Loading...
HomeMy WebLinkAboutCertificate of Compliance - 45 HOLLOW TREE LANE 9/26/2003 r f:� � �f the H i � i�. f i. ari t o °nuns is 1 1 et ate �rH wr wldt A lo% "GMassa(�iPI"elta 01845 ;bs ���ry^ Heidi �.irriffir°w i'elep how (978)688-95,10 ,4cl`i;z,,Public 11calth 14Ars:sclo Fax (17/8)688-9542 TOWN OF NORTH ANDOVER BOARD OF HEALTH CERTIFICATE OF COMPLIANCE DATE OF COMPLIANCE 9/26/03 This is to certify that the individual subsurface disposal system constructed ( ) or repaired (X) by Todd Bateson at 45 Hollow Tree Lane has been installed in accordance with the provisions of Title V of the State Sanitary Code and with the North Andover Board of Health regulations. The Issuance of this certificate shall not be construed as a guarantee that the system will function satisfactorily. jonatha Markey Chairman,North Andover Board of Health 10181,Y'RN'P°qG6M9545 &`0Y S'E,RVjVHtDN699-°`530 HF,!"IA11689.9540 P1,A.N'IJ'9N6698-9535 TOWN OF NORTH ANDOVER SEWAGE DISPOSAL, SYSTEM INSTALLATION CERTIFICATION The,�indersigned hereby certify that the Sewage Disposal System ( ) constructed; (�repaired: located at Z� -I� � was installed in conformance with the North Andover Board of Health approved plan, System Design Permit# dated with an approved design flow of gallons per day. The materials used were in conformance with those specified on the approved plan; the system was installed in accordance with the provisions of 310 CMR 15.000, Title 5 and local regulations, and the final grading agrees substantially with the approved plan. All work is accurately represented on the As-built which has been submitted to the Board of Health. Bed inspection date: _�� I��?� Engineer Representative Final inspection date: Engineer Repres ntative Installer: Lic.#: Date: Design Engineer: (A­ Date: . '" �,�� , floa-o") � AS-BUILT CHECKLIST LOT NUMBER, STREET NAME ASSESSORS MAP& PARCEL NUMBER LOT LINES & LOCATION OF DWELLINGS LOCATIONS & DIMENSIONS OF SYSTEM TIES TO LOT LINES & DWELLING, WELLS a. FROM SEPTIC TANK b, FROM LEACH AREA LOCATIONS OF DEEP HOLES& PERC TESTS ELEVATIONS OF DISPOSAL SYSTEM TOP OF FDN ELEVATION ✓ LOCATIONS OF WELLS DRAINS WATERCOURSES / WITHIN 150' OF SYSTEM LOCATION OF WATER GAS ELECTRIC LINES CABLE DISTANCES FROM CORNERS OF HOUSE TO CENTER OF TANK&D-BOX = ORIGINAL STAMP & SIGNATURE IMPERVIOUS AREAS - DRIVEWAYS, ETC, NORTH ARROW LOCATION _� &ELEVATIONS OF BENCHMARK USED N&M Job number 1770/ TOWN OF NORTH ANDOVER INSPECTION CHECKLIST FOR SEPTIC SYSTEMS Site: `�� �,a��' � r�. ° � P `r: Final bate: Installer: Tel: Date Yes No Initials A. Bottom of Bed 1. Excavation to proper depth / 2. With trenches,sides of excavation are beneath B horizon t -- 3. Edge of excavation specified distance from foundation,etc. �... Comments: (Use back of sheet for diagrams.) B. Retaining Wall 1. Wall height and width as specified 2. Waterproofed 3. Wall minimum 10'to leaching facility 4. Wall meets specifications of plan Comments: C. Building Sewer 1. Pipe diameter minimum 4" ,.. 2. Schedule 40 pipe 3. Inlet to tank cemented 4. Slope minimum 0.01 or 1/8"per foot minimum 5. Pipe properly set on compact firm base 6. Pipe laid on continuous grade in straight line 7. Cleanouts precede all change in alignment and grade 8. Manholes at any 900 change ... 9. 1.0'minimum offset to water line ,,. Comments: D. Septic Tank I. Level - 2. 1,500 gal minimum 3. Gas baffle present on outlet l , 4. Manhole to w/in 6"of grade 5. Manholes over center and each tee , 6. 3-20"manholes -° 7. Outlet line cemented 8. 2"—3"drop fi•om inlet to outlet 9. Pipe set 10. Compact base with 6"of 1/a"crushed stone under tank i w 11. Tank is watertight 12. Tees 12"off side of tank N&M Job number 1770/ Date Yes No Initials Comments: E. Pump Chamber 1. If separate from tank,compact base with 6"of V stone underneath 2. Minimum 2"pipe to d-box if gravity system 3. 20"access manhole J 4. Tank level / 5. Watertight 6. Tank size agrees with plan specification 7. Manhole to grade 8. Check valve and bleeder hole present 9. Alarm in building on separate circuit 10. Alarm functions 11. Manual operating switch 12. Pump delivers liquid to d-box Comments: F. Distribution Box 1. D-box level 2. Minimum 0.17"(2")drop from inlet to outlet t/ 3. Minimum 6"sump - v - 4. Outlet pipes show equal distribution ✓ 5. Compact base with 6"of stone beneath box t/ 6. Box is watertight 7. All lines cemented with hydraulic cement 8. Schedule 40 pipe 1/ 9. First 2' from box laid level Comments: G. Soil Absorption system 1. All stone double-washed—V—1 %" -pea stone / Bucket test done? 2. Minimum 2"of pea stone above distribution lines 3. Minimum 6"stone beneath pipe 4. Distribution lines capped or connected together 5. Toe of slope stops minimum 5' from edge of property; v 5a, if not,then Swale. Comments: N&M Job number 1770/ Date Yes No Initials H. Leach Trenches 1. Minimum 2 trenches 2. Length of trenches agrees with plan. (Max. length 100') 3. Width of trenches agrees with plan-Minimum 2';maximum-4'. 4. Vent present if>50 feet or specified 5. Minimum distance between trenches 10' 6. Pipe slope minimum 0.005 or 6"per 100' 7. Depth of trenches below outlet invert minimum of 6". 8. Pipes set on stable base. Comments: I. Leach Field 1. Maximum length of field 100' U 2. Pipe slope minimum 0.005 or 6"per 100' Lr 3. Separation between pipes 6'maximum (/ 4. Pipes connected at end&vent end raised 5. Separation between adjacent fields 10'minimum 6. Pipes set on stable base 7. Maximum 4' separation from edge of field to first line 8. Minimum two distribution lines Comments: J. Leaching Pits 1. Minimum inlet pipe 4" 2. Pits of concrete 3. Sidewall between 12"and 48"wide 4. Access manholes on each pit 5. Pipes cemented with hydraulic cement 6. Comments: K. Final Grade 1. Slope over soil absorption system minimum 0.02 2. All system components covered by at least 9"soil T 3. Cover soil free of stones larger than 6" 4. Grading slopes away from dwelling 5. No areas over system that may pond 6. Grading meets 3:1 slope 7. Minimum of 9"of fill graded over system