HomeMy WebLinkAboutCorrespondence - 61 WINDSOR LANE 2/8/2005 TOWN OF NORTH ANDOVER
Office of COMMUNITY DEVELOPMENT AND SERVICES
HEALTH DEPARTMENT
400 OSGOOD STREET
NORTH ANDOVER, MASSACHUSETTS 01845
�SS9CHUS�R
Susan Y. Sawyer,REHS/RS 978.688.9540—Phone
Public Health Director 978.688.9542—FAX
February 8,2005
Richard Glover
61 Windsor Lane
North Andover,MA 01845
RE: Subsurface Sewage Disposal System Plan for 61 Windsor Lane,Map 106D,Lot 66
Dear Mr. Glover,
The North Andover Board of Health has completed review of the septic system design plans for the above referenced
property submitted on your behalf by New England Engineering Services dated December 23,2004;Final Revision
dated February 4,2005,and received by this office on February 4,2005.
The design has been approved for use in the construction of an upgrade onsite septic system. This approval is valid
for three years from the date of this letter and during this time a licensed septic system installer must obtain a permit
and complete this work,and a Certificate of Compliance must be endorsed by the installer,designer and the Town of
North Andover.
This approval is subject to the following conditions:
1. If site conditions are found in the field to be different from those indicated on the design plan and/or soil
evaluation,the originally issued Disposal System Construction Permit is void, installation shall stop,and the
applicant shall reapply for a new Disposal Systems Construction Permit(3 10 CMR 15.020(1)).
2. It is the responsibility of the applicant and/or the applicant's septic system designer,septic system installer
or other representative to ensure that all other state and municipal requirements are met. These may include
review by the Conservation Commission,Zoning Board,Planning Board,Building Inspector, Plumbing
Inspector and/or Electrical Inspector. The issuance of a Disposal System Construction Permit shall not
construe and/or imply compliance with any of the aforementioned requirements.
3. The plan does not call for installation of a septic tank effluent filter but one is recommended. Please be
advised that only certain brands of filters are permitted for use in Massachusetts and each is required to
follow certain approval criteria. Your designer or installer should work with you to assure a licensed brand
is selected for use, if you choose to install one.
Your effort to provide a properly functioning septic system for your dwelling is greatly appreciated. The Health
Department may be reached at 978-688-9540 with any questions you might have.
Sincerely,
Susan Y. Sawyer,REHS/RS
Public Health Director
encl: List of licensed septic system installers
cc: New England Engineering Services
file
'YOWN OF NORTH ANDOVER
Office of COMM UNITYI)EVELOPMENTA AN SERVICES
HEAL"I'll DEPAR"17MEN"I'
27 Cf 1ARLES S1 REE1,T
Nowrfi ANDOVER, MASSAC14(,JSE1-'TS 01845 CHI '
Susan Y. Sawyer, REIIS/RS 978.688.9540 Phone
ftbfic Health Director 978.688.9542 FAX
January 28, 2005
Benjamin Osgood, P.E.
New England Engineering Services, Inc.
60 Beechwood Drive
North Andover, MA 01845
Re: Subsurface Sewage Disposal System Plan for 61 Windsor Lane, Map 106D, Lot 66
Dear Mr. Osgood:
The proposed septic system design plans for the above site dated December 23, 2004 and
received on December 28, 2004 has been reviewed. Unfortunately, it cannot be approved until
the following items are corrected. The specific section in Title 5: 310 CMR 15.000, or North
Andover regulation that is not met by this design follows each item.
1. The soils shown do not specify that the C-horizon was a gravelly Sandy Loam. Field
notes show 50% aggregate, of which— 10% were boulders. -220(4)(h)
2. Please specify that the septic tank shall be tested for watertightness—both for
infiltration and leaking. If tank cannot be made watertight, it must be replaced. Also,
if the tank is not 1,500 gallon, it will have to be either replaced or a variance requested.
Additionally, you might wish to consider using an effluent filter in the septic tank.
Please feel free to contact the office with any questions you may have. We look forward to
working with you to obtain a septic system which will be in compliance with all regulations and
assure protection of public health and the environment of North Andover.
Sincerely,,,,
Susan Y. Sawyer, REDS/RS
Public Health Director
cc: Owner
File
Page 1 of 1
elle hi ie, Pamela
From: Andrew McBrearty [amcbrearty @millriverconsulting.com]
Bent: Friday, January 28, 2005 2:20 PM
To: info@millriverconsulting.com; 'Susan Sawyer'; Pamela Dellechiaie
Cc: 'Lisa LeVasseur(E-mail)'; mgrant @townofnorthandover.com
Subject: 61 Windsor Lane
Sue & Pam,
Here is the plan review for 61 Windsor Lane. I am including both an approval and disapproval letter.
The soil test data on the plan does not show the large amount of aggregate found during testing, and this
would be an important piece of information for an installer to know when preparing bids. I'd rather have
a home owner know ahead of time that excavation will (could) be more expensive because of the
number of stones that will be encountered, and will have to be removed if found during preparation of
the bed bottom.
There is no specific note about verification of the watertightness of the existing septic tank. I have
included this in both letters, as it is crucial to the system. We have had issues with re-used tanks being
undersized, so I also have a note for this as well (replace or variance request required).
thanks,
-andy
Andrew McBrearty, Project Manager
Mill River Consulting
Septic System Management Services
2 Blackburn Center
Gloucester, MA 01930-2259
ph: 978-282-0014 or 1-800-377-3044
fax: 978-282-0012
www,mil lri\rercorisLiltir:tg.coM
aiiiebi'earty(�z),rii it lrivei°corisrIltirtg.corrn
2/2/2005
....,....................
�.._. .�
NEW ENGLAND ENGINEERING SERVICES
December 27, 2004
Susan Sawyer
North Andover Board of Health
400 Osgood Street
North Andover, MA 01845
Re: 61 Windsor Lane, North Andover
Septic System Design
Dear Susan,
The following plans and enclosures for the above referenced property are being submitted
for approval.
1, (3) Copies of the Septic System Design Plaids.
2. (1) Copy of the Form 11 Soil Evaluator Sheets.
3. (1) Copy of the Form 12 Percolation Test.
4. (1) Check for payment of the Town approval fee.
If you have any comments or questions please do not hesitate to contact this office.
Sincerely,
Steven I . Pouliot
Project Manager
60 BEECHWOOD DRIVE;-NORTH ANDOVE R, MA 01845-( l8)686-1768-(888)359...7615-F-AX(978)685-1099
Town of North Andover
HE'ALT111 DEPARTMENT
27 Charles Street
North Andover,MA 01845
978.688.9540
healtlydeoWmina rrorthandoverecorra
SEPTIC PLAN SUBMITTAL FORM
r , fi
DATE OF SUBMISSION: Z,2'/'z
,,,2'/f'z 7
SITE LOCATION: L
ENGINEER:
NEW PLANS: YES $225.00/Plan _ Check#:
(Includes 1' and one Re-Review Only)
REVISED PLANS: YES $75.00/Plan Check#:
SITE EVALUATION FORMS INCLUDED: CYES.? NO
LOCAL UPGRADE FORM INCLUDED: YES ( NO-)
Telephone#: )`'r-, Fax#: '.1
E-mail:
HOMEOWNER NAME: I �;.'� Al i 'r.:`� ,����I"tl-- y ,'V s�'t
OFFICE USE ONLY
When the submission is complete(including check):
1. Date stamp plans and letter
2. """ Complete and attach Receipt
3. ° . Copy File; Forward to Consultant
4. Enter on.Log Sheet and Database
NEW ENGLAND ENGINEERING
SERVICES
February 4, 2005
Susan Sawyer
North Andover Board of Health
400 Osgood Street
North Andover, MA O1 845
Re: 61 Windsor Lane, North Andover FEB t
Septic System Plan Re-Submittal
TOWN OF NORTH ANDOVER
u
Dear Susan: HEALTH.DFPAf mmIMEN b
�
The following plans for the above referenced property are being re-submitted for review and
approval, The new septic design plans have been revised to reflect the comments in your letter
dated January 28, 2005. The following changes have been addressed:
1. The soils shown do not specify the Glayer being a gravelly sandy loam. The plans
now reflect the appropriate soil texture.
2. Existing tank should specify being tested for water tightness, or being replaced.
Existing septic tank to be replaced by a new 1500 gallon septic tank,
Enclosed are (3) copies of the revised septic design plans. Please contact this office with any
questions or concerns.
Sincerely,
All
Thomas Hector
Project Engineer
60 BEECHWOOD DRIVE-NORTH ANDOVER, MA 01845-(976)686-1768—(888)359-7645- FAX(978)685-1099