We'll have the form to you shortly, but just so you know the issues we found:
Field built correctly.
D-box set level to within 2 1/100ths— nice work, though we did talk about putting in speed levelers in the
event future settling occurs
Y Septic had an effluent filter put in at the outlet end so it requires a manhole cover to grade.
Septic tank was not watertight. Water level was about 6" below the outlet invert. Reilly was going to
figure out what was going on and let us know.