWN OF NORTH ANDOVER Office of COMMUNITY DEVELOPMENT AND SERVICES HEALTH DEPARTMENT 400 OSGOOD STREET NORTH ANDOVER, MASSACHUSETTS 01845 �SS9CHUS�R Susan Y. Sawyer,REHS/RS 978.688.9540—Phone Public Health Director 978.688.9542—FAX February 8,2005 Richard Glover 61 Windsor Lane North Andover,MA 01845 RE: Subsurface Sewage Disposal System Plan for 61 Windsor Lane,Map 106D,Lot 66 Dear Mr. Glover, The North Andover Board of Health has completed review of the septic system design plans for the above referenced property submitted on your behalf by New England Engineering Services dated December 23,2004;Final Revision dated February 4,2005,and received by this office on February 4,2005. The design has been approved for use in the construction of an upgrade onsite septic system. This approval is valid for three years from the date of this letter and during this time a licensed septic system installer must obtain a permit and complete this work,and a Certificate of Compliance must be endorsed by the installer,designer and the Town of North Andover. This approval is subject to the following conditions: 1. If site conditions are found in the field to be different from those indicated on the design plan and/or soil evaluation,the originally issued Disposal System Construction Permit is void, installation shall stop,and the applicant shall reapply for a new Disposal Systems Construction Permit(3 10 CMR 15.020(1)). 2. It is the responsibility of the applicant and/or the applicant's septic system designer,septic system installer or other representative to ensure that all other state and municipal requirements are met. These may include review by the Conservation Commission,Zoning Board,Planning Board,Building Inspector, Plumbing Inspector and/or Electrical Inspector. The issuance of a Disposal System Construction Permit shall not construe and/or imply compliance with any of the aforementioned requirements. 3. The plan does not call for installation of a septic tank effluent filter but one is recommended. Please be advised that only certain brands of filters are permitted for use in Massachusetts and each is required to follow certain approval criteria. Your designer or installer should work with you to assure a licensed brand is selected for use, if you choose to install one. Your effort to provide a properly functioning septic system for your dwelling is greatly appreciated. The Health Department may be reached at 978-688-9540 with any questions you might have. Sincerely, Susan Y. Sawyer,REHS/RS Public Health Director encl: List of licensed septic system installers cc: New England Engineering Services file 'YOWN OF NORTH ANDOVER Office of COMM UNITYI)EVELOPMENTA AN SERVICES HEAL"I'll DEPAR"17MEN"I' 27 Cf 1ARLES S1 REE1,T Nowrfi ANDOVER, MASSAC14(,JSE1-'TS 01845 CHI ' Susan Y. Sawyer, REIIS/RS 978.688.9540 Phone ftbfic Health Director 978.688.9542 FAX January 28, 2005 Benjamin Osgood, P.E. New England Engineering Services, Inc. 60 Beechwood Drive North Andover, MA 01845 Re: Subsurface Sewage Disposal System Plan for 61 Windsor Lane, Map 106D, Lot 66 Dear Mr. Osgood: The proposed septic system design plans for the above site dated December 23, 2004 and received on December 28, 2004 has been reviewed. Unfortunately, it cannot be approved until the following items are corrected. The specific section in Title 5: 310 CMR 15.000, or North Andover regulation that is not met by this design follows each item. 1. The soils shown do not specify that the C-horizon was a gravelly Sandy Loam. Field notes show 50% aggregate, of which— 10% were boulders. -220(4)(h) 2. Please specify that the septic tank shall be tested for watertightness—both for infiltration and leaking. If tank cannot be made watertight, it must be replaced. Also, if the tank is not 1,500 gallon, it will have to be either replaced or a variance requested. Additionally, you might wish to consider using an effluent filter in the septic tank. Please feel free to contact the office with any questions you may have. We look forward to working with you to obtain a septic system which will be in compliance with all regulations and assure protection of public health and the environment of North Andover. Sincerely,,,, Susan Y. Sawyer, REDS/RS Public Health Director cc: Owner File Page 1 of 1 elle hi ie, Pamela From: Andrew McBrearty [amcbrearty @millriverconsulting.com] Bent: Friday, January 28, 2005 2:20 PM To: info@millriverconsulting.com; 'Susan Sawyer'; Pamela Dellechiaie Cc: 'Lisa LeVasseur(E-mail)'; mgrant @townofnorthandover.com Subject: 61 Windsor Lane Sue & Pam, Here is the plan review for 61 Windsor Lane. I am including both an approval and disapproval letter. The soil test data on the plan does not show the large amount of aggregate found during testing, and this would be an important piece of information for an installer to know when preparing bids. I'd rather have a home owner know ahead of time that excavation will (could) be more expensive because of the number of stones that will be encountered, and will have to be removed if found during preparation of the bed bottom. There is no specific note about verification of the watertightness of the existing septic tank. I have included this in both letters, as it is crucial to the system. We have had issues with re-used tanks being undersized, so I also have a note for this as well (replace or variance request required). thanks, -andy Andrew McBrearty, Project Manager Mill River Consulting Septic System Management Services 2 Blackburn Center Gloucester, MA 01930-2259 ph: 978-282-0014 or 1-800-377-3044 fax: 978-282-0012 www,mil lri\rercorisLiltir:tg.coM aiiiebi'earty(�z),rii it lrivei°corisrIltirtg.corrn 2/2/2005 ....,.................... �.._. .� NEW ENGLAND ENGINEERING SERVICES December 27, 2004 Susan Sawyer North Andover Board of Health 400 Osgood Street North Andover, MA 01845 Re: 61 Windsor Lane, North Andover Septic System Design Dear Susan, The following plans and enclosures for the above referenced property are being submitted for approval. 1, (3) Copies of the Septic System Design Plaids. 2. (1) Copy of the Form 11 Soil Evaluator Sheets. 3. (1) Copy of the Form 12 Percolation Test. 4. (1) Check for payment of the Town approval fee. If you have any comments or questions please do not hesitate to contact this office. Sincerely, Steven I . Pouliot Project Manager 60 BEECHWOOD DRIVE;-NORTH ANDOVE R, MA 01845-( l8)686-1768-(888)359...7615-F-AX(978)685-1099 Town of North Andover HE'ALT111 DEPARTMENT 27 Charles Street North Andover,MA 01845 978.688.9540 healtlydeoWmina rrorthandoverecorra SEPTIC PLAN SUBMITTAL FORM r , fi DATE OF SUBMISSION: Z,2'/'z ,,,2'/f'z 7 SITE LOCATION: L ENGINEER: NEW PLANS: YES $225.00/Plan _ Check#: (Includes 1' and one Re-Review Only) REVISED PLANS: YES $75.00/Plan Check#: SITE EVALUATION FORMS INCLUDED: CYES.? NO LOCAL UPGRADE FORM INCLUDED: YES ( NO-) Telephone#: )`'r-, Fax#: '.1 E-mail: HOMEOWNER NAME: I �;.'� Al i 'r.:`� ,����I"tl-- y ,'V s�'t OFFICE USE ONLY When the submission is complete(including check): 1. Date stamp plans and letter 2. """ Complete and attach Receipt 3. ° . Copy File; Forward to Consultant 4. Enter on.Log Sheet and Database NEW ENGLAND ENGINEERING SERVICES February 4, 2005 Susan Sawyer North Andover Board of Health 400 Osgood Street North Andover, MA O1 845 Re: 61 Windsor Lane, North Andover FEB t Septic System Plan Re-Submittal TOWN OF NORTH ANDOVER u Dear Susan: HEALTH.DFPAf mmIMEN b � The following plans for the above referenced property are being re-submitted for review and approval, The new septic design plans have been revised to reflect the comments in your letter dated January 28, 2005. The following changes have been addressed: 1. The soils shown do not specify the Glayer being a gravelly sandy loam. The plans now reflect the appropriate soil texture. 2. Existing tank should specify being tested for water tightness, or being replaced. Existing septic tank to be replaced by a new 1500 gallon septic tank, Enclosed are (3) copies of the revised septic design plans. Please contact this office with any questions or concerns. Sincerely, All Thomas Hector Project Engineer 60 BEECHWOOD DRIVE-NORTH ANDOVER, MA 01845-(976)686-1768—(888)359-7645- FAX(978)685-1099