HomeMy WebLinkAboutCorrespondence - 89 MARIAN DRIVE 12/27/2005 { FIUI I jJ � .Y){lh ` c a rt V P 1011k4V9�'�%Ik INNII�� �NI��%WIOk NI�1��kN�lll� December 27, 2005 Anthony Donato, P.E. Merrimack Engineering Services, Inc. 66 Park Street Andover, MA 01810 Re: 89 Marian Drive, Map 107C, Lot 46 Dear Mr. Donato: The proposed septic system design plans for the above site dated November 18, 2004 and received on November 28, 2004 has been reviewed. Unfortunately, it cannot be approved until the following items are corrected. The specific section in Title 5: 310 CMR 15.000, or North Andover regulation that is not met by this design follows each item. 1. Please depict the legal boundaries of the facility. This may be accomplished on a separate sheet if desired. —220 2. Please provide ties or other referenced to fixed objects so the contractor can accurately locate the soil absorption system area—220 3. Please clarify the intended loading of the septic tank to be utilized on this site. The detail indicates it to be H-10 yet provides dimensions associated with an H-20 loading tank, 4. Please utilize trenches as the dispersal method for the soil absorption system or explain why they cannot be used—240 5. Please indicate the bed bottom excavation is to extend 6" into the natural soil—NA 9.02 6. To avoid retaining and possibly mounding the ground waster table, please design the impermeable barrier so it does not intercept the estimated seasonal high ground water table. Please feel free to contact the office with any questions you may have. We look forward to working with you to obtain a septic system that will be in compliance with all regulations and assure protection of public health and the environment of North Andover, Sincerely, S san Y. Sawyer, "ftS/RS'Z Public Health Director cc: Owner File SIG —„ ..y_ o Its pro INC. �t��Lr it [ fir, CC71. �1 G; �a� lj]�c.�LVI�C_, Engineers e Surveyors * Planners 66 Park Street ANDOVER, MASSACHUSETTS 01810 DA-FE JOB No. ( ) 475-3555 AT TEN —_. ----- .I ION Fax (978) 475-1448 TO RE a WE ARE SENDING YOU CI Attached E] Under separate cover via — _ _ .. the followinj items: C1 Shop drawings E__1 Prints 0 flans ❑ Samples I::::1 Specifications [1 Copy of letter E] Change order C_-I ---.... �._.._. COPIES DATE NO, arscrzinTiON THESE AIRE TRANSMITTED as checked below: [.&°' or approval iJ Approved as submitted ❑ Resubmit ---copies for approval [-_1 For your use CI Approved as noted ❑ Submit_. —.....__copies for distribution C] As requested ❑ Returned for corrections ❑ Return_ .corrected prints El For review and comment El ❑ FORBIDS DUE —_ ❑ PRINTS RETURNED AF_I ER LOAN TO US REMARKS l n . , 14 X-0 t/A_h-'7` �1,�^:`.k4�f �A;� �� P„��"��"W�.,� ����",� �lu! �.""0�, „ r �" "` �.., ��}"�-d %�a_� •y,, . �E°,���..�+� "^'m~= .�":�.�'J<';r.„�+'"l � " " COPY TOdd SIGNED: ( % It enclosures are riot as noted,kindly notify us at once. TOWN OF NORTH ANDOVER �hoRrro Office of COMMUNI'TV DEVELOPMENT AND SERVICES HEALTH DEPARTMENT 400 OSGOOD STREET _^°, NORTH ANDOVER, MASSACHUSETTS 01845 9CHUy CHUS & Susan Y. Sawyer, REHS/RS 978.688.9540—Phone Public Health Director 978.688.8476—FAX February 10,2006 Edward Condon 89 Marian Drive North Andover,MA 01845 RE: Septic System Design 89 Marian Drive North Andover,1VIap 1070 Lot 46 Dear Mr.Condon, The North Andover Board of Health has completed the review of the septic system design plan for the above referenced property,submitted on your behalf by Merrimack Engineering Services, Inc. dated,November 18,2005, last revision date January 5,2006. The design has been approved for use in the construction of an upgrade onsite septic system. The 4-bedroom(9- room maximum)design has been approved for use in the construction of a replacement onsite septic system. This approval is valid for two years from the date of the approval in accordance with current local regulations and during this time a licensed septic system installer must obtain a permit and complete this work,and a Certificate of Compliance be endorsed by the installer,designer and the Town of North Andover. This approval is subject to the following conditions: 1. The Health Department was not provided with a plan with an original engineer's stamp and signature. Please note that the office must be provided with a plan with an original stamp and signature and one additional copy of the plan prior to the issuance of an installation permit. 2. If site conditions are found in the field to be different from those indicated on the design plan and/or soil evaluation,the originally issued Disposal System Construction Permit is void,installation shall stop,and the applicant shall reapply for a new Disposal Systems Construction Permit. 3. It is the responsibility of the applicant and/or the applicant's septic system designer,septic system installer or other representative to ensure that all other state and municipal requirements are met. These may include review by the Conservation Commission,Zoning Board,Planning Board,Building Inspector, Plumbing Inspector and/or Electrical Inspector. The issuance of a Disposal System Construction Permit shall not construe or imply compliance with any of the aforementioned requirement 4. The plan does not call for the installation of a septic tank effluent filter but one is recommended. Please be advised that only certain brands of filters are permitted for use in Massachusetts and each is required to follow certain approval criteria. Your designer or installer should work with you to assure a licensed brand is selected for use if you choose to install one. Your effort to provide a properly functioning septic system for your dwelling is greatly appreciated. The Health Department may be reached at 978-688-9540 with any questions you may have. Sincerely Susan Y. Sawyer,REHS/RS Public Health Director Eric]: list of licensed septic system installers Cc: Merrimack Engineering Services, Inc.