HomeMy WebLinkAboutPlans - 70 THISTLE ROAD 2/19/2016 ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3, A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGO EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HOG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. 1 CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(8). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING P01 POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10, MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT PV1 COVER SHEET 313 NEMA 3R, RAINTIGHT PV2 SITE PLAN PV3 STRUCTURAL VIEWS ` PV4 UPLIFT CALCULATIONS INE LICENSE GENERAL NOTES C�i heeHREttach dDIAGRAM GEN #168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION ELEC 1136 MR OF THE MA STATE BUILDING CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. MODULE GROUNDING METHOD: AHJ: North Andover REV BY DATE COMMENTS REVA NAME DATE COMMENTS UTILITY: National Grid USA (Massachusetts Electric) JB-0183485 00 PREMSE0 °ES"IRTION D� CON DENTAL-THE INFORMATION HEREIN JOB NUMBER: �\,Ta CONTAINED SHALL NOT BE USED FOR THE AN, HONG AN RESIDENCE Harold Johnson SolarCit ` BENEFIT OF ANYONE EXCEPT SOLARCITY INC. MOUNIM SY11EH: l j� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mt T C 70 THISTLE RD 6.885 KW PV ARRAY r,\ PART TO OTHERS OUTSIDE THE RECIPIENT'S Comp }Pe ORGANIZATION,EXCEPT IN CONNECTION WITH MODULE& NORTH ANDOVER, MA 01845 24 St.M«tm DHw,Miwn9 2,Ord v HE SALE AND USE THE RESPECTIVE (27) TRINA SOLAR #TSM-255PDO5.18 PACE NAME: SffET: REN DA E MmtawWgh,MA 01752 THE SALE EQUIPMENT,WTiHWT 1HE WRn1QJ INVERTER: T:(650j 638-7028 F:(650j 678-1029 PERMISSION OF SOARClTY'NO sERTER: GE SE5000A—USOOOSNR2 (857) 472-2318 COVER SHEET PV 1 2/18/2016 (B6Bj-SOL-CITY(765-2489) , . ct"- PITCH:36 ARRAY PITCH:36 MPI AZIMUTH:251 ARRAY AZIMUTH:251 MATERIAL:Comp Shingle STORY:2 Stories PITCH:36 ARRAY PITCH:36 MP2 AZIMUTH:251 ARRAY AZIMUTH:251 MATERIAL:Comp Shingle STORY:2 Stories PITCH:36 ARRAY PITCH:36 MP3 AZIMUTH:161 ARRAY AZIMUTH:161 f � MATERIAL:Comp Shingle STORY:2 Stories vEII r AC F' D Front Of House ® LEGEND Inv O (E) UTILITY METER & WARNING LABEL a''�P � O INVERTER W/INTEGRATED DC DISCO o & WARNING LABELS I H. m RIUKI ©® O ST 1 DG DISCONNECT& WARNING LABELS NO'51933iDOD. U B �FOTSTE�` ® AC DISCONNECT& WARNING LABELS O DC JUNCTION/COMBINER BOX &LABELS t `- I >a DISTRIBUTION PANEL&LABELS D LOAD CENTER &WARNING LABELS Digitally signed by Humphrey O DEDICATED PV SYSTEM METER Kariuki STANDOFF LOCATIONS Date:2016.02.18 20:48:54 CONDUIT RUN ON EXTERIOR C _05'��I CONDUIT RUN ON INTERIOR GATE/FENCE 0 HEAT PRODUCING VENTS ARE RED r-� INTERIOR EQUIPMENT IS DASHED L.J SITE PLAN N Scale:3/32"=V W� 01' 10' 21' £ S CONFIDENTIAL-THE INFCRMATICN HEREIN .168 NUMBER: JB-0183485 00 PREMISE OWNER, DESORPTION; DESIGN, CONTAINED SHALL OF BE USED pat THE AN, HONG AN RESIDENCE Harold Johnson ���la BENEFlT OF ANYONE EXCEPT SOLARCnY WC., MOUNTING SYSTEM: ColarCit Nat SHALL IT BE DISCLOSED IN YMOLE at IN Comp Mount Type C 70 THISTLE RD 6.885 KW PV ARRAY i1* Y �',e PART TO OTHEE OUTSIDE IN THE ECnONN T MOD L" NORTH ANDOVER, MA 01845 ORGANIZATION,140SESOLMCITYAND EXCEPT IN CONNECTION NTH 24 St.Mahn D(..Rulidhg 2,Unit it THE SALE AND USE T,THE RESPECTIVE WE (27) TRINA SOLAR TSM-255PD05.18 01752 PERMISSION E0FSOLNT,TY THE 14R177EN DI4FRTER: PAGE NAME: SHEET. BEY: DATE MaHWw028 F; 650) pERMIssOx of saARa v INC.INc. SOLAREDGE SE5000A-USOOOSNR2 (857) 472-2318 SITE PLAN PV 2 2/18/2016 T SOL-6'R-7628 F.(BW�S3WcIty (868)-sa-cm pss-zass) .,da,aty.— F O R RIUKIII ST UOTURAL NO 5193" GiST si N A SiY(E) LBW 4" SIDE VIEW OF MPl NTS (E)4LBW SIDE VIEW OF MP3 NTS MIDI I X-SPACING X-CANTILEVER Y-SPACING Y CANTILEVER NOTES LANDSCAPE1 64" 1 24" ISTAGGERED MP3 X-SPACING X CANTIL ER Y-SPACING Y CANTILEVER NOTES LANDSCAPE', 64 24" STAGGERED RTRArr PORTRAIT 1 48" 1 19" 48" ROOF AZI 25 PITCH 36 STORIES,2 ROOF AZI 2x1O @ 16"CC ARRAY AZI 25, 1 RAFTER I PITCH 36 RAFTER 2x10 @ 16"OC 1161 PITCH 16 ARRAY AZI 6 PETC. - STORIES:2 Comp Shingle C.I. 2x10 @16"OC C.,shin PV MODULE 5/16- BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZED LEVELING FOOT (1)1 LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) L__I HOLE, — (4) @1 POLYURETHANE PILOT HOLE�H ZEP COMP MOUNT C OLYURETHANE SEALANT. si ZED FLASHING C (3) (3) INSERT FLASHING (E) COMP SHINGLE (4) PLAGE MOUNT. 4' 4'-8- (6) (4) Y4' -8'—,' (E) ROOF DECKING u INSTALL LAG BOLT WITH (E)LBW SEALING 5/16" DIA STAINLESS (5) ,WASHER. LOWEST MODULE"SUBSEQUENT MODULES — SIDE VIEW OF MP2 NTs STEEL LAG BOLT LOWEST MO SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH] WITH SEALING WASHER C(6)F BOLT& WASHERS. I (2-1/2- EMBED, MIN) MP2 NGX-CAN A ITILEVER Y-SPACING Y-CANTILEVER NOTES A7 L _ (E) RAFTER 64 2,V' STAGGERED STANDOFF PORTRAIT 1 48" 1 19" RAFTER 2x10 @ 16"OC ROOF AZ 251 PITCH 36 Scale:1 1/2" V ARRAY AZI 251PITCH 36 STORIES:2 C.I. 2x10 @16"OC C—P shingle CONDO TIAL-THE INFORMATION HEREIN -N- JB-0183485 00 PREWSE OVOL DESORPTION: DESIGN: CONTAIN D SHALL NOT BE USED FOR THE AN, HONG AN RESIDENCE Harold Johnson BENEFIT OF ANYONE EXCEPT SOMCITY INC.. WDURTH;SYMM — ;�j""SolarCity NOR SHALL IT BE DISCLOSED IN MOLE OR IN 70 THISTLE RD 6,885 KW PV ARRAY 1� PART To OTHERS THE RECIPIENTS Comp Mount Type C ORGANIZATION,EXCTEPT DINE 14ECTION VATH MODULES. NORTH ANDOVER, MA 01845 24 St.M.11.04-BUN.g Z U.It 11 THE SALE AND USE OF THE C RESPECIVE (27) TRINA SOLAR #TSM-255PDO5.18 - M,db,wgh,MA 01752 EW RE". DATE EQUIPMENT, W SaARCITY NITH PACE NAME. SHEEt T,(650)63&-1028 F-.(650)638-1029 .I,'r PERMISSION OF SOL C, YETTER: (857) 472-2318 PV 3 2/18/2016 (8M)-SOL-CITY(765-2489) —.1-Ity.— SOLAREDGE #SE50OOA-US00OSNR2 STRUCTURAL VIEWS UPLIFT CALCULATIONS SEE SEPARATE PACKET FOR STRUCTURAL CALCULATIONS. CONFIDENTIAL-THE INFORMATION HEREIN ,NIB NUMBER: P OWER: DESCRIPTION DEEM. CONTAINED SHALL NOT BE USED FOR THE JB-0183485 00 ®\N! AN, HONG AN RESIDENCE Harold Johnson BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNWG SYSTEM }a, NAR HALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 70 THISTLE RD 6.885 KW PV ARRAY -its®fa('C�l�/ PART TO OTHERS OUTSIDE THE RECCONNECTION ORGIT NODULES, NORTH ANDOVER, MA 01845 THE SALE SOLARCITYAN,EXCEPT RR E RESPECTIVE WITH THE RALE AND PSE T,THE UT TH W (27E TRINA SOLAR �(TSM-255PD05.18 zn St.Mind,dDive,Building 2 Unit„ PERMISSION EQUIPMENT,WITHOUT THE WRITTEN PAGE NAVE: SHEEt REV. DAIS Marlborough,NA 50) PERMISSION SOLARCITY INC '"'A""'LR° (/857` 472-2318 T:SOLD)ITY(7648 8(�D)638-1Ity SOLAREDCE SE5000A—US000SNR2 i / UPLIFT CALCULATIONS PV 4 2/78/2016 (BBB)-saL-an(nlszaes) ,.,�..,alaraBxaan, GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND(N)#8 GEC TO TWO(N)GROUND Panel Number: Inv 1: DC Ungrounded INV i-(1)SDLAREDGE#�(SE5000A-USOOOSNR9 LgqBEL: A -(27)TRINA SOLAR gg TSM-255PDO5.18 GEN#168572 ODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:05045593 Tie-In; Supply Side Connection Inverter, 5060W,240V,97.5%;w,TUnifed Disco and ZB,RGM,AFCI PV Module; 255W,232.2W PTC,40MM,Black Frame,H4,ZEP,1000V ELEC 1136 MR Underground Service Entrance INV 2 Voc:38.1 Vpmax: 30.5 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A MAIN SERVICE PANEL E 20OA/2P MAIN CIRCUIT BREAKER Inverter 1 (E)WIRING CUTLER-HAMMER Disconnect CUTLER-HAMMER 1 200A/2P 4 Disconnect 3 SDLAREDGE ac, ' A 30A SE5000A-USOOOSNR2 DC, MP1,MP2:1x16 A B u 0 --------------------- --------- EGc r - ----� B I I e OG I 2 I (E)LOADS cno _ ____ G!m ___ (I V ---------------------- -GEG ---TN MP2,MP3:lxli �~ _J GNa __ Ems_—_ ___________—_----____ —___________- c �-- r-- _________________tJ N i O)Conduit Kit;3/4'EMT _ I 1 I 1 � �-GEC -+ TO 120/240V SINGLE PHASE UTILITY SERVICE i PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Voc#= MAX VOC AT MIN TEMP POI2}}oV d R A (I)CUTLER-HAMMER DG222NRB PV (27)SOLAREDGE 30 11MAZS ( 5(8M 8 Cap per Disconnect;60A,1240V.e,Fuslbie,NEMA 3R AC PowerBox Optimizer,30OW,H4,DC to DC,ZEP DC -(2)ILSCOj IPC 4/0-16 �.I Ineulalion Piercing Connecta:Main 4/0-4,Tap 6-14 B (1)CUTLER-HAMMER/DG221URB nU (i)AHG 16,Solid Bare Copper S Disconnect;30A,24OVac,Non-FueWie,NEMA 3R SUPPLY SIDE CONNECTION.DISCONNECTING MEANS SHALL BE SUITABLE -(1)CUttER-HHAMMER tt NA, -(i)G7ound Rod;5/9'x 8',Copper AS SERVICE EQUIPMENT AND SHALL BE RATED PER NEC. Graundjtreut d Mt;30A,General Duty(DG) I(N)ARRAY GROUND PER 690.47(D).NOTE: PER EXCEPTION N0.2,ADDITIONAL ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF(E)ELECTRODE i �1- 1 AWGls.THWN z.�ok - (1)AWGgo, HWN z.Back — -- -- - rrkn�� { (2)AWG 110 PV YMe,600V,Black V -SOD VDC Isc=15 ADC ®1;1(1)AWG 16,THWN-2,Red O (1)AWG 110 THWN-2,Red 1 I i (1)AWG 86 Solid Bore Copper EGC Vmp =350 VDC t p=11.51 ADC (i)AWC 16,7HTYN 2,write NEUTRAL Vmp =240 VAC Imp=21 AAC I (1)AWG 110.THWN 2,White NEUTRAL Vmp =240 VAC Imp=21 AAC i�-/ (i Cmdut Kit;,3/4'EMT . - -())AXG 15,.SWd Bare,Copper GEC_ _ {t)Conduit K't;_3/4'.FA1T, _ _i ._ .-(1)ANG 18.TH.WN_2,Green..EGC/GEC.-(I)Conduit Kit;,3/47.EMT, _. 1O Ik(2 AWG 110,PV We,60OV,Black Voc*=500 VDC Isc=15ADC (1 )AWG#6' 6 Solid Bare Copper EGC Vmp =350 VDC Imp=7.91 ADC . )Condut Kt;,3/4'EMT....... I I CONFIDENTIAL-THE INFORMATION HEREIN ,p8 NUMBERPREMISE O*a, DESCRIPTION. DESIGN JB-0183485 00 ,SOIafClt�/ CONTAINED SHALL NOT BE USED FOR THE AN, HONG AN RESIDENCE Harold Johnson BENEFIT OF ANYONE EXCEPT SOIARCITY INC., MOUNTING STSTDL -'•..4 NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 70 THISTLE RD 6.885 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION WIN MODULES. NORTH ANDOVER, MA 01845 za St.MaHm odw.Biking 2,Unit u THE SALE AND USE OF THE RESPECTIVE (27) TRINA SOLAR #TSM-255PDO5.18 PAC{NAME: SHEET, REY DA a Mmu,DA.,,MA 01752 SOIARCitt EQUIPMENT,Ni7HWT THE WRITTEN T,(650)638-1628 F.(650)638-1029 PERMISSION OF SOLARO! INC. INVERTER, 857 472-2318 PV 5 2 18 2016 (888)-sOL-CITY(765-2469) w....0ar<ey— SDLAREDGE SESOOOA-USOOOSNR2 THREE LINE DIAGRAM / 1 CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: -Address: 70 Thistle Rd AC DISCONNECT UTILITY SERVICE I , I r I AC DISCONNECT INVERTER AND DC DISCONNECT SOLAR PHOTOVOLTAIC ARRAYS) PHOTOVOLTAIC BACK—FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS AN A/C DISCONNECT PER NEC 690.17 OPERATING VOLTAGE=240V JB-0183485-00 ((��0/� CONFIDENTIAL-THE INFORMATION HEREIN ,qB NUMBEti: JB-0183485 V V PREMISE OWNER: DESCRP)IM. DESIM. \\� CONTAINED SHALL Nor BE USED FOR THE AN, HONG AN RESIDENCE Harold Johnson eS"? (/�� BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MWNTING SYSTEM: S./IarCity NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Camp Mount Type C 70 THISTLE RD 6.885 KW PV ARRAY '►f, PART TOOTHERS,E PT'N THE 1011111 rs MCOULE NORTH ANDOVER, MA 01845 TIE SALE AND EXCEPT INE RESPETial W17H THE SALE AND USE T,THE RESPECTIVE (27) TRINA SOLAR TSM-255PD05.18 24 St.M.rIH 9h MA 017 2 Unit 11 PERMIS HX EQUIPMENT,WLTHWT THE WRITTEN p PAGE NAME, - SKEET: REt. DALE: MarlGorov ,MA 01752 PERMISSION OF SOLARCITY INC. '"`�'�"° /857 472-231 8 T:(650)638-7028 F:(650)638-1029 SOLAREDGE SE5000A—US000SNR2 1 SITE PLAN PLACARD PV 7 2/18/2016 eeB)-sO-c Y(765-2489) a ® a Label Location: — Label Location: Label Location: (C)(CB) (AC)(POI) ME (DC)(INV) Per Code: Per Code: Per Code: NEC 690.31.G.3 Ba ` B NEC 690.17.E NEC690.35(F) Label Location: B =m B TO BE USED WHEN (DC)(INV) - '• INVERTER IS Per Code: UNGROUNDED NEC 690.14.C.2 Label Location: Label Location: (POI)(DC)(INV) ° • ®' Per Code: Per Code: B B® o • NEC 690.17.4;NEC 690.54 • NEC 690.53 -! ! o ! Label Location: •' ° A ® (DC)(INV) Per Code: o ® NEC 690.5(C) -• ! B B o• o ! • Label Location: (POI) • + '! • Per Code: ® ® ! NEC 690.64.B.4 Label Location: t ® (DC)(CB) o ® Per Code: Label Location: B e ! ! NEC 690.17(4) e (D)(POI) • =• . • Per Code: NEC 690.64.8.4 ! ! ^•-B o Label Location: t�® (POI) Per Code: Label Location: ! o ® NEC 690.64.B.7 ® + (AC)(POI) •• • • (AC):AC Disconnect Per Code: °B (C):Conduit NEC 690.14.C.2 (CB):Combiner Box (D):Distribution Panel (DC):DC Disconnect (IC):Interior Run Conduit Label Location: (INV):Inverter With Integrated DC Disconnect (AC)(POI) (LC):Load Center °° Per Code: (M):Utility Meter M•, • NEC 690.54 (POI):Point of Interconnection CONFIDENTIAL–THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR 1 3055 nea�—way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC,NOR SHALL IT BE DISCLOSED z-,�ry'i San Mateo,CA 9-0)6 IN WHOLE IXt IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, Label Set �+� /`� {�/�_ 1:(650)636-3028 1:(650)638-Toz9 EXCEPT IN CONNECTION HATH THE SALE AND USE OF THE RESPECTIVE I�,So��'■_,�,I (asa)-soy-cm(zbs-zvss)www.sdarcay.can SIXARCNY EWIPMENT,WITHOUT THE WRITTEN PERMISSION OF S"CITY INC. V `y a SOIf3ftl'Cy Zep Solar Next-Level PV Mounting Technology Zep Solar Next-Level PV Mounting Technology Zep System Components for composition shingle roofs '�_. .. :. �_,Up-roof Leveling Foot Ground ZeP T terroek ,r n,_.-Rni Part No.850-1172 te,ret+oa PTL fisted to UL457 _: Yep Con patlbte R'HodWe ,l �, ZepGmove - �i __� aaot Attahment �� Comp Mount I Part No.950-1382 Listed to UL 2582 M cdt,ng Block Listed to UL 2703 Hp4T9 Description ' PV mounting solution for composition shingle roofs Iy�; 7 c/(� Works with all Zap Compatible Modules xeaz` Auto bonding UL-listed hardware creates structural and electrical bond • Zep System has a UL 1703 Class"A"Fire Rating when installed using modules from LISTED any manufacturer certified as"Type i"or"Type 2" Interlock Ground Zep V2 DC Wire Clip UL Specifications Pan No.850.1398 Pat No,8541571 Pan No.850.9448 Listed to UL 2703 Listed to UL 497 and UL 2703 Listed to UL 1565 • Designed for pitched roofs • Installs in portrait and landscape orientations • Zep System supports module wind uplift and snow load pressures to 50 par per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards i • Zap System grounding products are UL listed to UL 2703 and UL 467 • Zep System bonding products are UL listed to UL 2703 Engineered for spansup to 72'and cantilevers up to 24" • Zep wire management products listed to UL 1565 for wire positioning devices • Attachment method UL listed to UL 2582 for Wind Driven Rain Array Skirt,Grip,End Caps Pan Nos,850,0113,850-1421, 8541460.850.1467 zepsolar.com zero.da—m Uslod to UL 1565 This document tloes no(oreate any express warzanty by Zep Solar or abaut its Products«servkes.Zep Sc, sole warranty is contained in Lie written product warranty ror This document tloes not create any express warranty by Zep Sola,«abou eprodvck or services.Zep Solar's solo warzan7ls contained in Ne writ"product warranty for each produn.The end-user tlocumentafon skpped..Zep cd—products constitutes Ue sok spedfiealians referred to io the product wananly The custam.1,s solely eacAtproduct.The end-user--son shipped mth Zep Solar.protlucts-W-thesale Ip-1—I—to in the p.—warranty.The--is—1yresponsibtafor venose,the--my cZepSolafsproducls ra'sach usa_Speciflrr—are subject bchange without notice.Patents a rd Apps:zspat5.com. responsible fore symgthe nsodicy or Zepsolars products Mr each use_Speu!Dans aro subject to chafewithout notice.Patents and Apps:xspats.com. Dacumant H e00-1890-001..,A tale last exported:November 13,20152:23 PM --or tre-ta90.1 a-c tate last exported:November 13,20152:23 PM SolarZSolar @ @ SolarEdge Power Optimizer Module Add-On for North America P300 1 P350 f P400 SolarEdge Power Optimizer j I P300 P350 P400 � Module Add-On For North America RrY n °e rY «RPV z , P300(P350 i P400 INPUT .. a nbzol��re s 1 P aal _ .. - +,t m° �e gsn Y I� ax mum DC Input Cu _ ?, e iM1 5 I ht tl fie to&°ry L i i � I OUTPUT DURING OPERATION(POWE R OPTIMIZED CONNECTED TO OPERATING INVERTER) ; rye i OUTPUT DURING STANDBY(POWER OPTIMRER DISCON NECTED FROM INVERTER OR I NVE Flt OFF) STANDARD ARD COMPIiANCE � i Sa«ery 623031 I,Us -_— R°HS INSTALLATION SPECIFICATIONS a It 1 v it s 1 �. I- C. M �{ 41 E.1 I d �� _ .. I ,z D e PVSYSTEMOESIGN USING A SOLAREDGE THREE PHASE THREEPHASE SINGLE PHASE INVERTER 20RV _ 480V Pv power¢ptimization at the module-level m� _ e Upto25Xmore energy a.m° t e«Dpom rent...... 2s ss ' jSUPerier efhaedcy(99i$SE mu 521. ECCP L/S¢ 'u... MdHgatesailtypesofmodulem snatch lasses;I,..maoofactudng ro7erznce to pSbM,.dI, rare el g Rerenrt Orencaticrrs _ yes =Hewbla spsteitid gn for mammy p ce uniaaM1dtj i F t II h th Inglb it Next generaEl renance tivN m,d,l,level-Rol j ModNe level voltage Wtd°wnfor installer and fieefightsrsafety j i f __ .rnvwM1- .a_v rraR_ ave•« _x.ta nnu nvzlent A ww.i.wlaredge uz j, j H- E Temmmount M01)U1,E TSJf�jqkPD06Jp0 Mono Multi Solutions �c 11311 AiA I IT' ­R p—i(ft) 246 260 255 210 0_3 29.9 303 ICA RDA I_(A) 8U20 8,37 8,10 Trin- amount 318 38.0 A&I 382 10. d"'u"i....... I'D 153 15b 159 I� 1. M =iAN— OD! ml,z­—p—(wp) 182 1116 I40 i93 60 CELLI! Maximum Poxer Voltage Vuv(V) 216 28.0 28.1 28.3 MULTICRY$TALLINE MODULE ­4 A;-A opl,cklot vlt,g,jvj-Voc JVj 35.1 352 35,3 36d WITH TRINAMOUNT FRAME lDlrt-cul (A)-I,JR) 207 Ii. 111 121 ci D05.18 245-26OW Solarcells POWER OUTPUT RANGE ill.!cll T­� M9,,,0lflN.1. 1.—(6 mt,­) dropm mounthig,ok,flon ,06—m 1. 160 Nift(A 10) qpModuletlmonsions 1610.192 —N,1 (,S4 11-it—-111 inenesi 70 15.9111 1 Il Glass 3,2 (0,13 imh,,,),Njqh AR Cooled ie GlassMAXIMUM EFFICIENCY 1A —Ife Good aesihefics fos resid—�nfial applicaflons 31,A],AD.dUAd ANNNIDI—AWSY­UMN—Ut G­ 0 Ip 0.,IP 67 mi'd c.WR, PEN—UNG Technology UINI,,4 0 (0,006 fi,lhel), POWER OUTPUT GUARANTEE Fk.R.Im, Type 2 Highly icliubblo due to sffingd autafify coal 3 Ri— itt-1 w 12 2- GSA"­1 M IOP fln9 Cell 4VC(!2-C) Op—ti.-I.—A.1— 40-185`C —p—t—Pt CT it Maumum System IOpOV DC EC)' "r,t—'I T­p,mfc ­ffid­of V.11DR. vmogeivi S TDD,pe,.­Cllffid,,t of So, 0,32%iAC Max Series-A R.tiNg US, �,fifivd kvircm Mi,wiffisfand chodlenging E., Di:-nail.; —p—t—C—filmitit f I'l 0.05%/'C c n Grt dtfio. 10 Y."p—NAI­--hip W—UR 25y.­jN­Power SNSR..ty EP LINEAR PERFORMANCE WARRANTY & Qw- Mldl-fel P,blI:26 pi—I Module,Per 40-ll.flmll 728 Pieces 3i "rS "Ut 6 C U71011 READ SAFETI AND ISTAL'AltON INSTRUCTRANIS BEFSORE USING A- D-t-1 in"mms 1. il 2. 25 solar® ® 19 Single Phase Inverters for North America solar SE3000A-US!SOMA-US/SE5000A-USI SE6000A-USI SE760OA-USI SEt0000A-US/SEI 1400A-US 111.—Ns.SE3800A USI SE5900A US SE6000A-US SE1609A-VS SES9909A US SE11400AU5 OUTPUT olar dge Single Phase Inverters Nnm,-1 AC P-11 0.t,t GGG a G Rc.G 9 G 2G8V _000 7E00 L9a'1G��40V t14G0 VA M—ACP--Output 33G0 4150 5400 a208V OOCO I 8350 8C0920RV: 13GOG VA For North America 5—@2401 50@240V AC—10 v g 11- ^ ✓ SE3000A-US J SE380OA-US/SE500OA-US J SE600OA-USI :R3`G� ✓ AC— t V lage M"_N SE760OA-US/SE10000A-USIfSE1140OA-US .. 2z 264Va° AC FaC entYMn Nom.Max+' 59.3-E0 6. (-11 Hi county 157-c0-h9 SI Hz 4tax.C cuz Outc+_t Cu••ent 12 5 24 ZOBV 48 @ ZQB`J 16 475 A GF9rhh 2' R90V ZS 42 @ 2401 . � .: . _._ ' _. _... - A dopryM nE,izia"a ge non.c"t M orf gnrablx rnrernma, ves vea INPUT _ T _ ,�pVE a 1 m P in f 4USC _ 6750 8— 10259 135GG 15350 W �aR8t1t� 1 "p Vlvg _ Vd - 9 m_CC g __ 325 @ 208V/350 0 240VCv Vdc 'aar �. Max lnR�[LLre ti 95 13 165@2401_ is 23 33@204GV 345 305 Nl—-t 5h,,tCur+— ` P atec ,',..+. E' C '' 6laxrmam overter Ciflc e"cy 972 982 1 083 983 98 1. i. 98 % CEC Wegbted Effice1vy ]5@2081 - 975 °E 911 3 375 325 g75�o 2401=- .. ... ,v $8,@ Z40Y NighHf P rGansum eon r -25 c4 W _ ADDITIONAL FEATURES ftevenu Gadx Ne,ANo Iterfaces RS4850.232 E11.11-1Zga.-e(ap—A) .:. S 0121 ._ Op 'F3 v Rapid Sh tdow9 NEC-4 690,12 Ity ecabled 1 --,!ge dsh,,d—,I,, algia' • STANDARD COMPLIANCE -� a.^ a 4aety _ UL17A i69815419 8 c'4-,T E `- E sslo CC partly cl ss9 _ - ' " INSTALLATION SPECIFICATIONS A t d (W6 ge 31 16 _ ( (83AN QC Fu d /- _., x155511(J1-2 —5/1 184JG m(12 ngs[ nz ngai .. I4 6rao 1 6AWG P sxth Sakty Av ich 25x10 S( n/ ' � (HVWxD} _ 1 75x 315 e260 �_nin ' lNeigFt with aretY Sw.tcb 512123.2} 5471247 'e8 4/461 Ib/kg Coolin8 Natural Comectior aed n nal' Fans(use ap aceab e) The best choice€orSolarEdge enabled systems __ _ plaIeanix)i A 25 <50 dBA IntegSuperior a art (98%ec4on(Type l)for NEC 2011690.11 compliance M".max oPeae�g Temperature 13 m—.1 2s U,+E. 4CU, s Superior efficiency(98%) RaAgP. __ .. P eci g`a Small,lightweight and easy to install on provided bracket ;, ,,.e --- ----- NEMA 3R ---- ---- ----- F Built-in module-level monitoring ® Internet connection through Ethernet or Wireless Outdoor and indoor Installation s.Fixed voltage inverter,DC/AC conversion only ®Pre-assembled Safety Switch for faster installation Optional—revenue grade data,ANSI C12.1 _ US.A CERMANY-iTALti FP.ANCI JAPAN-CHINA-AUSTRALIA-THENETHLRLANUS-ISRAEL tN vvw.solai edge.US