HomeMy WebLinkAboutCertificate of Compliance - 72 WINDSOR LANE 3/17/2014 PUBLIC HEALTH DEPARTMENT
Town of North Andover
Community Development Division
C Y7-n
r.-m-TIFICATE OF
uuMPLIANCE
As Of: /17/1
This is to certify that the individual subsurface disposal system received a
SATISFACTORY INSPECTION of the:
Repair of D-Box
By: Robert Amor
At:
Andover,72 Windsor Lane
Map 106D Lot 0070
North MA 01845
The Issuance of this ce)1,,' ate sh 11 not be construed as a guarantee that the system will function satisfactorily.
..ry
Michele Grunt
Public Health Agent
1600 Osgood Street,North Andover,Massachusetts 01845
Phone 978.688.9540 Fax 978.688.8476 Web www.townofnorthandover.com
illllll///���11If�'��� "•
North Andover Health Department
Community Development Division
QNSITE WASTEWATER SY T CONSTRUCTION NO
LOCATION INFORMATION
ADDRESS: 72 Windsor Lane MAP: 106D LOT: 0070
INSTALLER: Robert Amor
DESIGNER:
PLAN DATE:
BOH APPROVAL DATE ON PLAN:
INSPECTIONS
TANK INSPECTION: 3/17/14 (D-Box)
DATE OF BED BOTTOM INSPECTION:
DATE OF FINAL CONSTRUCTION INSPECTION:
DATE OF FINAL GRADE INSPECTION:
SITE CONDITIONS
❑ Contractor reports any changes to design plan
❑ Existing septic tank properly abandoned
❑ Internal plumbing all to one building sewer
❑ Topography not appreciably altered
Comments:
SEPTIC TANK
❑ Building sewer in continuous grade, on
compacted firm base
❑ Cleanouts per plan
❑ Bottom of tank hole has 6" stone base
❑ Weep hole plugged
❑ 1500 gallon tank has been installed
H-10 loading
❑ Monolithic tank construction
❑ Water tightness of tank has been achieved by
visual testing
❑ Inlet tee installed, centered under access port
❑ Outlet tee installed, centered under access pork
(gas baffle/effluent filter)
❑ inch cover to within 6" of finish grade
installed over one access port
❑ Hydraulic cement around inlet & outlet
Comments:
PUNK CHAMBER
❑ Bottom of tank hole has 6" stone base
❑ Weep hole plugged
❑ 1500 gallon Pump Chamber installed
❑ H-10 loading
❑ Monolithic tank construction
❑ Inlet tee installed, centered under access port
❑ Pump(s) installed on stable base
❑ Alarm float working
❑ Pump On/Off floats working
❑ Separate on/off floats
❑ Drain hole in pressure line
❑ cover at final grade installed over pump
access port
❑ Water tightness of tank has been achieved by
testing
❑ Hydraulic cement around inlet & outlet
Comments:
CONTROLPANEL
❑ Alarm & Pump are on separate circuits
❑ Alarm sounds when float is tripped
❑ Location of control panel: basement
❑ Alarm signal located inside: basement
Comments:
DISTRIBUTION-BOX
F
Installed on stable stone base
' H-20 D-Box
Inlet tee (if pumped or >0.08'/foot)
❑ Hydraulic cement around inlet & outlets
1, Observed even distribution
Speed levelers provided (not required)
Comments: