HomeMy WebLinkAboutCertificate of Compliance - 444 SALEM STREET 9/13/2000 TOWN OF NORTH ANDOVER BOARD OF HEALTH CERTIFICATE OF COMPLIANCE DATE OF COMPLIANCE: 9/13/00 This is to certify that the individual subsurface disposal system constructed O or repaired (X) by Mike Reilly at 444 Salem Street has been installed in.accordance with the provisions of Title V of the State Sanitary Code and with the North Andover Board of Health regulations. The Issuance of this certificate shall not be construed as a guarantee that the system will function satisfactorily. Board of Health Inspector TOWN OF NORTH ANDOVER SEWAGE DISPOSAL SYSTEM INSTALLATION CERTIFICATION The u dersigned hereby certify that the Sewage Disposal System ( ) constructed; ( repaired: by L4 _, I located at f;L1 c' " was installed in conformance with the North Andover Board of Health approved plan, System Design Permit# dated , with an approved design flow of--;*XAw2gallons per day. The materials used were in conformance with those specifie on the approved plan; the system was installed in accordance with the provisions of 310 CMR 15.000, Title 5 and local regulations, and the final grading agrees substantially with the approved plan. All work is accurately represented on the As-built which has been submitted to the Board of Health. Bed inspection date: C �I Engineer Represen tive Final inspection date: Engineer RepresentatiAve P Installer: AiU L Lic.#: Date: Design Engineer: AS-BUILT CHECKLIST �✓ LOT NUMBER STREET NAME ASSESSORS MAP & PARCEL NUMBER LOT LINES & LOCATION OF DWELLINGS # (�` LOCATIONS & DIMENSIONS OF SYSTEM INCLUDING RESERVE TIES TO LOT LINES &DWELLING, WELLS a. FROM SEPTIC TANK b. FROM LEACH AREA LOCATIONS OF DEEP HOLES & PERC TESTS ELEVATIONS OF DISPOSAL SYSTEM TOP OF FDN ELEVATION LOCATIONS OF WELLS, DRAINS, WATERCOURSES WITHIN 150' OF SYSTEM LOCATION OF WATER GAS ELECTRIC LINES CABLE DISTANCES FROM CORNERS OF HOUSE TO CENTER OF TANK& D-BOX ORIGINAL STAMP & SIGNATURE IMPERVIOUS AREAS - DRIVEWAYS, ETC. NORTH ARROW LOCATION&ELEVATIONS OF BENCHMARK USED INSPECTION CHECKLIST FOR SEPTIC SYSTEMS Yes �, NO Initials A. Bottom of Bed 1. Excavation to proper depth /f/ 2. With trenches,sides of excavation are beneath B horizon 3. Edge of excavation specified distance from foundation,etc, ti Comments: B. Retaining Wall 1. Wall height and width as speci d 2. Waterproofed 3. Wall minimum 10'to leaching facile 4. Wall meets specifications of plan Comments: C. Building Sewer 1. Pipe diameter minimum 4" 2. Schedule 40 pipe 3. Watertight joints 4. Inlet to tank cemented 5. Slope minimum 0.01 or 1/8"per foot minimum 6. Pipe properly set on compact firm base 7. Pipe laid on continuous grade in straight line 8. Cleanouts precede all change in alignment and grade 9. Manholes at any 90°change 10. 10' minimum offset to water line Comments: D. Septic Tank f 1. Level 2. 1,500 gal minimum 3. Gas baffle present on outlet 4. Manhole to grade 5. Manholes over center and each tee 6. 3-20"manholes 7. Inlet tee minimum 12"under invert 8. Outlet tee minimum 14"under invert 9. Outlet line cemented 10. Air space 3"above tees 11. 2"-3"drop from inlet to outlet 12. Pipe set 13. Compact base with 6"of 1/4"crushed stone under tank 14. Tank is watertight Comments: E. Pump Chamber Yes NO / 1. If separate from tank,compact base with 6"of "st e unde®rneath 2. Minimum 2"pipe to d-box if gravity system 3. 20"access manhole 4. Tank level 5. Watertight 6. Tank size agrees with plan specification 7. Manhole to grade 8. Check valve and bleeder hole present 9. Alarm in building on separate circuit 10. Alarm fiumtions 11. Manual operating switch 12. Pump delivers liquid to d-box Comments: F. Distribution Box 1. D-box level i 2. Minimum 0.1 T'(2")drop from inlet to outlet i 3. Minimum 6"sump 4. Outlet pipes show equal distribution l/ 5. Compact base with 6"of stone beneath box 6. Box is watertight 7. All lines cemented with hydraulic cement 8. Schedule 40 pipe 1/ Comments: G. Soil Absorption system 'J coo e- f e_cv, 1. All stone double-washed-'/. 1 'h" ? -pea stone Bucket test done? 2. Minimum 2".of pea stone above distribution lines / 3. Minimum 6"stone beneath pipe 4. Distribution lines capped or connected together, / U 5. Grading meets 3:1 slope 6. Minimum of 9"of fill graded over system 7. Toe of slope stops minimum 5' from edge of property; if not,then swale. Comments: H. Leach Trenches ' 1. Minimum 2 trenches 2. Length of trenches agree with plan. (Max. length 100') �- 3. Width of trenches agree with plan-Minimum 2';maximum-4'. 4. Vent present if<50 feet or specified E-' r t 5. Distance between trenches minimum 4' and maximum of 6' -= f 6. Minimum distance between trenches 10' 7. Pipe slope minimum 0.005 or 6"per 100' 8. Depth of trenches below outlet invert minimum of 6". a Yes NO 9. Pipes set on stable base. Comments: 1. Leach Field 1. Maximum length of field 100' 2. Pipe slope minimum 0.005 or 6"per 100' 3. Separation between pipe 6'maximum 4. Pipes connected at end 5. Separation between adjacent fields 10'minimum 6. Pipes set on stable base 7. Maximum 4' separation from edge of field to first line 8. Minimum two distribution lines 9. Maximum perc rate 20 mpi Comments: J. Leaching Pits 1. Minimum inlet pipe 4\id 2. Pits of concrete 3. Sidewall between 12"4. Access manholes on e5. Pipes cemented with h Comments: K. Final Grade 1. Slope over soil absorption system minimum 0.02 2. All system components covered by at least 9"soil 3. Cover soil free of stones larger than 6" 4. Grading slopes away from dwelling 5. No areas over system that may pond