Loading...
HomeMy WebLinkAboutCorrespondence - 502 WINTER STREET 7/1/2008 W "'� �uiiumoiW R: .. pP F h Cm II" PUBUK 11111i!ALTh [A[.xa JIl`tME1147 (osrn=OY hvdopn�ed tG xu roar July 1,2008 David kindred PO Box 531 North Andover, MA 01 845 RE: Subsurface Sewage Disposal Systern Plan for lot 3A. (502) Winter Strect, rnap 104A, Parcel 78,North Andover, MA. Dear Mr. Kindred, The North Andover Board of Health has completed the review of the septic system design plaris, for the above referenced grope°ty. These plans dated June 11, 2008, received June 18, 2008, have been approved for a four(4) bedroom, maximum nine-room horde. In accordance with local subsurface disposal regulations"Acceptable plans and any variances shall expire two years from the date approved unless construction on the lot has begun". During this time a licensed septic system installer mast obtain a perrrrit and complete this work, and a Certificate of Compliance must be endorsed by the installer, designer and the Town of North Andover. The following;variances were approved at the June 25, 2008 Board of Health meeting. - Sec 5.02 The proposed distance between a wetland and the leaching;facility is '71 feet Secton 9.01 The proposed area of the Eljen"G Sly" leaching,bed is 513 instead of the required 900 sq. feet. This approval is subject to the followings conditions: 1. prior to receiving;a building;permit or installation permit:,the applicant must provide complete floor plans of the new home. Including; basements and attics. 2. Prior to receiving;art installation permit" the applicant must,provide a foundation plan in 1"=20" scale to overlay on the septic plan. 3. If site conditions are found in the field to be different from those indicated on the design plan arid/or soil evaluation, the originally issued Disposal System Construction Permit is void, installation shall stop, and the applicant shall reapply for a new Disposal Systerns C;onstrr,rction Permit(3 10 CMR 15.020(l)). Phon ie 978,688,9540 Fox 974.444,4477 Web s�u�x.Gx u�xl��aso II��o�on�9¢��rx�o�roo�m 4. It is the responsibility of the applicant and/or the applicant's septic systeirt designer, septic system installer or other representative to crisure that all other state and municipal requirements are met. These may include review by the Conservation Conn-mission, Zoning Board, Planning Board, Building Inspector, Plumbing Inspector and/or Electrical Inspector. The issuance of a Disposal System Construction Pemlit shall not construe and/or imply cornplianee with any of the aforementioned requirements. Your effort to provide as properly functioning septic system for your dwelling is greatly appreciated. Tbc Health Department may be reached at 978-688-9540 with any questions you may have. Sincerely, 'Sus Y. Sa,*yer, RE VRS Public Health Director Encl: list of licensed septic system installers Cc: Christiansen and Sergi Prof. Engineers and Land Surveyors MO 0p good Staeet, NoOh hdove� , Musso�hsefls 01845 Mm� e MA88.9540 Fox 978.688.8476 Web Marchionda UTH & Associates, L.P. �Engineering and Planning Consultants 0$ DOVER June 16, 2008 cNT a-a EN North Andover Board of Health 1600 Osgood Street Suite 2-36 North Andover, MA 01845 RE: 502 Winter Street (Map 104A, Parcel 78) Sanitary Septic Disposal System Dear Board Members: We are submitting for your review a revised Sanitary Septic Disposal System Design for the property at 502 Winter Street. The original design was submitted to you last December and was followed by a review response letter fronj the Public Health Director dated; 1/24/2008. The revised plan has addressed the concerns stated in the review and we offer the following comments to each of the items; 1. Please provide a complete profile of the system to scale (NA 8.02c). A "to scale" systertt profile has been added to the plan. 2. Please provide a note on the plan listing all variance requests being sought (220(4)). North Andover routinely does not provide variances to new construction unless the erigineer proposes a systeryj that will guarantee equal protection to the environment. Please address issue. A list of the variances required from the North.Andover Septic Regulations have been added to the plan. They are listed in Note#16 of the General Notes. Two variances are being requested witli this plan. The closest distance between the edge of a wetland and the leaching area is proposed to be 71 feet. Section.5.02 requires the distance to be 100 feet. The leaching area.foot print proposed is S13 S.F. Section. 9.01 requires a ininirnunz of 900 S.F. It should be noted that we are not seeking any vari.an.ces from the Massachusetts "Title V" Environ.rnental Code, 310 CMR 15.000. The revised plan proposes the use of a Elien "In-Drain." system which utilizes Geotextile Sand Filters. T Iris technology has been approved for general use by Mass. D.E.P. The technology provides unproved treatment to septic tank �ffluertt front traditional soil absorption systems. Testing on the effectiveness of the systern was completed at the Massachusetts Alternative Septic System Test Center and has been enclosed for your review. The system as shown has been sized as reconanended by the approved systent design guidelines. Based 62 Montvale Avel)ue Tel: ('781) 4311-6121 Suite I Fax: (781) 438-1654 website: http://www.marchionda.com Stoneham,MA 02180 Email: rYmail @inarchiorltla.com Marchionda & Associates, L.P. Engineering and Planning Consultants Oil this inforrnat%on the are confident that the systemn as design will provide unproved treatment over a smaller footprint than the traditional design standards for leach fields or beds. 3. Mote#10 in the General Notes section indicates there are no wetlands within 100 feet of the proposed SAS however, the SAS is located 66 feet from the wetlands on the site plan. Please revise as necessary. Note#10 of the general motes has been revised asreconznaended. 4. Please provide a statement indicating the design will not accommodate the use of a garbage grinder. Note#9 of the general motes has been revised as recon mended. 5. Please provide all distances on the site plan from components and leaching facilities (NA 8.03a-c). Additional, distances have been added to the site plan.. 6. Please specify all connections are to be made watertight (222(3) & (4), NA 11.02). Construction Note#7 has been revised as r-econunended. 7. Please specify all pipe to be laid on a compact firm base on continuous grade in a straight of a line as possible (222(5) & (7)). Construction.Note#19 has been added as reconunended. 8. Please specify all tanks and distribution boxes to be watertight. Construction Note#20 has been added as recontnaended. 9. As depicted an insufficient number of test pits were conducted in the primary disposal area (102(2)). Additional soil observation test holes were viewed and logged on 5122108. The holes ivere ivi.tnessed by the town's consultant. The logs for these pits have been, added to the plains. Two observation test holes have now been located in both the primary disposal area and the reserve disposal areas. Marchionda & Associates, L.P. Engineering and Planning Consultants 10. As depicted an insufficient number of percolation tests were performed in the primary disposal area( 104(4)). The primary and reserve areas have been re-orientated in the area of the percolation. tests. 11. Please include a statement describing why trenchers were not used in the design. A Iajen "In-brain" system ivith Geotextile Sand Filters has been proposed to improve the effluent treatment. 12. Please include the inspection port in the appropriate details. A detail of the proposed inspection port has been added to the typical section. We hope the revised plan has satisfied the board and your staffs concerns. Please do not hesitate to contact us if you have any questions on this matter. Sincerely, Marchionda & Associates, L.P. John A. Bairrows, PE Project Manager Cc: David Kindred DelleChiaie, Pamela From: Jahn Barrows [john @marchionda.com] Sent: Thursday, January 24, 2008 12:47 PM To: DelleChiaie, Pamela Cc: kindred.david @gmail.com; Sawyer, Susan Subject: RE: Plan Review- 502 Winter St. - Disapproval Letter Susan & Pam, We will plan on corning in tonight to get some feedback and direction from the board. Thanks, John John A. Barrows, P.E. Marchionda & Associates, L.P. This electronic mail message and any files transmitted with it are confidential and intended solely for the use of the individual or entity to whom addressed. You acknowledge that by opening the electronic documents attached hereto that you agree with the terms of the disclaimer/waiver, the statement of ownership, and other matter as documented on Marchionda Associates`webs ite at http://www.marchionda.com/disclaimer.htm CONFIDENTIALITY NOTICE: This email may contain confidential and privileged material for the sole use of the intended recipient(s). Any review, use, distribution or disclosure by others is strictly prohibited. If you have received this communication in error, please notify the sender immediately by email and delete the message and any file attachments from your. computer. Thank you. -_---Original Message----- From: DelleChiaie, Pamela [mai Ito:pdellech @townofnorthand over,com] Sent: Thursday, January 24, 2008 11:46 AM To: John Barrows Cc: kind red.david @grnail.com; Sawyer, Susan Subject: Plan Review- 502 Winter St. - Disapproval Letter Importance: High Vote: I am sending this on behalf of Susan Sawyer, North Andover health Director Dear John, Please find the attached review of the plan for 502 Winter Street. As we discussed over the phone, the plan proposed does not have any provision as to why the Board of Health should grant the variance. Not to mention the actual variance request is one of 12 missing items. So, the reality is the plan that we have is deficient in many ways and 1 you know that a variance will likely not be approved without remediation of some kind. I would suggest that this plan is not ready to be discussed, however if you want to cone to the meeting tonight just to see if a certain variance would be considered, as in the previous situation, and than come Mack in Feb. for the actual variance that would be ok, Either,way, I will ask for,you to carne in February. Thank you Susan Sawyer, REHS/RS -__--Original Message--­­ From: John Barrows [ ailto:jol°rn 7a,rrrarchiorlda.com] Sent: Wednesday, December 19, 2007 10:16 AM To: DelleChiaie, Pamela Subject: 502 Winter St. Ili loam, Dave Kindred asked that I send you a formal request for a hearing for a septic system variance. Will this letter do the trick? 'Thanks, John John A. Barrows, RE. Marchionda &Associates, L.F. This electronic mail message and any files transmitted with it are confidential and intended solely for the use of the individual or entity to whom addressed. You acknowledge that by opening the electronic documents attached hereto that you agree with the terms of the disclaimer/waiver, the statement of ownership, and other matter as documented orr Marchionda Associates'website at http://www,niarchiorida.com/disclaimer,htm CONFIDENTIAUTY NOTICE: This email may contain confidential and privileged material for the sole use of the intended recipient(s). Any review, use, distribution or disclosure by others is strictly prohibited. It you have received this communication Mn error, please notify the sender immediately by email and delete the message and any file attachments from your computer. "T"hank you. 2 ollJ t} �Iil�ud�rr�I.ir�YIN�I�'"h IQ 11 C (dW01 da a A magBa°i[eering a nd �vtis�1 tlirami?i Nanning t ahr"V"iuu trcants December 13, 2007 North Andover Board of Health 1600 Osgood Street Suite 2-36 North Andover, MA 01845 RE: 502 Winter Street, Sanitary Septic Disposal System Dear Members: On behalf of the applicant David Kindred, we are submitting an application for a Disposal System Construction Permit. Enclosed for your use are three copies of the plan for the Proposed Disposal System along with the appropriate filing fee. The system as designed meets the State Environmental Code, 310 CMR 15.000. Due to the proximity of the proposed leaching area to a Bordering Vegetated Wetland a variance is required to the Town of North Andover's regulations for subsurface disposal of sanitary sewage. Section 5.02 requires that a Leaching Facility be located 100 feet from a wetland. At its closest point the leaching area is proposed to be located 66 feet to the wetland. We would also like permission to use Deep Hole Observations that were performed over two years ago. These holes were performed by a Certified Soil Evaluator and witnessed by Board of Health inspectors. The results of these observations are included on the submitted plans. It should be noted that the North Andover Conservation Commission has approved the location of the proposed leaching facility and the wetland line delineated on the plan and an Order of Conditions has been issued. Please do not hesitate to call should you have any questions. Sincerely, Marchionda & Associates, L.P. John A. Bdrows, PE Project Manager Cc: David Kindred �t,d � tl a (78a ) 438,9654 vwaebsit . lattp://�wrarwvv,rriarci°i� �nd�i.s.rtac �°vi �3ta,m a,.tanriKw, naf A ()2.�8 0 Ernodh �ruruU(� vru a,V,pr:,rar� a.rwwurra Marchionda E nga it"&ew iirey ueand M s a December 19, 2007 F RECEIVED North Andover Board of Health h l� , 1 �007 1600 Osgood Street Suite 2-36 T(IM,1 OF I ll:f:f LTI I'xk; P.G 'J'TNarEN r North Andover, MA 01845 .............. RE: 502 Winter Street, Sanitary Septic Disposal System Dear Board Members: We recently submitted to you a plan and application to construct a Sanitary Septic Disposal System at 502 Winter Street. Due to the proximity of the proposed leaching area to a Bordering Vegetated Wetland a variance is required to the Town of North Andover's regulations. On behalf of the applicant David Kindred, we would like to request a hearing with the Board of Health. Please do not hesitate to call should you have any questions on this matter. Sincerely, Marchionda & Associates, L.P. John A. Barro s, PE Project Manager Cc: David Kindred 62 Moniry aka vc'm°we 1°ark (781) 438,6121 i ,o'flte N Fax: (78n) 438 9654 websfte �ittp//wvvw.a'riaac ice(!) ida.corn � v u.araaeIPawn, MA()21 80 a°�prceV uaaraceN(��k�ouu�ai¢a°r1°acea�aaa�lw�����a�o- � MERRIMACK ENGINEERING SERVICES, INC. ty 1 PROFESSIONAL ENGINEERS 0 LAND SURVEYORS 0 PLANNERS 66 PARK STREET«ANDOVER,MASSACHUSETTS 01 810«TEL(978)475-3555,373-5721 «FAX(978)475-1448«E-MAIL:merreng @aol.com February 8, 2005 Ms. Susan Sawyer Public Health Director Town of North Andover 400 Sutton Street North Andover, MA 01845 FEB 2005 RE: Lot 3A Winter Street TOWN OF N o(j� m'ANE)(:')�°�.r,� ii AL'LH���EPACaI. �lrNI' Dear Ms, Sawyer: Enclosed herewith are three (3) copies of the revised septic plan for the above referenced site. The plan has been revised to address all of your Department's concerns as expressed in the review letter dated August 19, 2002, On July 17, 2003 we also conducted an additional test pit shown as T-3 on the enclosed plans. This test pit was performed in response to your Department's letter dated December 30, 2002. We feel your concerns have been adequately addressed and respectfully request that this matter be placed on your earliest meeting agenda for consideration of the variance request as noted on the plan. Variances are requested from Section 9.02 and 15.211 of the North Andover Board of Health Regulations. We appreciate your prompt attention to this matter. Very truly yours, MER.RIMACK ENGINEERING SERVICES William Dufresne Project Manager cd Enclosure cc: Mr. Mike Gaglione Attorney Mike Newhouse 'YOWN OP' NORT11 ANDOVER Office of SIKRVICES llt�AL`1'11 I)PIT'Al FMI NT 400 OSG001) S,1101"J"T NORTH V,H)OVE'R, OH"v15 Susan V, 8,,m,�Cr, RE11 s/104 97 3s,688,9540 Nwnc,, Public llealtb ffirector 978,688 9542 FAX Bill Dufresne Merrimack Engineering Services 66 Park Street Andover,MA 01810 Re:Lot 3A Winter Street March 4, 2005 Dear Mr. Dufresne, This letter is in regards to your recent revisions to the proposed new home at Lot 3A Winter Street. Per your request you have been placed on the Board of Health meeting agenda for March 24,2005. The meeting will be held at 7:OOPM at the recently renovated town hall, second floor,meeting room. At that meeting your requests for variances will be heard. In addition,this office has identified the following concerns that need to be addressed. 1) The leach field detail shows 3:1 slope away from the wall. As this wall is approximately three feet from the lot line,please indicate how this grading would be achieved or remove notation if it is not applicable. If the wall is higher than four feet the standard versa lock walls require anchoring. This plan shows a 40 ird barrier,however this cannot be placed when a geomembrane is needed for the versa-lok wall would penetrate the membrane.Please adjust the wall details for this specific site and submit the documentation indicating specifications. 2) There must be at lease one original stamped plan 15.220(2) 3) Pleases submit the soil evaluation forms for the soil test mentioned in your submission;T-3 dated July 17, 2005. Please submit revised plans or bring them to the Board of Health meeting. All outstanding items that you may wish to discuss in detail may be addressed at that time. ce ) an Y � r s EHS/RS �a er,R Public Health Director Cc file I F r i �iaf�f tl l; December 30, 2002 ° Bill Dufresne Merrimack Engineering Services 66 Park Street Andover, MA 01810 Re: Lot 3A Winter Street Dear Mr. Dufresne: This letter comes upon review of the proposed septic plan for a new dwelling at Lot 3A Winter Street and particularly your request to use soil tests that are more than three years old. Because this is new construction, and because the percolation rate of 20 minutes per inch does not agree with the stated soil class of 1, your request for a waiver to use outdated soil testing is denied. New testing must be performed in the spring of 2003 with staff from the Health Department. The price for new construction soil testing is $425 as of January 1, 2003. Soil testing will begin in March, depending on weather conditions. Should you have any questions concerning the content of this letter, please contact me. Sincerely, ........... Sandra Starr, R.S., C.H.O. Health Director Cc: Gaglione—owner BOH File