HomeMy WebLinkAboutPlans - 50 HAY MEADOW ROAD 3/3/2016 SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS TABLE OF CONTENTS LPAGE# DESCRIPTION SOLAR MODULES V 1 0 ® SYSTEM SIZE:11825W DC,10000W AC ® ALL WORK SHALL COMPLY WITH 2014 NEC,2009 IBC,MUNICIPAL CODE,AND SERVICE ENTRANCE PV-1.0 COVER SHEET r-RAIL V 0 • MODULES:(43)REC SOLAR:REC275TP ALL MANUFACTURERS'LISTINGS AND INSTALLATION INSTRUCTIONS. PV-2.0 SITE PLAN ® INVERTER(S): ® PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2014 NEC. PV (1)SOLAREDGE TECHNOLOGIES:SE 1000OA-US(240V) ® ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2014 NEC. MAIN PANEL PV-3.0 LAYOUT • RACKING:SNAPNRACK SERIES 100 UL;FLASHED L FOOT. ® PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY PV 0 PV-4,0 ELECTRICAL SEE PEN D01. GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. ® MODULES CONFORM TO AND ARE LISTED UNDER UL 1701 SUB-PANEL STANDOFFS& PV-5.0 SIGNAGE • SOLAREDGE RAPID SHUTDOWN KIT REQUIRED. ® INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. FOOTINGS si STRUCTURAL DETAIL • STRUCTURAL UPGRADES NEEDED. - RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. - CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(E)AND 2012PV LOAD CENTER CHIMNEY A IFC 605 1.2. F0 - ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. - 9,38 AMPS MODULE SHORT CIRCUIT CURRENT. SM SUNRUN METER ATTIC VENT ® 14.65 AMPS DERATED SHORT CIRCUIT CURRENT(690.8 &690.8(b))_ FLUSH ATTIC VENT FS-1 DEDICATED PV METER PVC PIPE VENT [— INVERTER(S)WITH 5z METAL PIPE VENT INV] INTEGRATED DC DISCONNECT AND AFCI - I< T-VENT FAC EI AC DISCONNECT(S) l[Eill SATELLITE DISH M—C-1 DC DISCONNECT(S) ZFIRE SETBACKS lEEll K _ CB HARDSCAPE COMBINER BOX F_--I INTERIOR EQUIPMENT PL— PROPERTY LINE IE:1 SHOWN AS DASHED SCALE:NTS sunrun A AMPERE AC ALTERNATING CURRENT AFCI ARC FAULT CIRCUIT INTERRUPTER LICENSE NO.750184 AZIM AZIMUTH VICINITYMAP COMP COMPOSITION FOREST STREET­.MARLBOROUGH,NA 01752 DC DIRECTCURRENT PHONE 656576527 (E) EXISTING EXT EXTERIOR 41 CUSTOMER RESIDENCE: JESSICA KIRK FIRM FRAMING $ INT INTERIOR 50 HAY MEADOW RD,NORTH LBW LOAD BEARING WALL ANDOVER,MA,01845 MAG MAGNETIC MSP MAIN SERVICE PANEL TEL,(978)470-2045 APN 104L8-0102 (N) NEW NTS NOT TO SCALE PROJECT NUMBER: OC ON CENTER 221R-050KIRK PRE-FAB PRE-FABRICATED sil PVF POUNDS PER SQUARE FOOT DESIGNER: so Hay Moa�owlld PV PHOTOVOLTAIC AAKASH BAHADUR TL TRANSFORMERLESS DRAFTER: TYP TYPICAL DI Bodoru. V VOLTS 3 T la) W WATTS SHEET REV NAME DATECOMMENTS COVER SHEET A REV:A 12/2/2015 PAGE M PV-1.0 SITE PLAN-SCALE 3164"=VO" / r Tl (N)ARRAY AR-02 (N)ARRAY AR-03 (E)RESIDENCE L--- (E)POOL S'wnrun (N)ARRAY AR-01 LICENSE NO.750184 Cs -FOREST STREET—,-PLEO—GH,—T752 PHONE 88.6576527 MP CUSTOMER RESIDENCE: INV lals SE JESSICA KIRK F-A FAX @Q45284"t@i 50 HAY MEADOW RD,NORTH ANDOVER,MA,01845 TEL.(978)470.2045 APN#:108.8-0102 PROJECT NUMBER: 221R-050KIRK O ev DESIGNER: AAKASH BAHADUR El DRAFTER: DI SHEET SITE PLAN REVA 12/212015 PAGE PV-2.0 ROOF TYPE ATTACHMENT ROOF HEIGHT ROOF FRAME FRAME MAX FRAME OC ROOF EDGE MAX RAIL MAX RAIL DESIGN CRITERIA FRAME TYPE EXPOSURE MATERIAL SIZE SPAN SPACING ZONE SPAN OVERHANG MODULES: AR-01 COMP SHINGLE FLASHED L FOOT. SEE PEN D01. TWO STORY ATTIC WOOD RAFTER (2)2 X 8 22'-2" 16" NO 4'-U. l'-4" REC SOLAR:REC275TP MODULE DIMS: AR-02 COMP SHINGLE FLASHED L FOOT. SEE PEN D01. TWO STORY ATTIC WOOD RAFTER (2)2 X 8 22'-2" 16" NO 4'-0" l'-4" 65.5"x 39"x 1.5" AR-03 COMP SHINGLE FLASHED L FOOT. SEE PEN D01. TWO STORY ATTIC WOOD RAFTER (2)2 X 8 22'-2" 16" NO 4'-0" l'-4" MAX DISTRIBUTED LOAD:3 PSF SNOW LOAD:50 PSF WIND SPEED: 100 MPH 3-SEC GUST. D1-AR-01-SCALE:1t8"=1'-0" D2-AR-02-SCALE:3132"=1'-0" LAG SCREWS: PITCH:40° PITCH:40° 5116"x4.0":2.5"MIN EMBEDMENT AZIM:192° AZIM:282° - T-4" —5'®` 1 PENETRATION SPACING: 5'8" STAGGERED 1' STRUCTURAL UPGRADES PER 6_7-4 ` 13'-2 # -a.$ SHEETS-1. a. -¢.. --',--o -?- �-i -G- -�I 161-51, € TY 16-5"€r ;e 16:_5: a-- - --oma -1W,4'TYP$- ? I : F : I : € —6-7°—a 23: k-6'-5„_ ; 1 e-12'-9" {-9'-10-4 3'-& S-4` z1'-7" sunrun 03-AR-03-SCALE:3132"=V-0" PITCH:40° AZIM:102° LICENSE NO.750184 734FORESTSTREE-W,NARLEORONGN.N,Q1752 PHONE 888657-7 FAX 8055289]91 CUSTOMER RESIDENCE: _ JESSICA KIRK - 5,`g„ 50 HAY MEADOW RD,NORTH s ANDOVER,MA,01845 TEL(978)470-2045 A N 9:104.8-0102 1 19,91, � PROJECT NUMBER: 221R-050KIRK '. .a-o£ --c} X23'.=..a. t a --...£,' 16•_5" DESIGNER: i-"G AAKASH BAHADUR �t ( DRAFTER: � - a DI SHEET 30'_10" —13'-2 —T-8"—¢ LAYOUT REV:A 121212015 PAGE PV-10 1201240 VAC SINGLE PHASE SERVICE METER M NATIONAL GRID UTILITY 13813083 GRID SUPPLY SIDE TAP 5 EXISTING (N)LOCKABLE 200A MAIN BLADE TYPE SOLAREDGE TECHNOLOGIES:SE BREAKER FUSED (N)SUN RUN 10000A-US(240V) FUSED AC DISCONNECT METER 10000 WATT INVERTER COMBINER BOX PV MODULES REC SOLAR:REC275TP 2 OIATMAN ING �4 —4 s —3 —2 -"1 + I,�f (43)MODULES PANEL \�8 �� F-- ('7 OPTIMIZERS WIRED IN(2)SERIES OF(15) FACILITY - r OPTIMIZERS AND(1)SERIES OF(13) LOADS 60A FUSES 2 FUSES JUNCTION BOX OPTIMIZERS SQUARE D 250V METER SOCKET LOAD RATED DC OUTBACK FWPV-12 MIN RATED NEMA3R D222NRB 125A CONTINUOUS& DISCONNECT&AFCI 8-POLE,60OVDC SOLAREDGE POWER OPTIMIZER 3R,60A 240V METER P300 120/240VAC 200A,FORM 2S FUSES ARE NEEDED FOR BOTH POSITIVE AND NEGATIVE DC CONDUCTORS CONDUIT SCHEDULE NOTES TO INSTALLER: # CONDUIT CONDUCTOR NEUTRAL GROUND 1. 15 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE. 2. CONNECT SYSTEM VIA INSULATION PIERCING ON SUPPLY SIDE OF MAIN 1 NONE (2)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER BREAKER IN MAIN PANEL ENCLOSURE.CONDUCTORS ARE FIELD INSTALLED. sunrun 2 314"EMT OR EQUIV. (6)10 AWG THHNtTHWN-2 NONE (1)10 AWG THHNJTHWN-2 3 314"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 NONE (1)8 AWG THHNtTHWN-2 4 314"EMT OR EQUIV. (2)6 AWG THHNITHWN-2 (1)10 AWG THHNITHWN-2 (1)8 AWG THHN/THWN-2 LICENSE NO.750184 5 1 314"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)6 AWG THHNtTHWN-2 (1)8 AWG THHNlTHWN-2 734 FOREST STREET MOO,MRLBOROUCH,­1752 ­NE 868657.6521 FkX e0S 526.9TOt MODULE CHARACTERISTICS OPTIMIZER CHARACTERISTICS CUSTOMER RESIDENCE: JESSICA KIRK REC SOLAR:REC275TP 275 W MIN INPUT VOLTAGE 8 VDC 50 HAY MEADOW RD,NORTH OPEN CIRCUIT VOLTAGE 38.3 V MAX INPUT VOLTAGE 48 VDC ANDOVER,MA,01845 MAX POWER VOLTAGE 31.5 V MAX INPUT ISC 10 ADC TEL(978)470-2045 APNo:1o4.B-0102 SHORT CIRCUIT CURRENT 9.38 A MAX OUTPUT CURRENT 15 RDC PROJECT NUMBER: 221 R-050KI RK SYSTEM CHARACTERISTICS-INVERTER 1 DESIGNER: SYSTEM SIZE 11825 W AAKASH BAHADUR SYSTEM OPEN CIRCUIT VOLTAGE 15V DRAFTER: SYSTEM OPERATING VOLTAGE 350 V DI MAX ALLOWABLE DC VOLTAGE 500 V SHEET ELECTRICAL SYSTEM OPERATING CURRENT 33.8 A SYSTEM SHORT CIRCUIT CURRENT I 45A REV:A 121212015 PER CODE:690.52 PAGE PV-4.0 LABEL LOCATION: =1 (C)(CB) _.— '- PER CODE:NEC690.13.G.3&NEC ---- 690.13.GA LABEL LOCATION' (POI} PER THIS EQUIPMENT FED BY MULTIPLE SOURCE PER CODE:NEC690.13.6 TOTAL RATING OF OVER CURRENT PER CODE:705.12(D}{2} DEVICES,EXCLUDING MAIN SUPPLY =a - OVERCURRENT DEVICE SHALL NOT EXCEED AMPACITY OF BUSBAR � PER CODE:NEC690.56(C) LABEL LOCATION' (UNDER ROOFING MATERIAL) -- PER CODE:NEC690.13.G.1 LABEL LOCATION: e LABEL LOCATION: ELECTRIC SHOCK HAZARD (DC)(INV) LABEL LOCATION: (DC}{INV} PER CODE'NEC690.13.6 $ I(1 ` ON POtlERONE INVERTER THE DC CONDUCTORS OF THIS PER CODE:NEC 690.35(F)TO BE USED PHOTOVOLTAIC SYSTEM ARE WHEN INVERTER IS UNGROUNDED PER CODE:NEC 690.15 AND NEC 690.13(6) UNGROUNDED AND MAY BE ENERGIZED JIM LABEL LOCATION: \�(AC)(POI) \PER CODE:NEC690.13.8 LABEL LOCATION: LABEL LOCATION: TURN OFF PHOTOVOLTAIC (D)(AC)(CB) B (AC){POI} AC DISCONNECT PRIOR TO PER CODE:NEC110.27{C) PER CODE:NEC690.16.B WORKING INSIDE PANEL LABEL LOCATION: LABEL LOCATION: e, 60 g P ) PER COD PER CODE:NEC690.33.E2 PER CODE:NEC690.S-0 ¢- - 240 NISV�\������ ELECTRIC SHOCK HAZARDLABEL LOCATION� \\ LABEL{NDIVIDUOALBREAKERS}CTION DO NOT TOUCH TERMINALS PER}CODE:NEC 690.17.E TERMINALS ON BOTH LINE AND PER CODE:NEC705.12.D.3A LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION sunrun DC VOLTAGE IS ALWAYS PRESENT LABEL LOCATION WHEN SOLAR MODULES ARE `•• ¢ (DC)(INV) T EXPOSED TO SUNLIGHT PER CODE:NEC690.53 i�' LABEL LOCATION:{OG}(INV) LICENSE NO.750184 PER CODE:IFC.60.11.31FC 605.11.1.4 73c FORESTSTREE—W,mnRieoao—,r 1112 NEC 690.15,NEC 690.13(6)&NEC _ P Sae em sszr 690.140.2. _ E INVERTER OUTPUT CONNECTION LABEL LOCATION 3 {POI) CUSTOMER RESIDENCE: DO NOT RELOCATE THIS PER CODE:NEC 705.12.D.2 JESSICA KIRK OVERCURRENT DEVICE 50 HAY MEADOW RD,NORTH ANDOVER,MA,01845 1 TEL(978)470-2045 APN#:104.B-0102 LABEL LOCATION: \ �`�� LEGEND (AC)PER CODE:690.13.8 � �� PROJECT NUMBER: �-� (AC):AC Disconnect 221R-050KIRK ELECTRIC SHOCK HAZARD LABEL LOCATION: (C):Conduit (AC)(POI) DO NOT LINE A PER CODE:NEC 690.17.E DESIGNER: (GB)Combiner Box TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED AAKASH BAHADUR (D)Distribution Panel IN THE OPEN POSITION (DC):DC Disconnect DRAFTER: (IC):Interior Run Conduit DI (INV):Inverter with integrated DC disconnect SHEET (LC):Load Center (M):Utility Meter SIGNAGE (POI):Point of interconnection �REV:A 1272!2015 E PV-5.0 %' ___ 1.Installers to verify rafter size,spacing and sloped spans,and notify the E.O.R of any discrepancies before proceeding. —RIDGE 2.Any rotted or damaged rafters shall be replaced prior to proceeding. 3.As a precaution,old or wet snow should be removed from the roof,if the snow builds up to 18"or more. I [ ' NOTE: 4Ft. ' +, MAX VERAGE = �• _ SYPH 8 HCRI SPACING s. P O _ ? 11114 COLLAR TIES O- ROOF SUPPORTS WHERE APPLIES ' LL 11412 O SLOPE (NO BEARING WALL BELOW) T g �� 4 Qw . P RAIL SEE Q TY ---` = 9 �� INT PRIOR WALLS--- (LOCATION MAY MARY) i 1t l RAFTERITRUSS CHORD SEE PORTRAIT ROOF STRUCTURAL INFO7 OVERALL SPAN ROOF ACCESS SEE ARCH DETAIL 2 ROOF TYPE- COLLAR TIES DETAIL 1 STAGGERED ATTACHMENTS LAYOUT See PV draw ngs fordst--toedgeofroof. 4 STRUCTURAL INFORMATION SRC Job Id: 13361 Ceiling Type: 1t2 gyp.Ed. (E)RIDGE a 1�= AIMI CDS � Collar Tie Space: 32 g Coverage l: 18.15 ` = "-1- _ \g.�0¢ � Frame Size: 3-2x8@16 Ground Snow lost): 56 5 l ox�414-Q" f Sloped Roof Snot Load(ps}: 32 Lag Screw Diameter(in): 5/116 E)RAFTER Lag Screw Embedment(in): 2.5 G Overall Span(f4): 33 FASTEN W1 114"SIMPSON Pty Orientation: Portrait SDS SCREWS X3" (E)STUD WALL ',. Pit Weight(psp: TYPICAL 2-RAIL SYSTEM . (N)A9 SISTERS 3 (BOTH SlPES) O Rafter Sloped Span{ft): 22.17 � 1a� "15�. Rail System: 2RaCC RAIL —STANDOFF - SCREW 32"O,C, '��• 9; Roofing Type: Comp.Shingle PV MODULE RAIL CTWO ROWS) JANOES A.ROOF SHTG Roof Mean Height(f): 26 ROOF SHTG ADAMS r" Roof Slope(degrees): 40 � STRUCTURAL � RAFTERRoof Type:le,49748 Co llarTies Sloped Ceiling?: No�L41�41-417 tiR MAX AVERAGE_ OVERLAP SISTER DETAIL lsT;tk � Standoff Max.Herz.Space(ft): 4 to pPo\NG HQRIZ SPACING t W /(NTS) ' IO;A Standoff Max.Vert.Space(ft): 2.75 4 Ft. Standoff Staggered?: Yes Expir.0613012016 yir)nd Exposure: C DETAIL FLUSHMOUNT Digitally Signed#�y James A.Adam, Wind Speed(mph): 100 Dare'2615.12.03 14:19:23`0800 This sheet not to be used without permission from tgp�� SOLAR-ROOF-CHECK.COM . SUnru43 f 1DESIGNER: SRC Rao�Fv#r,:�¢:eek-. v�c��=nr�=x nnn�s�.. 775 Fde Lane jeSsica kirk Residence STRUCTURAL SHEET: DATE y : 2218 150KIRK all Ha= Meadow Rd San Luis Obis o.04 93409 DRAFTER: SRC Nc 'h Andover,MA 01845 DETAILS S-� 12=u3-2€115