HomeMy WebLinkAboutCorrespondence - 149 MARIAN DRIVE 5/8/2001 MER IMA K ENGINEERING IN Ef VI E , INC.
PROFESSIONAL ENGINEERS • LAND SURVEYORS • PLANNERS
66 PARK STREET 4 ANDOVER,MASSACHUSETTS 01610 TEL(978)475-3555,373-5721 m FAX(978)475-1448^E-MAIL,merreng @aol.com
May 8, 2001
Ms. Sandra Starr
Director of Public Health
Town of North Andover
27 Charles Street
North Andover, MA 01845
RE: 149 Marian Drive
David Amundson
Dear Ms. Starr:
Our office has completed a septic system upgrade plan for the above referenced site.
The site is 163,098 S.F. of which only approximately 20,000 S.F. is upland. The existing
disposal system is located in the rear of the property in close proximity to the wetlands.
This design has been submitted to the Conservation Commission and an Order of
Conditions has been issued for the site (copy enclosed).
Given the existing conditions we have completed a design which maximizes the horizontal
offset from the system to the wetlands and conforms with the provisions of Title 5 and the
North Andover Board of health Regulations to the maximum extent feasible with the
following exceptions:
• Local upgrade approval for distance from S,A.S. to front property line 10' to 5'.
• Distance from S.A.S. to wetland N.A. 5.02 100 ft. to 37 ft.
• Distance from septic tank and pump tank to wetland N.A. 5.02 75 ft. to 50 ft. and
55 ft respectively.
• N.A. 7.05 deep test expiration 2 years. Tests were performed on April 16, 1998.
• N.A. 9.01 (1) min leach field 900 sq. ft. where 851 sq, ft. is proposed.
• N.A. 9.02 retaining wall required is poured concrete where interlocking concrete
blocks with geomembrane is proposed.
We respectfully request that the aforementioned variance and local upgrades be granted as
strict enforcement of the North Andover Regulations would be manifestly unjust and an
equal or greater degree of environmental protection will be achieved by this design given
the existing conditions and the fact that the current system is in failure.
Ms. Sandra Starr
May 8, 2001
Page 2
We appreciate your consideration of these requests.
Very truly yours,
MERRIMACK ENGINEERING SERVICES
William Dufresne
Project Manager
cd
Enclosure
cc: David Amundsen
MERRIMACK ENGINEERING SERVICES, INC. * 66 PARK STREET a ANDOVER, MASSACHUSETTS 01810
SEP'T'IC PLAN SUBMITTAL FORM
LOCATION:�..��G�Li k2 u wJ [A,I Ut�
NEW PLANS: S 25.00/�an ✓
REVISED PLANS: YES $ 60.00/Plan
SITE EVALUATION FORMS INCLUDED; YES NO
DATE: J' l
DESIGN ENGINEER:, _ ✓�i�� Gt/Ixdc.- Aht I li' t nA ( Ci', aoeo,, V
DATE TO CONSULTANT:
*If you want your plans expedited, please submit three plazas and included a
stamped envelope with the correct amount of postage to mail plans to Port
Engineering.
When the submission is all in place, route to the Health Secretary.
MERRIMACK
ENGINEERING E VICES INC.
Engineers ® Surveyors ® Planners
66 Park Street
ANDOVER, MASSACHUSETTS 01810 DATE JOB NO.
(508) 475-3555 ATTENTION �r
Fax (508) 475.1448
TO RE: \
, ft�)I�t�l
ew
WE ARE SENDING YOU ❑ Attached ❑ Under separate cover via the following items:
❑ Shop drawings ❑ Prints ❑ Plans ❑ Samples ❑ Specifications
❑ Copy of letter ❑ Change order ❑
COPIES DATE NO. y� DESCRIPTION
e_ i' ji j" F°fr(�
__0 �
�y r v A LAI&n K-t--1
THESE ARE TRANSMITTED as checked below:
For approval ❑ Approved as submitted ❑ Resubmit copies for approval
❑ For your use ❑ Approved as noted ❑ Submit copies for distribution
❑ As requested ❑ Returned for corrections ❑ Return corrected prints
❑ For review and comment ❑
❑ FORBIDS DUE 19 ❑ PRINTS RETURNED AFTER LOAN TO US
REMARKS 15XP_k9ti
`ter �Y'-I ��,rt"pia. A P Cb C_7c..t L t2 192"C 00 L Q� 7--e
12 ` : � 0 i2u,2
COPY TO
SIGNED:
If enclosures are not as noted,kindly notify us at once.
'Town of North Andover ®��a oT:"a
Office ®f the Health Department °0
Community Development and Services Division
27 Charles Street aAAtao FYpy�4?
North Andover, Massachusetts 01845 "ss"�wU
Sandra Starr Telephone(978)688-9540
Health Director Fax (978)688-9542
June 7,2001 °
Bill Dufresne
Merrimack Engineering
66 Park Street
Andover,MA 01810
Re: 149 Marian Drive
Dear Bill:
This is to inform you that the proposed plans for the site referenced above have been disapproved and have
technical deficiencies as followed:
4levation of perc tests missing. (NA 8.02n)
'Q Stamp and signature not original. (3 10 CMR 15.220(1&2))
" Pipe to septic tank not in straight line. (3 10 CMR 15.222 (7))
•4:°" Cleanouts preceding all changes in alignment of pipe missing. (3 10 CMR 15.222(8))
a„ 51" Three 20"manholes on septic tank not specified. (3 10 CMR 15.228(2))
Bottom elevation of retaining wall not specified. 310 CMR 15.255
g p ( )
7� Local upgrade approval form missing. (The fact that the S.A.S. is proposed within the 50' setback
requires DEP approval,as does the depth of naturally occurring soil in OP#1. There it is 3.T.)
The 2"of peastone is not specified to be double-washed. (3 10 CMR 15.247(2))
If you have any questions,please do not hesitate to call the Board of Health Office.
Sincerely,
ta
Sandra Starr,R.S.,C.H.O. t
Health Director i ; .�..�, �1... vr �b
cc: Amundsen
file Ott ,
��`Al�,�"�-�� W �'l�-� �� �� 1' �.. �"� �9,:I^�.+g.,.��•1°�.� I d�-�.
I30AIZD OI"APPEALS 688-9541 BUILDING 688-9545 CONSERVATION 688-9530 NURSE 688-9543 PLANNING 688-9535
MERRIMA K ENGINEERING SERVICES, INC.
PROFESSIONAL ENGINEERS 0 LAND SURVEYORS 0 PLANNERS
66 PARK STREET A ANDOVER,MASSACHUSETTS 01810 d TEL(978)475-3555,373-5721 •FAX(978)475-1448^E-MAIL:merreng @aol,com
TO: North.Andover Board of Health
FROM: Bill Dufresne/Merrimack Engineering
DATE: e(. ;
TM: 1 0-76°°
TL:
OWNER (NAME & ADDRESS) d „mil
Members of the Board:
An upgrade sewage disposal system plan dated: has been
submitted for the above referenced site. Pursuant to Title 5, and the North Andover
Board of Health Regulations, Local upgrade approval and/or variances are being sought
from the following sections.
w
1...,..
3)
Please consider these requests for approval on your earliest available meeting agenda.
We respectfully request your consideration of these matters.
Very truly yours,
MERRIMACK ENGINEERING SERVICES
William Dufresne
cd
SEPTIC PLAN SUBMITTAL FORM
LOCATION y
NEW PLANS: YES $160.00/Plan
REVISED PLANS: DES $ 60.00/Plan
SITE EVALUATION FORMS INCLUDED: YES 0
SC//
DATE: Z-s---gz Y
DESIGN ENGINEER:
DATE TO CONSULTANT:
When the submission is all in place, route to the Health Secretary.
MERRIMACK ��44CL� OCR `�G°�LQ�1�[v10�4LaL
ENGINEERING SERVICES INC.
Engineers e Surveyors @ Planners
66 Park Street
ANDOVER, MASSACHUSETTS 01510 DATE JOB NO.
(508) 475.3555 ATTENTION
Fax (508) 4751443
TO c � 'm°fir '
WE ARE SENDING YOU ❑ Attached ❑ Under separate cover via the following items:
❑ Shop drawings ❑ Prints ❑ Plans ❑ Samples ❑ Specifications
❑ Copy of letter ❑ Change order ❑
COPIES DATE NO. DESCRIPTION
THESE ARE TRANSMITTED as checked below:
❑ For approval ❑ Approved as submitted ❑ Resubmit copies for approval
or your use ❑ Approved as noted ❑ Submit copies for distribution
❑ As requested ❑ Returned for corrections ❑ Return corrected prints
❑ For review and comment ❑
❑ FORBIDS DUE 19 ❑ PRINTS RETURNED AFTER LOAN TO US
REMARKS
i
ICI Cd w e C A6/ax(_ 1.6-wd ( Y�15-
COPY TO
SIGNED: e
If enclosures are not as noted,kindly notify us at once.
Town ®f North Andover F NOR7p
Office ®f the Health Department F��` �.o .°•;�o0
Community Development and Services Division
27 Charles Street
North Andover, Massachusetts 01845
�9SSgcHUSEtRy
Sandra Starr Telephone(978)688-9540
Health Director Fax(978)688-9542
August 13, 2001
Bill Dufresne
Merrimack Engineering
66 Park Street
Andover, MA 01810
Re: 149 Marian Drive
Dear Bill:
This is to notify you that the revised plans dated 7/26/01 for 149 Marian Drive have been
approved.
The following variances have been granted:
1. Distance from leach area from 10 feet to 5 feet.
2. Minimum leach size from 900 square feet to 851 square feet.
3. Distance to wetlands from 100 feet to 37 feet.
If you have any questions, please do not hesitate to call the Board of Health Office at
978-688-9540.
Sincerely,
Sandra Starr, R.S., C.H.O.
Health Director
S S/smc
cc: Amundsen
File
BOARD OF.APPEALS 688-9541 BUILDING 688-9545 CONSERVATION 688-9530 NURSE 688-9543 PLAINNING 688-9535
Town of North Andover, Massachusetts Form No.a
poRTlq BOARD OF HEALTH Q
O p
' * 6
• DESIGN APPROVAL FOR
SSq�a�SE` SOIL ABSORPTION SEWAGE DISPOSAL SYSTEM
Applicant /2'"� /�.�YYI -UY�.�`" JY _ Test No.
Site Location
Reference Plans and Specs. ���4 ✓�� - �' �q' � °
A ENGINEER DESIGN � DATE
Permission is granted for an individual soil absorption sewage disposal system to be installed
in accordance with regulations of Board of Health.
CHAIRMAN,BOARD OF HEALTH
Fee Site System Permit No. 0