Loading...
HomeMy WebLinkAboutCertificate of Compliance - 149 MARIAN DRIVE 3/12/2003 Town of North Andover � TtpRrh Office of the Health Department Q2-�rctr 4..�6 aOm Community Development and Services Division 27 Charles Street North Andover, Massachusetts 01845 DA4"°�r"°•,s R47 CINUS�; Sandra Starr Telephone(978)688-9540 Public Health Director Fax(978)688. 542 TOWN OF NORTH ANDOVER BOARD OF HEALTH CERTIFICATE OF COMPLIANCE DATE OF COMPLIANCE 3/12/03 This is to certify that the individual subsurface disposal system constructed O or repaired (X) by Todd Bateson at 149 Marion Drive has been installed in accordance with the provisions of Title V of the State Sanitary Code and with the North Andover Board of Health regulations. The Issuance of this certificate shall not be construed as a guarantee that the system will function satisfactorily. r n jAaGrasse Board of Health Inspector BOARD OF APPEALS 688-9541 BUILDING 688-9545 CONSERVATION 688-9530 HEALTH 688-9540 PLANNING 688_9535 TOWN OF NORTH ANDOVER SEWAGE DISPOSAL SYSTEM INSTALLATION CERTIFICATION The u dersigned hereby certify that the Sewage Disposal System ( ) constructed; ( repaired: by _ q__ located at 14,,,�,t was installed in conformance with the North Andover Board of Health approved plan, System Design Permit# , dated with an approved design flow ofallons per day. The materials used were in conformance with those specified on the approved plan; the system was installed in accordance with the provisions of 310 CMR 15.000, Title 5 and local regulations, and the final grading agrees substantially with the approved plan. All work is accurately represented on the As-built which has been submitted to the Board of Health. Bed inspection date: Engineer Representative Final inspection d Engineer Representative Installer: V"462�5t�� Lic.#: Date: l PC- d Design engineer: j Date: . °t" " AS-BUILT CHE CKLIST � LOT" NUMBER, STREET NAME ASSESSORS MAP& PARCEL NUMBER LOT LINES & LOCATION OF DWELLINGS �- LOCATIONS & DIMENSIONS OF SYSTEM, 144. ✓� TIES TO LOT LINES & DWELLING a. FROM SEPTIC TANK. b. FROM LF-ACI4 AREA LOCATIONS OF DEEP HOLES& PERC TESTS ELEVATIONS OF DISPOSAL SYSTEM TOP OF FDN ELEVATION LOCATIONS OF WELLS, DRAINS, WATERCOURSES WITHIN 150' OF SYSTEM LOCATION OF WATER, GAS,ELECTRIC LINES, CABLE DISTANCES FROM CORNERS OF HOUSE TO CENTER OF TANK.&D-ROX ORIGINAL STAMP & SIGNATURE IMPERVIOUS AREAS - DRIVEWAYS, ETC. NORTH ARROW LOCATION &ELEVATIONS OF BENCHMARK USED . ' ) INSPBCTlONCHECKLIST FOR SEPTIC SYSTEMS � Yen NO Initials A. Bottom of Bed ~` Excavation^– – —proper depth | 2. With trenckes,aid�����iono��u�hB6�z� | 3. Edge of excavation specified distance from foundation,etc. Comments: � | B. Retaining Wall l. Wall height and width as specified 2. Waterproofed 3. Wall minimum )0` to|eaobiug facility 4. Wall meets specifications ofplan Comments: � C. Building Sewer � ' ------ 2. Schedule 4Opipe 3. Watertight joints 4. Inlet hmtank cemented ' l Slope minimum O.01 or 10" foot minimum 6. Pipe properly set on compact firm base I Pipe laid oo continuous grade hn straight line & C|aaowutu precede all change io alignment and grade V. Manholes ut any 9U"change 10. |O`minimum offset Ln water lioe Comments: / D. Septic Tank ` 1. Level �~ � l 1,500 gal minimum 3 0ou�uf� �� ouUui --�[�,-- ------ . �pr�u uo 4. Manhole tograde 5. Manholes over center and each tee 6. 3-20`~manholes ------- � 7. InlFt tee minimum l3"under invert --17--- -----' � 8. Outlet tee minimum l4^'under invert ' 9. Outlet line cemented ------' lO. Air space 3"above tees V ------ |1. 2"-3"drop from inlet tooutlet ' 12. Pipe set 13. Compact base with 67`nf1/4"crushed stone under tank 14. Tank/ywatertight Cmnmuonro: � � � / � Yes NO E. Pump Chamber 1. if separate from tank,compact base with 6"of 3/4"stone underneath 2. Minimum 2"pipe to d-box if gravity system 3. 20"access manhole 4. Tank level 5. Watertight 6. Tank size agrees with plan specification 7. Manhole to grade 8. Check valve and bleeder hole present 9. Alarm in building on separate circuit �. 10. Alarm ftinctions 11. Manual operating switch 12. Pump delivers liquid to d-box , Comments: F. Distribution Box 1. D-box level 2. Minimum 0.17"(2")drop from inlet to outlet % 3. Minimum 6"sump , 4. Outlet pipes show equal distribution _ 5. Compact base with 6"of stone beneath box --j'/ 6. Box is watertight 7. All lines cemented with hydraulic cement 8. Schedule 40 pipe Comments: G. Soil Absorption system 1. All stone double-washed-3/4"- 1 %2" -pea stone Bucket test done? 2. Minimum 2"of pea stone above distribution lines 3. Minimum 6"stone beneath pipe _ 4. Distribution lines capped or connected together - 5. Grading meets 3:1 slope 6. Minimum of 9"of fill graded over system 7. Toe of slope stops minimum 5' from edge of property; if not,then swale. Comments: H. Leach Trenches 1. Minimum 2 trenches 2. Length of trenches agree with plan. (Max.length 100') 3. Width of trenches agree with plan-Minimum 2';maximum-4'. 4. Vent present if<50 feet or specified 5. Distance between trenches minimum 4' and maximum of 6' 6. Minimum distance between trenches 10' 7. Pipe slope minimum 0.005 or 6"per 100' 8. Depth of trenches below outlet invert minimum of 6". Yes NO r 9. Pipes set on stable base. Comments: I. Leach Field ' 1. Maximum length of field 100' 2. Pipe slope minimum 0.005 or 6"per 100' 3. Separation between pipe 6 maximum 4. Pipes connected at end ; 5. Separation between adjacent fields 10' minimum -� 6. Pipes set on stable base 7. Maximum 4'separation from edge of field to first line 8. Minimum two distribution lines 9. Maximum perc rate 20 mpi , Comments: I Leaching Pits 1. Minimum inlet pipe 4" 2. Pits of concrete 3. Sidewall between 12"and 48"wide 4. Access manholes on each pit 5. Pipes cemented with hydraulic cement i Comments: K. Final Grade I. Slope over soil absorption system minimum 0.02 2. All system components covered by at least 9"soil 3. Cover soil free of stones larger than 6" 4. Grading slopes away from dwelling 5. No areas over system that may pond