Loading...
HomeMy WebLinkAboutCertificate of Compliance - 796 WINTER STREET 8/21/2001 1 I � im ( TOWN OP NORTH ANDOVER SEWAGE, DISPOSAL S�' S` E,iM I-STALLA-HO`N CERTII=I(:ATION 5 The undersismed here;-,y ceriifv that the S,2,xaLc Disposal System i. located aI ------ was installed in cOntermance with the North Arn-lo-%er Board of He^dth approved plan, Svstem Design Pe^r t —dated � I �. I �0� _. with an approved de--I,�n low of gallons per day The mate a!s,used were in conformance %%--it`t those specified on the approved plan; the system was installed in accordar.ce ,,.ith the provisions of 310 CMR 15.000, Title 5 and local regulations, and the meal Qradip.g agrees substantially with the approved plan. .-ail work is accurate,.v represented ;)r. the ?s-built .which has been submitted to the Board cL ziealth Bed inspection dat-,: - Engineer R Arta,:n:ative Final ;nspect:on cater ►�i♦--- Encn'nee: Rzprese^tat:.e Lnstaller: - m. Date: --- P AS Design Engin �eer: _ _ Date: ---- . o RICHA � C N w ® ' TANGARD C4 A�®,rPCQIS F Vk'jc F` �ONAL ECG\ 1 \ AS-BUILT C IST LOT NUMBER, STREET NAME ASSESSORS MAP & PARCEL NUMBER LOT LINES & LOCATION OF DWELLINGS LOCATIONS & DIMENSIONS OF SYSTEM, INCLUDING RESERVE TIES TO LOT LINES & DWELLING, WELLS a, FROM SEPTIC TANK. b. FROM LEACH AREA LOCATIONS OF DEEP HOLES &PERC TESTS ELEVATIONS OF DISPOSAL SYSTEM TOP OF FDN ELEVATION LOCATIONS OF WELLS, DRAINS, WATERCOURSES WITHIN 1 S0' OF SYSTEM LOCATION OF WATER, GAS, ELECTRIC LINES, CABLE _ DISTANCES FROM CORNERS OF HOUSE TO CENTER OF TANK &D-BOX ORIGINAL STAMP & SIGNATURE IMPERVIOUS AREAS - DRIVEWAYS, ETC. NORTH ARROW LOCATION &ELEVATIONS OF BENCHMARK USED N&M Job number 1.770/ TOWN OF NORTH ANDOVER INSPECTION CHECKLIST FOR SEPTIC SYSTEMS .w Site: � �, f .. � ; ' :: '" Final Date: Installer: Tel: Date Yes No Initials A. Bottom of iced 1. Excavation to proper depth 2. With trenches, sides of excavation are beneath B horizon e _ 3. Edge of excavation specified distance from foundation,etc. ,. Comments: (Use back of sheet for diagrams.) B. Retaining Wall 1. Wall height and width as specified 2. Waterproofed _ 3. Wall minimum 10'to leaching facility 4. Wall meets specifications of plan — Comments: C. Building Sewer 1. Pipe diameter minimum 4" --_-- 2. Schedule 40 pipe 3. Inlet to tank cemented 4. Slope minimum 0.01 or 1/81" er foot minimum 5. Pipe properly act firm base 6. Pipe lad on continues grade m straight ht line gr 7. Cleanouts preced ll change in alignment and grade 8. Manholes at a. 90°change -- 9. 10'minunurn'atlset to water line ......... Comments: - _ D. Septic Tank 1. Level 71-� (,�-�� 2. 1,500 gal minimum 4 3. Gas baffle present on outlet f 4. Manhole to w/in 6"of grade ;,m 5. Manholes over center and each tee 6_ 3-20"mprrlioles 77. Outjeffine cemented 8. ? .0. drop from inlet to.,outet 9 Pipe set Compact base with 6 of/a cru shed stone under " 11 Tank is watertight ., - . 12. fees 12;,rs' 'side of tank --�-„ a.. N &M Job number 1770/ Comments: Date Yes No Initials E. Pump Chamber ✓ d°X 1. If separate from tank,compact base with 6"of/a°stone underneath 2. Minimum 2 pipe to d-box if gravity system 3. 20"access manhole 4. Tank level 5. Watertight 6. Tank size agrees with plan specification 7. Manhole to grade „w- m 8. Check valve and bleeder hole present 9. Alarm in building on separate circuit 10. Alarm fiinctions yo — 11. Manual operating switch — o 0" 12. Pump delivers liquid to d-box Conimen ts: F. Distribution Box 1. D-box level � 2. Minimum 0.17"(2")drop fi•om inlet to outlet. °" " 3. Minimum 6"sump , ,n_ 4. Outlet pipes show equal distribution — 5. Compact base with 6"of stone beneath box 6. Box is watertight 7. All lines cemented with hydraulic cement 8. Schedule 40 pipe 9. First 2' from box laid level Comments: P 0V G. Soil Absorption system � V 1. All stone double-washed 3/n"— 1 '/z" -pea stone Bucket test done? — — _ . 2. Minimum 2"of pea stone above distribution lines — 3. Minimum 6"stone beneath pipe -- 4. Distribution lines capped or connected together ,. 5. Toe of slope stops minimum 5' from edge of property; — ,,_- .. Sa, if not, then Swale. — — Comments: — . �d N&M Job number 1770/ Date Yes No Initials H. Leach Trenches 1. Minimum 2 trenches 2. Length of trenches�a ee with plan. (Max. length 100') 3. net".w Width p esters f>50 feet or specified 'mom° 'u -4 with plan-Minimum 2'; 5. Mm urti" 4. Vent r distance between trenches 10' 6. > "e slope minimum 0.005 or 6"p ,T60' - 7. Depth of trenches below outletwinvert minimum of 6". 8. Pipes set on stabl"b ser- Comments: � -- L Leach Field 1. Maximum length of field 100' ' 2. Pipe slope minimum 0.005 or 6"per 100' 3. Separation between pipes 6'maximum 4. Pipes connected at end&vent end raised 5. Separation between adjacent fields 10'minimum 6. Pipes set on stable base 7. Maximum 4' separation from edge of field to first line 8. Minimum two distribution lines Comments: J. Leaching Pits — — — — 1. Minimum inlet pipe 4" . 2. Pits of concrete .,....,..... ,,,...�.�,,....• 3. d S .. n • � etw�e"•� 12"and 48"wide 11 b ,,, n r e Ce whole on each pit „mm- 5.4. Access cemW.�m....,.. -- 6. cement p hydraulic. - Comments� mente with r �- K. Final Grade 1. Slope over soil absorption system minimum 0.02 2. All system components covered by at least 9"soil 3. Cover soil free of stones larger than 6" ?— -- 4. Grading slopes away from dwelling 5. No areas over system that may pond 6. Grading meets 3:1 slope — ---- 7. Minimum of 9" of fill graded over system s CHECKLIST FOR NORTH ANDOVER SEPTIC SYSTEM PLANS N&M Job 1770/ ��� 2 The following is a checklist that incorporates all Title S and local regulations for septic plans. Name of Applicant: Z:/4 ,q"�i I" Name of Designer; Plan Date: Revision Date: Date of Review: 7 M�. °'°^ r �' � ,_ .. Map: �°�' y Property Address. � � ° � " P' Lot: BOH Reviewer: Type of Plan(new orrupgrade) Number of Bedrooms imAssessor"°5Records: gpd)Garbage Disposal Allowed: General Information: N.A.=North Andover Septic Regulations Other numbers refer to Title 5 OK Problem N/A Street number and map/lot-220(4)(u) � Maximum scale of 1 "=40'for plot plan-220(4) Maximum scale of 1 "=20'for profile and component details-220(4) Legal boundaries of the facility being served.-220(4)(a) Names of abutters from recent tax map- NA 8.02j Number of bedrooms,design calcs.,-NA 8.02i Name&address of record owner&applicant- NA 8.02k Name&address of designer-NA 8.021 Holder and location of all easements-220(4)(b) Date plan drawn&any revision date- NA 8.02m / All dwellings and buildings,existing and proposed-220(4)(c) Location of all existing or proposed impervious areas-220(4)(d) All distances on site plan—NA 8.03a-c Elevation of proposed driveway-NA 8.02t Location and elevation of foundation drain-NA 8.02y Location and dimensions of the system incl.reserve(new const.)-220(4)(e) Limits of excavation of leach area on site plan-NA 8.02z Locus plan-220(4)(t) (Not to scale) North arrow-220(4)(g) Existing and proposed contours-220(4)(g) -- Locations and logs of deep holes-220(4)(h) Locations and logs of percolation tests-220(4)(i) Date(s)of soil testing-220(4)(h)&(i) - Existing grade elevation of each deep hole-220(4)(h) � Elevation of percolation tests—N.A. 8.02n Name of approving authority representative-220(4)(h) &(i) Name of soil evaluator-220(4)0) Soil logs and perc test logs match BOH records Locations of waterlines,drains,and subsurface utilities-220(4)(m) Observed and adjusted g.w.elevation in the vicinity of the system-220(4)(n) Complete profile of the system to scale-220(4)(o),NA 8.02c Cross section of leaching facility-NA 8.02w (Not to scale) Location of benchmark(s)within 50-75 feet of facility-220(4)(q) Note listing all variance requests with proper citations-220(4)(p Local upgrade approval request form submitted-403(1) Original R.S./P.E. stamp, signature&date-220(1)&(2) If P.E.,discipline specified within stamp. MGL C. 112 s. 81M sfc. supplies(w/in 400'),pub.wells(w/in 250'),pvt.wells(w/in 150')-220(4)( Location of watercourses,wetlands,wells,etc.Win 150'of system—NA 8.02r Wetland disclaimer—NA 8.02s RLS plan reference&certification required(prop line setbacks)-220(3) u _ Plan contains designer's certification statement Use approvals/standards checked for I/A system-DEP does., 2 p Perc rate>30 NIPI-not allowed for new,LUA for upgrade-245(1)&(13) Perc rate>60 MPI-must use modified tight tank or IIA technology-245(4) Proposed system qualifies as "shared" system-002(definitions) Flow is over 2,000 gpd-No R.S. allowed-220(1) Design flow was set in accordance with code-203 Existing system location and note on proper abandonment-354 6-"`°` Leaching facility at least 1' above Base Flood elevation-NA 9.05 All p�P g i in Sch 40 minimum-NA 10.01 Basement floor minimum 1' above groundwater elevation-NA 5.04 _ Foundation drain present with elevation-NA 8.02y On-site Soil and Groundwater Review OK Problem N/A Proper deep observation hole logs on plan-220(4)(h) All deep holes and peres shown,including aborted tests-NA 8.02n Soil evaluation forms submitted within 60 days of field work-018(2) Proper percolation test log-220(4)(i) Ample deep observation holes in primary disposal area(minimum 2)- 102(2) Ample deep observation holes in secondary disposal area(minimum 2)- 102(2) Ample perc testing(one in each disposal area,3 in prim.>2,000 gpd)- 104(4) a Deep hole testing conducted within two years-NA 7.05 Hole Identification Numbers: ground elevation el. acceptable soil el. '"„ Leach facilitv invert el. `"" ground water el. " refusal el. bottom of leach facility el. 3" thickness of acceptable soil before&after soil R&R separation to groundwater "° `` + °~ " separation to refusal �. soil class ) °mr perc rate p:7 loading rate y septic tank below g.w. table es or no pump tank below g.w. table ��o �° ('Yes, ) 1 f in filler no of Setback Distances(Given in feet) 15.21 1 YES NO Is the lot in the Lake Cochiewick Watershed? NA 6.00&5.02 OK Problem N/A Septic Tank Leach Facility Property line 10 10 Cellar wall 10 20 2 3 Inground pool 10 20 Slab foundation 10 10 Deck,on footings,etc. 5 10 Waterline 10 10 Private drinking well 75 100 Irrigation well 75 100 Wetlands 75 100 Public well 400 400 Wetlands bordering surface 150 150 water Supply or trio. (in Watershed) Trib.To Surface Water supply 325 325 Reservoirs 400 400 Tributaries to reservoirs 200 200 -- Drains(wat. supply/trio.) 50 100 Drains(intercept g.w.) 25 50 Foundation drains 10 20 Drains(Other) 5 10 Drywells 20 25 - „ Downhill slope 15'to 3:1 slope w/o barrier Building Sewer OK Problem N/A Grease trap required for certain uses(check 230 for details) Pipe diameter listed(4" minimum)-222(l)listed-222(3) Pipe Pipe cast don or 5 h 40 PVC—NA 11.02 Watertight joints specified-222(3)&(4) Pipe laid on compact,fjn- base-222(5) Pipe laid on conti,pu06s grade in straight line-222(7)@ Cleanouts prpe6de all changes in alignment and grade-222(8) Cleanout provided every 100 feet-222(8) Manhole at any 90 degree alignment change-222(8) ,"-Invert elevation at building: Invert elevation at septic tank: Length of run: Slope: (minimum of 0.01 -0.02 desired)-222(6) 10'offset to private well or suction line-222(2) 3 4 Septic Tank OK Problem N/A - Tank is accessible-228(3) No structures above tank–(228(3) Tank can accommodate both primary&reserve–NA 9.04 200%of flow(required&provided given. 1500 min.)-220(4)(f)&223)(1)(a) 2-3" drop from inlet to outlet-227(5) Minimum of 4'liquid depth-223(2) 3"air space above tees/baffles(minimum)-227(4) 9"air space above flow line (minimum)-227(4) Tees are not to be replaced by baffles-227(1) Tees extend 6" above flow line-227(1) Inlet tee extends 10"below flow.line(minimum)-227(6) Outlet tee extends 14" below flow line(more for deeper tanks)-227(6) Gas baffle installed on outlet-227(4) Access manhole cover above center of tank&each tee(except 2 compart)228(2) 3-20"manholes-228(2) 1 childproof,24"riser/manhole w/in 6"of final grade if<1000gpd-228(2) Inlet and outlet tees on center line-227(1) Soil compaction below tank specified(if soil is non-native)-221(2) 6"of<=3/4"stone beneath tank specified-221(2)&22 8(1) If> 1,000 gpd AND not a single fam.dwell. must be 2 tks or 2 comp.-223(1)(b) If plan specifies disposal must be 2 tanks in series or 2 compart. tank-223(1)(c) Buoyancy calcs.required if tank at or below water table-221(8) Tank is watertight-221 (1) 9"of cover over tank(minimum) -228(1) H- 10 loading(min.)-H-20 if traffic-226(3) Top of tank<=36" below grade-221(7) All pumping to tank(if applies)in accordance with-229 Tank is set to keep old system in service during install if possible Distribution Box(Check here if not present: ) OK Problem N/A Inlet elevation: Outlet elevation: 0.17'drop from inlet to outlet(minimum)-232(3)(b) 6"sump(minimum)-232(3)(e) All outlets at same elevation-232(3)(b) ` Outlet pipes laid level for first 2 ft.-232(3)(c) Pipe Sch 40-NA 10.01 r Number of outlets: Number of laterals: Size of outlets: �' – Inlet baffle/tee min. 1" over outlet invert for all d-boxes-232(3)(a), Soil compaction below distribution box specified(if soil is non-native)-221(2) 6"of stone beneath distribution box specified-221(2) —. Box is watertight-221 (1) Top of box<=36"below grade-221(7) Buoyancy calculations required if box is at or below water table-221(8) Pump Chamber(Check here if not present: ) OK Problem N/A Volume specified: 220(4)(r) Pump on elevation- 220(4)(r) - Pump off elevation: 220(4)(x) Alarm on elevation: 220(4)(r) Number of cycles per day-220(4)(r)(also 254(1)(d) if gravity from d-box) Minimum 2" delivery line to d-box if gravity-254(1)(c) 4 5 Pressure dosed 11 if flow>=2,000 gpd-254(1)(a)&254(2)(a) / Cycles per day is consistent with chamber volume-23 1 Volume calculations include flowback volume-2') 1(2) 24 hour storage capacity above pump on elevation-231(2) Number of pumps: 2 if system serves>2 dwelling units-231(6) Capacity of pump(s)- gpm @ 'TDH-220(4)(r) Pump can pass 1 1/4 "solids(minimum)-231(7) Pump controls specified-220(4)(r) Alarm equipment specified-231(2) Alarm is in building and powered on separate circuit from pump-2') 1(9) Pump sequence correct(off-lead on-lag on-alan-n on)-231(8) Pump performance curves included-220(4)(r) Manual operating switch-NA 12.01 Check valve,bleeder hole-NA 12.01 1 childproof,24"riser/manhole to final grade-2'31(5), Soil compaction beneath pump chamber specified(if soil is non-native)-221(2) 6"of<=3/4"stone beneath chmbr.specified-221(2)&228(1), Buoyancy calculations if chamber is at or below water table-221(8)@ 9" of cover over chamber(minimum)-228(1) H- 10 loading(min.)-H-20 if traffic-226(')), Chamber is watertight-221 (1) Top of chamber<=36"below grade-221(7) Leaching Facility(general-complete for all designs) OK Problem N/A 50%larger if garbage disposal-240(4) ��•� Trenches to be used whenever possible-240(6) No vehicle or imperv. area above 11 unless unavoidable-240(7);NA 13.02 Vented if under impervious cover-241 (1) Vented through same pipes as distribution system-241 (1)(a) Vent protected from precipitation/animal entry-241. (1)(b) Vent is placed beyond traffic or impervious area-24 1 (1)(c) All lines connected to vent if bed or trenches-241(l)(d) � 9" cover over peastone-240(9) Reserve area provided(new construction)-248(1) 4" Reserve 4' from primary leach area—NA 9.04 4'(5'if perc rate<=2 MPI) separation to g.w.-212(a) &(b) 4'(down to 2'with variance or I/A-upgrades only)of natural soil under l.f. GW separation is adjusted to highest existing grade if facility cuts into a hillside �'. Pipe slope minimum of 0.005-251(9) Require 5'removal and replacement if in fill-255(5) Top of leach facility<=36"below,grade-221(7) Final grade over l.f.minimum 0.02 ft/ft-240(10) Surface&subsurface drainage away from l.f. -240(1 1)&245(5) -- Minimum design flow 440 gpd without deed restriction—NA 13.01 3:1 slope where grading required-255(2) Toe of fill slope stops 5'from property line or swale installed-255(2) " t Impermeable barrier if<3:1 slope or< 15 feet to—3:lslope-255(2) Impermeable barrier/retaining wall poured concrete—NA 9.02 Retaining wall stamped by P.E.-255(2)(b) Top of retaining wall>=top of peastone elevation-255(2)(f) 10'offset from edge of leach facility to edge of ret. wall'255(2)(g) v Perc test(s)done in most restrictive layer- 104(2) U Perc test 4' below leaching elevation—NA 7.,06 Design flow listed and required/provided leach area given-220(4)(f) Leach pipes SCH40 PVC—NA 10.01 Leach mini es r mum 4'diameter except for dosed system—NA 14.04 p�p minimum Leach lines capped,vented,9�connected together-251(9) r Pressure dosing guidance followed if pressure distribution-254(2)(c), Pressure dosing required over 2,000 gpd or with I/A remedial use-231(1) 5 6 Leachin&'Trenches(Check here if not present: ) OK Problem N/A Number of trenches: Minimum of I trenches-NA 9.01(2) Depth offtenches(max eff.2'): -247(l) Width`of trenches(2'min.,4'max.): -251 (1)(b) Length of trenches(100'max.): -25 1 (1)(a) "Trenches are vented(when>50')-251 (11) Trenches follow contour lines-251(2) Trench spacing 3 times effective width or depth minimum-251 (1)(d) In fill or reserve between trenches, 10'min.-NA 14.0,1&"14.03 Available leach area given(Min.500 s.f.)-NA 9,01 2) Bottom=L x W 'x# = s.f. Sidewall=L x D x# x 2= s.f. Effective leach area given are ,. ° Loadin g factor: Effective area=total a s.f.x LTAR = g/day Effective area is>-design flow of facility being served 2"of 1/8"- 1/2",„2x washed peastone.-247(2) Trench depth,of 3/4" to 1 1/2"double washed stone-247(1) Leach Fields(Check here if not present: ) OK Problem N/A Number of fields: (need dosing chamber if> 1,231 (1)) Length(100'max.); "° '" � -252(2)(b) Width: '°' Total area:L x W = �� � � s. f. Minimum 900 square feet-NA 9.01(1) Distribution lines connected with solid pipe–NA 15.01 Effective leach area given —,t Loading factor: Effective area=total area s.f x LTAR g/dav Effective area is>=design flow of facility being served Minimum of two distribution lines-252(2)(a) 6'line separation(max.)-252(2)(d) 4'maximum separation from edge of field to line-252(2)(e) m R ° 10"minimum separation between adjacent leach fields-252(2)(f) _ Between 6" and 12" of 3/4- 1 1/2"stone beneath field-252(2)(g)&247(2) 2"of 1/8"-1/2"2x washed peastone.-247(2) Final Grading OK Problem N/A Slope over leach area minimum of 0.02 feet/foot–240(10) Grading shall divert drainage away from leach area–240(11) Grading slopes away from dwelling 5/24/01 f:/office/forms/tonackitr.doc 6