HomeMy WebLinkAboutBuilding Permit # 3/9/2016 Of yAO RTO,eN
BUILDING PERMIT 3? ',a`• °L
TOWN OF NORTH ANDOVER 0 A
p APPLICATION FOR PLAN EXAMINATION o�*
Permit NO:% C Date Received
i 9SSaClWSES
Date Issued: °�±L__1®1
IMPORTANT:Applicant must complete all items on this page
LO28�FaCnUrYt street,
P�ROPEI2I'1'OU1tN>TR George Dema ?npt
Pnnt
MAP f�0' PARCEL ZONING OtSTRtCT Flts�onc Distn� yes rid .
'MaG(�lrte StCo,Villa e`
TYPE OF IMPROVEMENT PROPOSED USE
Residential Non-Residential
0 New Building VOne family
0 Addition 0 Two or more family 0 Industrial
0 Alteration No.of units: 0 Commercial
0 Repair,replacement 0 Assessory Bldg 0 Others:
0 Demolition S/Other:rooftop solar
0 3e$Ic ❑Well C1 Floodplatl []WetFatids C� U1!tersbed Dtstnct
I
Installation of an interconnected rooftop solar PV system:
9.625 KW DC/35 solar panels
Identification Please Type or Print Clearly)
OWNER: Name: George Perna Phone: 978-683-8948
I
Address 280 Farnum St North Andover MA 01845
OOTRACTOR Name PtioTle 978 793 7881
,� S nrcm lnst;3llatmn fin a Inr t�tapMan�1�
4itlf5 j
739 Fdresf$t s�tte40U Madbo*04d Att1752
5upervtsar';x CaJastructlort t�lcense Expr pate
�S i14Ud2� 1f�t17
Moine tt�praa/�nent f,tcen�� � Exp, Bate
� � 18�1 � _ 1ot74f18
ARCHITECT/ENGINEER PZSE.Inc.t Paul K.Zacher Phone: 916-961-3960
Address: 8150 Sierra College Blvd,suite 150,Roseville CA 95661 Reg.No. 50100
FEE SCHEDULE:BULDING PERMIT:$12.00 PER$1000.00 OF THE TOTAL ESTIMATED COST BASED ON$125.00 PER S.F.
Total Project Cost:$ 20.116.25 FEE:$ �
Check No.: 3 13"3 Receipt No.: `
NOTE: Persons contracting with unregistered contractors do not have access to t to guaranty fund
Signature of AgenttOwner ignature of contractor__'
t►ORTIf
Town of
s _
Anctovero
No. 94;ib
h * ver, Mass,
S UBOARD OF HEALTH
PERMIT T ILU Food/Kitchen
Septic System
THIS CERTIFIES THAT -liFoundation BUILDING INSPECTOR
^�� �r�„
has permission to erect...............:..........buildings on. ......}..�., [A ...... .....
t`— Rough
to be occupied as.. .r.(0.....K.%)-....... .�F�e�....�.......�..�...... ........
.......................... chimney
provided that the person accepting this permit shall in every respect conform to thr�terms of the application Final
on file in this office,and to the provisions of the Codes and By-Laws relating to the Inspection,Alteration and
Construction of Buildings in the Town of North Andover. PLUMBING INSPECTOR
Rough
VIOLATION of the Zoning or Building Regulations Voids this Permit.
Final
PERMIT EXPIRES 16 MONTHS ELECTRICAL INSPECTOR
UNLESS CONSTUCTIOSTA Rough
Service
...................... ......................... Final
BUILDING INSPECTOR
GAS INSPECTOR
Occupancy Permit Required to Occupy 6uildin, Rough
Display in a Conspicuous Place on the Premises—Do Not Remove Fina'
No Lathing or Dry Wall To Be Done FIRE DEPARTMENT
Until Inspected and Approved by the Building Inspector. Burner
Street No,
Smoke Det.
OW
March 3,2016
Sunrun Inc.
133 Technology Dr,Suite 100
Irvine,CA 92618
Attn.:To Whom It May Concern
re:Job 2016-02836:George Perna-221 R-28OPERN
The following calculations are for the structural engineering design of the photovoltaic panels
located at 280 Farnum St.,North Andover,MA 01845.After review,PZSE,Inc. certifies that the
roof structure lacks sufficient structural capacity for the applied PV loads.See the following
calculations and Plan Sheets for location and repair to bring the roof structure up to the required
capacity.
If you have any questions on the above,do not hesitate to call
SN OF 'tiSs�
PAUIK.
Prepared By: ZACHER
PZSE,Inc.-Structural Engineers o sTRUCTURAL
No.5Q40Q
Roseville,CA
:Scent ..«;&Ptit _-We!'- o o—`He,{I�� '�._� ° 1_3c6'-,_,60 ., .761 3,965
• a.1.�.�-.-.-.[
1 of 8
Gravity Loading
Roof Snow Load Calculations
ps=Ground Snow Load= 50 psf
C,=Exposure Factor= 0.9 (ASCE7-Table 7-2)
C, Thermal Factor= 1.1 (ASCE7-Table 73)
1=Importance Factor= 1
p,=0.7 C,C,I p, 35 psf (ASCE7-Eq 7-1)
where pg<_20 psf,P,min=Ixps= NIA min snow load
where pg.20 pzf,P,min=20 x I= NIA min snow load t=^r <rs=t
Therefore,pr=Flat Roof Snow Load= 35 psf
P.=C Jh (ASCE7-Eq 7-2)
Cs=Slope Factor= 0.867 ARRAY VARRAY 41 ARRAYS
Cs=Slope Factor= 0.867 ARRAY 21 ARRAY 6
Cs=Slope Factor= 1900 ARRAY 3
Ps=Sloped Roof Snow Load= 30.0 psf ARRAY V ARRAY 41 ARRAYS
Ps=Sloped Roof Snow Load= 30.0 psf ARRAY 2t ARRAY 6
Ps=Sloped Roof Snow Load= 34.7 psf ARRAY 3
PV Dead Load=3 psf(Per Sumun Inc.) -
Roof live load=20 psf
Note:Roof live lead is removed in areas covered by PV anay.
:Roof Dead Load ARRAY i
Composition Shingle 2.00
Roof Plywood 1.50
26 Rafters @ 16`o.c. 1.13
Vaulted Ceiling 0.00 (Ceiling Not Vaulted)
Miscellaneous 090
Total Roof DL ARRAY 1 4.6 Ref
DL Adjusted to 18 Degree Slope 4.9 psf
Roof Dead Load ARRAY 2f ARRAY 6
Composition Shingle 2.00
Roof Plywood 150
2.6 Rafters @ 16°o.c. 1.13
Vaulted Ceiling 0.00 (Ceiling Not Vaulted)
Miscellaneous 0.00
Total Roof DL ARRAY 21 ARRAY 6 4.6 psf
DL Adjusted to 18 Degree Slope 4.9 psf
Roof Dead Load ARRAY 3
Composition Shingle 2.00
Roof Plywood 1.50
Double 2x6 Rafters @ 16"o.c, 2.26
Vaulted Ceiling 0.00 (Ceiling Not Vaulted)
Miscellaneous 0.00
Total Roof DL ARRAY 3 5.8 psf
DL Adjusted to 18 Degree Slope 6.1 psf
Roof Dead Load ARRAY 41 ARRAYS
Composition Shingle 2.00
Roof Plywood 1.50
2x6 Ratters @ 16"o.c. 1.13
Vaulted Ceiling 0.00 (Ceiling Not Vaulted)
Miscellaneous 0.00
Total Roof DL ARRAY 4l ARRAYS 4.6 psf
DL Adjusted to 18 Degree Slope 4.9 psf
2of8
Wind Calculations
Per ASCE 7-05 Components and Cladding
Input Variables
Wind Speed 100 mph
Exposure Category C
Roof Shape Gable/Hip
Roof Slope 18 degrees
Mean Roof Height 26 ft
Building Least Width 25 it
Effective Wind Area 10.9 sf
Design Wind Pressure Calculations
Wind Pressure P=gW(G'Cp)
qh=0.00256'Kz'Kzt'Kd'VA2'I (Eq_6-15)
Kz(Exposure Coefficient)=0.948 (Table 6-3)
Kzt(topographic factor)= 1 (Fig 6-4)
Kd(Wind Directionality Factor)= 0.85 (Table 6-4)
V(Design Wind Speed)=100 mph
Importance Factor=1 (Table6-1)
on= 20.63
Standoff Uplift Calculations
Zone 1 Zone 2 Zone 3 Positive
GCp= 490 -1.69 -2.59 0.50
Uplift Pressure= -18.54 psf -34.96 psf -53.51 psf 1027 psf
Max Rail Span Length= 4.0 ft 4.0 ft 4.0 ft
Longitudinal Length= 2.7 it 27 ft 2.7 it
Attachment Tributary Area= 10.9 sf 10.9 sf 10.9 sf
Footing Uplift= -202 Ib -382 lb -58416
Standoff Uplift Check
Maximum Design Uplift=-584 to
Standoff Uplift Capacity=-CC ii
70016 capacity,584 Ib demand Therefore,OK
Fastener Capacity Check
Fastener='--�1 u'iia Lan
Number of Fasteners=1
Minimum Threaded Embedment Depth=2.5
Pullout Capacity Per Inch=205 lb
Fastener Capacity=820 to
820 lbcapacity>58416 demand Therefore,OK
3of8
Framing Check
ARRAY 9 PASS
w=51 plf
Dead Load 4.9 psf
PV Load 3.0 psi ,
Snow Load 30.0 psf zX 2x6 Rafters @ 16°o.c.
` Member Span=12'-2"
Governing Load Comb. DL+SL Note:Attachments shall be Staggered.
Total Load 37.9 psf
Member Properties
Member Size S(inA3) I(inA4) Lumber Sp/Gr Member Spacing
2x6 7.56 20.80 SPF#2 @ 16"o.c.
Check Bending Stress
Fb(psi)= fb x Cd x Cf x Cr (NDS Table 4.3.1)
875 x 1.15 x 1.3 x 1.15
Allowed Bending Stress=1504.3 psi
Maximum Moment=(wLA2)t 8
=935.782 ft#
=11229.4 in#
Actual Bending Stress=(Maximum Moment)t S
=1484.9 psi
Allowed aActual–18.8%Stressed–Therefore,OK
Check Deflection
Allowed Deflection(Total Load)_ — (E=1400000 psi Per NDS)
=1.216 in
Deflection Criteria Based on = 3imie So=n
Actual Deflection(Total Load) _ (5`w*LA4)t(384-E`I)
=0.630 in
=U232 < U120 Thcr stare OK
Allowed Deflection(Live Load) = UI 80
0.811 in
Actual Deflection(Live Load) _ (5*w*LA4)t(384*E*I)
0.679 in
0216 < 11180 Therefore GK
Check Shear
Member Area=8.3 mA2 Fv(psi)=135 psi (NDS Table 4A)
Allowed Shear=Fv*A =1114 Ib Max Shear(V)=w*L 12= 308 Ib
Alloyed a Actual--27.7"'t.Stressed–Therefore,OK
4of8
Framing Check
ARRAY 21 ARRAY 6 PASS
w=51
Dead Load 4.9 psi
PV Load 3.0 psi -'
Snow Load 30.0 psf 2x6 Rafters @ 16"o.c.
Member Span=6'-5'
Governing Load Comb. DL+SL Note:Attachments shall be Staggered.
Total Load 37.9 pet
Member Properties
Member Size S(inA3) I(inA4) Lumber Sp/Gr Member Spacing
2x6 7.56 20.80 SPF#2 @ 16°o.c.
Check Bending Stress
Fla(psi)= fb x Cd x Cf x Cr (NDS Table 4.3.1)
875 x 1.15 x 13 x 1.15
Allowed Bending Stress=1504.3 psi
Maximum Moment=(wLA2)18
=260.286 it#
=3123.43 in#
Actual Bending Stress=(Maximum Moment)t S
=413.1 psi
;allow=d�Actual-27s`u Stressed--Therefore,CK
Check Deflection
Allowed Deflection(Total Load)= U190 (E=1400000 psi Per NDS)
=0.641 in
Deflection Criteria Based on = ,. P€e z�pa
Actual Deflection(Total Load) _ (5'w*LA4)t(384'E'I)
=0.049 in
=U1572 < U120 Therefore OK
Allowed Deflection(Live Load) _ !iib;
0.427 in
Actual Deflection(Live Load) _ (5*w*LA4)t(384*E*I)
0.053 in
01453 < U180 ?herefore Cali
Check Shear
Member Area= 8.3 in12 Fv(psi)= 135 psi (NDS Table 4A)
Allowed Shear=Fv*A=1114 Ib Max Shear(V)=w*Ll 2= 162 Ib
Allowed,Actual--14.6%Stressed--Therefore.CK
5 of 8
Framing Check
ARRAYS PASS-'T3ith Framing Upgrades
w=58
Dead Load 6.1 psf
PV Load 3.0 psf ,-————————
Snow Load 34.7 psf Double 2x6 Rafters @ 16"o.c.
Member Span=I T-4"
Governing Load Comb. DL+SL Note:Attachments shall be Staggered.
Total Load 43.8 psf
Member Properties-Based on Upgraded Section
Member Size S(inA3) I(inA4) Lumber Sp/Gr Member Spacing
Double 2x6 15.13 41.59 SPF#2 @i6"o.c.
Check Bending Stress
Fb(psi)= fb x Cd x Cf x Cr (NDS Table 4.3.1)
875 x 1.15 x 1.3 x 1.15
Allowed Bending Stress=1504.3 psi
Maximum Moment=(wL12)18
=1296.3 ft#
=15555.6 in#
Actual Bending Stress=(Maximum Moment)/S
=1028.5 psi
Allowed Actual-68.4%Stressed--Therefore.OK
Check Deflection
Allowed Deflection(Total Load)= 1"-$ (E=1400000 psi Per NDS)
=1.333 in
Deflector,Criteria Based on = smpie S'an
Actual Deflection(Total Load) _ (5*w*LA4)t(384*E*I)
=0.474 in
=U338 < U120 Therefore Ch
Allowed Deflection(Live Load) = Ut K
0.888 in
Actual Deflection(Live Load) _ (5*w*LA4)/(384*E*I)
0.565 in
U284 < U180 Therefore OK
Check Shear
Member Area=16.5 in A2 Fv(psi)= 135 psi (NDS Table 4A)
Allowed Shear=Fv*A =2228 He Max Shear(V)=w*L t 2 = 389 Or
Allowed>Ac".uai--17.%Stressed--There-tore,D4
6 of 8
Framing Check
ARRAY 41 ARRAYS PASS
w=51 pit
Dead Load 4.9 psf
PV Load 3.0 psf
Snow Load 30.0 psf 2x6 Rafters @ 16'o.c.
Member Span=8'-2' f
Governing Load Comb, DL-SL Note:Attachments shall be Staggered.
Total Load 37.9 psf
Member Properties
Member Size S(inA3) I(inA4) Lumber Sp/Gr Member Spacing
2x6 7.56 20.80 SPF42 @ 16°o.c.
Check Bending Stress
Fb(psi)= fb x Cd x Cf x Cr (NDS Table 4.3.1)
875 x 1.15 x 1.3 x 1-15
Allowed Bending Stress=1504.3 psi
Maximum Moment=(wLA2)18
=421.62 ft#
=5059.44 in#
Actual Bending Stress=(Maximum Moment)t S
=669.1 psi
AllowedActual–u4.5%Stressed--Thermfore,OK
Check Deflection
Allowed Deflecfion(Told Load)_ _ (E=1400000 psi Per NDS)
=0.816 in
Deflection Criteria Based on = Sopa Sea,
Actual Deflection(Total Load) _ (5WLA4)1(3WE`I)
=0.128 in
=U766 < U120 T beref—Oft
Allowed Deflection(Live Load) = U'i83
0.544 in
Actual Deflection(Live Load) _ (5`w`LA4)t(384`EI)
0.138 in
1-1711 < U180 Therefore DB
Check Shear
Member Area=8.3 in12 Fv(psi)=135 psi (NDS Table 4A)
Allowed Shear=Fv A =1114 Ib Max Shear(V)=w`L 12= 207 Ib
Allowed,Actual--18.6%Stressed--Therefore.CK
7of8
Lateral
2009 IBC CH34
Existing Weight of Effected Building
Level Area Weight(p!Q Weight Ib
Roof 1500 sf 4.9 psi 7350 Ib
Ceiling 1500 sf 6 0 psf 9000 Ib
Vinyl Siding 170 it 2.0 psf 8840 lb (26'Wall Height)
Int Walls 170 it 6 4 psf 28288 Ib
Existing Weight of Effected Building 53478 lb
Proposed Weight of PV System
Weight of PV System(Per Sunrun Inc.) 3.0 psf
Approx.Area of Proposed PV System 621 sf
Approximate Total Weight of PV System 1863 Ib
10%Comparison.
10%of Existing Building Weight(Allowed) 5348 lb
Approximate Weight of PV System(Actual) 1863 lb
Percentlncrease 3.5%
5348lb>1863 lb,Therefore OK
8of8
March 3,2016 aTRU(T RAL ENGIff"M
Sunrun Inc.
133 Technology Dr,Suite 100
Irvine,CA 92618
Subject:Structural Certification for Installation of Solar Panels
Job Number:2016-02836
Client:George Perna-221 R-28OPERN
Address:280 Farnum St.,North Andover,MA 01845
Atfn.:To Whom It May Concern
A field observation of the condition of the existing framing system was performed by an audit team from Sunrun Inc..
From the field observation of the property,the existing roof structures was observed as follows:
The existing roof structure consists of:
•Composition Shingle over Roof Plywood is supported by 2x6 Rafters @ 16"o.c.at ARRAY 1.The rafters are sloped at
approximately 18 degree and have a maximum projected horizontal span of 12 It 2 in between load bearing walls.
•Composition Shingle over Roof Plywood is supported by 2x6 Rafters @ 16"o.c.at ARRAY 21 ARRAY 6.The rafters are
sloped at approximately 18 degree and have a maximum projected horizontal span of 6 ft 5 in between load bearing
walls.
•Composition Shingle over Roof Plywood is supported by 2x6 Rafters @ 16"o.c.at ARRAY 2t ARRAY 6.The rafters are
sloped at approximately 18 degree and have a maximum projected horizontal span of 6 It 5 in between load bearing
walls.
•Composition Shingle over Roof Plywood is supported by 2x6 Rafters @ 16"o.c.at ARRAY 41 ARRAYS.The rafters are
sloped at approximately 18 degree and have a maximum projected horizontal span of 8 It 2 in between load bearing
walls.
Design Criteria:
•Applicable Codes=2009 IBC,ASCE 7-05,and NDS-05
•Ground Snow Load=50 psf
•Roof Dead Load=4.9 psf ARRAY 1 14.9 psf ARRAY 2f ARRAY 6;6.1 psf ARRAY 3
•Basic Wind Speed=100 mph Exposure Category C
•Solar modules=as indicated in attached drawings
As a result of the completed field observation and design checks:
•ARRAY 1 is adequate to support the loading imposed by the installation of solar panels and modules.Therefore,no
structural upgrades are required.
•ARRAY 21 ARRAY 6 is adequate to support the loading imposed by the installation of solar panels and modules.
Therefore,no structural upgrades are required.
•ARRAY 3 is inadequate to support the loading imposed by the installation of solar panel and modules.New 2x6 SPF#2
rafters are required to be sistered to the existing roof rafters to support the additional loading.
•ARRAY 4(ARRAY5 is adequate to support the loading imposed by the installation of solar panels and modules.
Therefore,no structural upgrades are required.
I certify that the capacity of the structural roof framing that directly supports the additional gravity loading due to the solar panel
supports and modules had been reviewed and determined to meet or exceed the requirements in accordance with the 2009 IBC.
If you have any questions on the above,do not hesitate to call. 1N oFM4
Prepared By: PAUL K.
ZACHER
PZSE,Inc.-Structural Engineers STRUCTURAL
Roseville,CA No.50100
m
DocuSign Envelope ID:257A6C3D-5429-483F-AB30-E5F51 D35D68D
22.NOTICE OF RIGHT TO CANCEL
YOU MAY CANCEL THIS TRANSACTION AT ANYTIME PRIOR TO MIDNIGHT OF THE 10TH CALENDAR DAY AFTER YOU SIGN
THIS AGREEMENT AND ANY DEPOSIT PAID WILL BE REFUNDED.SEETHE ATTACHED NOTICE OF CANCELLATION FORM FOR
AN EXPLANATION OF THIS RIGHT.
By initialing below,you expressly acknowledge that you have been advised on your right to cancel this Agreement and have received duplicate copies of
the Notice of Cancellation.
1
Accepted 6p(Initials): _
SUNRUNINC. CUSTOMER
Date: 6/2712015 8aMWAccountNolder
,eocus
--i—by:
Signature"" " Rate;: 5/1/2015 _
1—FacerCD]— D.—i9netl by:
Print Name: Adam Murray Signatures --
esa6acsswo�cnee
eorge erna
Title: Op�ra>_ions Associat=e Accountetnail address*: gdpernaffcotncast.net
'This emall address will be used by Sunrun forolfcial—respondence,such as sending
monthly bills or other invoices.5unrun will never share orsettyour email address to any
SALES CONSULTANT thirdparties.
By signing below acknowledge than am Sunrun accredited,that
(presented this agreement according to-The Right Stuff'and the Account phone number: (978)--683-8948
5unrun Code ofConduc4 and that I obtained the homeowner's
signature on this agreement SecondalpAccmmtNofder o tfonall
Name:william Paulin
f—ft',o«t+.sis�earCpbt Name) Signature:
5ignatttrL�W'WM P"t"'
iiessoso c—AA... Print Name:
Sunrun ID#:5739347031
[10-digit numberyou received from Sunrun]
0510112015 PKI 3VRNKZRAZ-H(Custom PPA Fixed) Page 12 of 18
The Commonwealth of Massachusetts
Department of lndustr ial Accidents
' I Congress Street,Suite 100
Boston,MA 02114-2017
wivw.nrassgavldia
1T�orkers'Compensation Insurance Affidavit:Builders/Contractors/Electricians/Plumbers.
TO BE FILED WITH THE PERMITTING AUTHORITY.
_Applicant Information Please Print Legibly
,dame(BusinessiOrganization/Individual):Sunrun Installation Services,Inc.
Address:775 Fiero Lane,Suite 200
City/State/Zip:San Luis Obispo,CA 93401 Phone#:978-549-9438
Are you an employer:'Chea;th appropriate hoa: Type of project(required):
I.[DI am a employer with 35 emplowes(full andror part-timet* 7, F1 New construction
I m sol proprietor or partnership and have no em lorvees working for me in
�-❑ a a capacity
[ pa p p 8.F1 Remodeling
any capacity.[Na workers'comp,insurance required_]
3.O I am a homeowner doing all work myself[No workers'camp.insurance required.] 9. El Demolition'
4 I am a homeowner and will be hiring contractors to conduct all work on my pmpertp_I will 10❑Building addition
ensure thatall contractors either have workers'compensation insurance or are sole I L❑Electrical repairs or additions
proprietors with no employees.
12.❑Plumbing repairs or additions
5.❑I am a general contractor and I have hired the sub-contraetors listed on the attached sheet_
These sub-contractors have employees and have worker comp.insurance.- 13.�Ronf repairs
6.❑We are a corporation and its officers have exercised their right of exemption per MGL c.
14.F11Other Rooftop Solar
152,§1(4),and we have no employees.[No workers-comp,insurance required.]
'Any applicant that checks box#I must also fill out the section below showing their workers compensation policy information.
t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such.
,Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have
employees.If the sub-contractors have employees,they must provide their workers'camp.policy number.
I atn ati etuplayer that is providitig workers'cotnpetisation itisttrance for my eneptoyees. Below is thepoticy and job site
information.
Insurance Company Name:Zurich American Insurance Company
Policy#or Self-ins.Lic.#:WC013696001&WC013696101 Expiration Date:1010112016
Job Site Address:280 Faroum St,North Andover MA 01845 City/State/Zip:
Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date).
Failure to secure coverage as required under MGL c.152,§25A is a criminal violation punishable by a fine up to$1,500.00
and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a
day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance
coverage verification.
I do hereby certify under the/pains and penalties ofperjury that the information provided above is true and correct.
Signature: := sem G�f .- Date:
Phone#:978-54V9438 l
Official use only. Do not write in this area,to be completed by city or town offcial.
City or Town: Permit/License#
Issuing Authority(circle one):
1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector
6.Other
Contact Person: Phone#:
A ®®® CERTIFICATE OF LIABILITY INSURANCE OATE(MM
1a01rzo15
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER,THIS
CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES
BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED
REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER.
IMPORTANT: if the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to
the terms and conditions of the policy,certain policies may require an endorsement.A statement on this certificate does not confer rights to the
certificate holder in lieu of such endorsement(s).
PRODUCER NTACi
MARSH RISK B INSURANCE SERVICES NAME:
345 CALIFORNIA STREET,SUITE 1300 PHONE
Exf: AIC Na
CALIFORNIA LICENSE NO.0437153 E-MAIL
SAN FRANCISCO,CA 94104 ADDRESS:
INSURER$)AFFORDING COVERAGE NAICp
104960339 STAID-GAX-1516 INSURER A:James River Insurance Company 112203
INSURED INSURER B:NIA NIA
SuaBn Instuteien Services,Inc.
andREG SOiar,Inc. INSURER C,HanSicn Casualty Company 42374
775 Fiero Lane,Suite 200 INSURER 0:
San Luis Obispo,CA 93401 —
INSURER E
INSURER F:
COVERAGES CERTIFICATE NUMBER: SEA-002994222-03 REVISION NUMBER:5
THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD
INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS
CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,
EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS.
IN$R ,ADDL SUSR POLICY EFF POLICY EXP
LTR TYPE OF INSURANCE POLICY NVMBER MMIDDIYYYY MMID.MYY LIMITS
A 1 X COMMERCIALGENERALLIABIUTY WC641241 101711,015 1010112016 1 EACHOCCURRENCE $ 1,000,000
CLAIMS-MADE OOCCUR PREMISES Ea occurte"_ $ 300.00
MED EXP(My one person) $ 10,000
PERSONALS ADVINJURY ; 1,000,000
GEHL AGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE S 2,0DO,OQO
POLICY D j�a 11 LOC PRODUCTS-COMPIOP AGG $ 2,0D0J)7
X 1 OTHER:HostC uor Lietnifty .TOTAL POLICY OMIT S ;O,Wg000
AUTOMOBILE LIABILITY 1 OMBINEm(SINGLE LIMIT i S
ANY AUTO 1 BODILY INJURY(P11 person) $
ALL OWNED SCHEDULED BODILY INJURY(Peraccitlent7 $
AUTOS AVTCS
NON O
HIRED AUTOS AUTOSMED PRO
arEERTYDAMAGE $
C !UMBRELLA LIAB X �GDyy H15XC5023203 10,,0112015 10/0112016 EACH OCCURRENCE $ 10,000,000
XEXCESS U. CLAIMS-MADE AGGREGATE I$ 10,070,000
DEC RETENTION$ g
WORK ERS COMPENSATION STATUTE YtN STATUTE ER
'AN V PROPRIETORIPARTNEWEXECUTNE1E.L.EACH ACCIDENT j$
1 OFFICERNEMBER EXCLUDED'! �NIA '
(Mantlatoryin NH) I E.L.DISEASE-EA EMPLOYE $
�1(ye unser
DES
SCRIPTIOCRIPTION OF OPERATIONS below I E.L.CISEASE-POLICY LIMIT $
1
DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schedule,may be—hed If more space Is required)
Re:Pemdtting within jun dlciion.
CERTIFICATE HOLDER CANCELLATION
Town of Nunn Andover SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE
120 Main SVeeI THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN
Hen,Andover,MA 01845 ACCORDANCE WITH THE POLICY PROVISIONS.
AUTHORIZED REPRESENTATIVE
of Marsh Risk S Insurance Services
Stefan Szuic r —_
©1988-2014 ACORD CORPORATION.All rights reserved.
ACORD 25(2014101) The ACORD name and logo are registered marks of ACORD
DATE
AcoR®® CERTIFICATE OF LIABILITY INSURANCE DATE IMM DD n)
�.�-� 18t2015
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS
CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES
BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED
REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER.
IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must be endorsed. If SUBROGATION IS WAIVED,subject to
the terms and conditions of the policy,certain policies may require an endorsement.A statement on this certificate does not confer rights to the
certificate holder in lieu of such endorsement(s).
PRODUCER CONTACT
Arthur J.Gallagher&Co.Insurance Brokers of CA. v...E FAx
1255 Battery Street#450 .415-546-9300 .415-536-8499
San Francisco CA 94111 EMAIL
INSURERS AFFORDING COVERAGE NAICN
INSURERA:Zurich American Insurance Company 16535
INSURED SUN RINC-01 INSURER B
Sunrun Installation Services Inc. INSURERC:
775 Fiero Lane,Suite 200 INSURER D:
San Luis Obispo,CA 93401
INSURER E:
INSURER F:
COVERAGES CERTIFICATE NUMBER:944362624 REVISION NUMBER:
THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD
INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS
CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,
EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS.
INSRPOLICY EFF POLICY EXP
LTR TYPE OF INSURANCE 'INSD WVD POLICY NUMBER MMIODNYn MMJDDIYYn LIMITS
COMMERCIAL GENERALLIABILITV 11 EACH OCCURRENCE $
CLAIMS-MADE A TOP
ENTED
OCCUR
PREMISES Ea occurz.I. §
MED EXP(Ay one person) $
PERSONAL 6ADVINJURY $
GENL AGGREGATE LIMIT APPLIES PER. GENERALAGGREGATE $
POLICY[::]PRO- ❑
JECT LOC PRODUCTS-GOMPfOP AGG 5
OTHER: 3
AUTOMOBILE LIABILITY §
Ea accitlent)
ANY AUTO BODILY INJURY(Per $
AUTQS ryED kUTQSULEO BODILY INJURY(Peracdtlent) $
HIREDAUTOS NON-OVMED -PROPERTY MAGE $
AUTOS I Per acatlent
§
UMBRELLA LIAB OCCUR EACH OCCURRENCE �$
EXCESS LIAB CLAIMS-MADE AGGREGATE $
DED RETENTION$ $
A WORKERS COMPENSATION y WC013696001 011/2015 1011!2016PER OTIL
A AND EMPLOYERS'LIABILITY YIN WC013696101 01112015 1011/2016 X STATUTE I ER
AN V PROPRIETORYEARTNEWEXECUTIVE E.L.EACH ACCIDENT 57,000,000
OFFICER/MEMBER EXCLUDED'? 'NIA
{Mantlatoryln NNj E.L.DISEASE-EA EMPLOYE $1,000,000
If yes,desaide antler
�DESCRIPTION OF OPERATIONS Celow E.L.DISEASE-POLICY LIMIT I 51,000,000
DESCRIPTION OF OPERATIONS i LOCATIONS I VEHICLES(ACORD 101,Additional Remarks Schetlule,may be attached I(more space Is requimd)
WC013696001-$25,000 Deductible;WC013696101-FL,HI,MA,NJ,NY,OR,VA,WI only.
Evidence of Insurance
CERTIFICATE HOLDER CANCELLATION
SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE
THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN
Town of North Andover ACCORDANCE WITH THE POLICY PROVISIONS.
120 Main St
North Andover MA 01845 USA AUTHORIZED REPRESENTATIVE
az-c
©1988.2014 ACORD CORPORATION.All rights reserved.
ACORD 25(2014101) The ACORD name and logo are registered marks of ACORD
Office of Consumer Affairs and Business Regulation rk,
10 Park Plaza-Suite 5170
Boston,Massachusetts 02116
Home Improvement Contractor Registration
Registration: 180120
Type: Supplement Card
SUNRUN INSTALLATION SERVICES INC. Expiration: 10114/2016
STEPHEN KELLY
775 FIERO LANE SUITE 200
SAN LUIS OBISPO,CA 93401
Update Address and return card.Mark reason for change.
sc„:G axa =n -_1 Address Renewal ID Employment E Lost Card
—Vice afConsumer Affairs&Business Regulafiea License or registration valid for individul use only
�E IMPROVEMENT CONTRACTOR before the expiration date.If found return to:
Office of Consumer Affairs and Business Regulation
istraGon: 980120 Type: 10 Park Plana-Suite 5170
Expiration: 1071412015 Supplement CatJ Boston,MA 02116
SUNRUN INSTALLATION SERVICES INC.
STEPHEN KELLY - -
775 FIERO LANE SUITE 200 - ----—
SAN LUIS OBISPO,CR 93401 U d rsc retary Not valid without si tore
OR
9
4,assx.`...v.0.944 t -.d=c Safety
heard f Su Id-g Rego c data.da d
sera€-CS4M N22
STEPHEN A KELLY
16 PARKWAY ROAD
STONEHAM MA 821
..ar. ;;sioner `0010112`x17`.
SCOPE OF WORK GENERAL NOTES LEGEND AND ABBREVIATIONS ION TABLE OF CONTENTS
rPV3102
DESCRIPTION
-SOLAR MODULES COVER SHEET
SYSTEM SIZE:9625W DC,10000W AC • ALL WORK SHALL COMPLY WLTH 2014 NEG,2009 IBC,MUNICIPAL CODE,AND ALL SE SERVICE ENTRANCE 1 —RAIL
MODULES:(35)REC SOLAR:REC275TP MANUFACTURERS'LISTINGS AND INSTALLATION INSTRUCTIONS. # I SITE PLAN
INVERTER(S): o PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2014 NEC.
(1)SOLAREDGE TECHNOLOGIES:SE 1000OA-US(24OV) o ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2014 NEC. MP MAIN PANEL - LAYOUT
RACKING:SNAPNRACK SERIES 100 UL,FLASHED L FOOT. o PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY -= LAYOUT
SEE PEN D01, GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35- RAFTER
• MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. SP SUB-PANEL ^�STANDOFFS&
FOOTINGS REINFORCMENT
SOLAREDGE RAPID SHUTDOWN REQUIRED o INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741
• RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. PV-4,0 ELECTRICAL
69
STRUCTURAL UPGRADES REQUIRED: o CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 0.31(E)AND 2012 LC PV LOAD CENTER -
RAFTER REINFORCEMENT(ARRAY 3) IFC 605.11.2. CHIMNEY pVS-0 SIGNAGE
e ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT-
0 9.4 AMPS MODULE SHORT CIRCUIT CURRENT. SM SUNRUN METER ,... ATTIC VENT
s 14.08 AMPS DERATED SHORT CIRCUIT CIRCUIT(690.8(a)&890.8(6)).
FLUSH ATTIC VENT
PM DEDICATED PV METER
DESIGN CRITERIA:SNOW LOAD=55 PSF AND WIND=110 MPH. PVC PIPE VENT
• STAGGER PENETRATIONS. INVERTER(S)WITH ZN OFdtp
INV INTEGRATED DC METAL PIPE VENT �V $Y,7
DISCONNECT AND AFCIPAUL
T-VENT K o,
ZACHER
AC AC DISCONNECT(S) STRUCTURAL
SATELLITE DISH No,5010
DC DISCONNECT(S)
FIRE SETBACKS SSIONRLG
fF
QF77i For Structural Only
_ COMBINER BOX HARDSCAPE
F--IINTERIOR EQUIPMENT -PL- PROPERTY LINEaw
L J SHOWN AS DASHED SCALE:NTS iunmn
A AMPERE
AC ALTERNATING CURRENT
AFCI ARC FAULT CIRCUIT INTERRUPTER LICENSE NO.750184
AZIM AZIMUTH
VICINITY MAP COMP COMPOSITION
DC DIRECT CURRENT
(E) EXISTING
EXT EXTERIOR CUSTOMER RESIDENCE:
FIRM FRAMING GEORGE PERNA
INT INTERIOR 280 FARNUM ST,NORTH
LBW LOAD BEARING WALL
ANDOVER,MA,01845
- MAG MAGNETIC
MSR MAIN SERVICE PANEL TEL a€-:e-I ••-ate
(N) NEW PROJECT NUMBER:
NTS NOT TO SCALE 221R-28OPERN
_ OC ON CENTER
QQIPRE-FAB PRE-FABRICATED DESIGNER:
PS POUNDS PER SQUARE FOOT
PV PHOTOVOLTAIC D.ALLEN
TL TRANSFORMERLESS DRAFTER.
TYP TYPICAL DI
,_,,.I V VOLTS
W WATTS SHEET
REV NAME _] DATE COMMENTS COVER SHEET
At REV:Al 31112016
PAGEpV_j_Q
PITCH TRUE MAG PV AREA
SITE PLAN-SCALE=1132"=1'-0" AZIM AZIM (SOFT)
AR-01 18` 68' 54' 337.06
® AR-02 18' 68' 54' 302
AR-03 18' 158' 144' 35.8
AR-04 18' 338' 324' 10644
AR-05 18` 158' 144' 35.8
AR-06 18' 248'1 244'1 70.96
P`
OFA'04
ey PAUL K
ZACHER
STRUCTURAL ,n
No.5010,0�3 p.
/ (N)ARRAY AR-03 S`4'jONALENG�
c
(N)ARRAY AR-04
- `1 (N)ARRAY AR-02sunrun
(N)ARRAY AR-05 /
N l LICENSE NO 750184
(N)ARRAY AR-OS , `-
CUSTOMER RESIDENCE:
GEORGE PERNA
(�POOL 280 FARNUM ST,NORTH
ANDOVER,MA,01845
(E}RESIDENCE T —
1 PROJECT NUMBER:
221 R-280PERN
(N)ARRAY AR-01 DESIGNER:
D.ALLEN
rM C?
DRAFTER:
SE SM INV SHEET
SITE PLAN
REV:A.1 31112016
PAGE PV-2-0
ROOF TYPE ATTACHMENT ROOF HEIGHT ROOF FRAME FRAME TYPE FRAME MAX FRAME OC ROOF EDGE MAX RAIL MAX RAIL DESIG CRITERIA
EXPOSURE MATERIAL SIZE SPAN SPACING ZONE SPAN OVERHANG MODULES:
AR-01 COMPSHINGLE FLASHED L FOOT.SEE PEN DOt TWO ATTICWOOD RAFTERS 2X6 10"-8" 16 NO 4'-0" V-4" REC SOLAR.REC275TP
AR-02 COMP SHINGLE FLASHED L FOOT.SEE PEN D01 TWO ATTIC WOOD RAFTERS 2X6 T-0" 16 NO d•-0" V-4" MODULE DIMS:
65.5"x 39"x 1-5"
AR-03 COMP SHINGLE FLASHED L FOOT.SEE PEN D01 TWO ATTIC WOOD RAFTERS (2}-2X6 14'-3" 16 N6 4'-0" 1-d MAX DISTRIBUTED LOAD:3 PSF
SNOW LOAD:55 PSF
D1-AR-01-SCALE:118"=P-0" WIND SPEED:
PITCH:181 110 MPH 3-SEC GUST
h1,68' LAG SCREWS:
5116"x4•':2.5"MIN EMBEDMENT
PENETRATION SPACING:
0" a-
_�'3"-4"{ 32'-11" 1 "1, STAGGERED
IS-
STRUCTURAL UPGRA
' REQUIRED PER SHEET S
j ] 4,fyP[ a (ARRAY 3)
txof
&tq�
3 7 PAUL K.
t ` ZACHER
STRUCTURAL w
No.50100
T-11, xls -;. .
`SS10NAl�tt�'
D2-AR-02-SCALE:3116"=1'-4" D3-AR-03-SCALE:3116"=1'-6"
PITCH:18' PITCH:18' sunrun
AZIM:68' AZIM:158'
5
� 6 LICENSE NO.750184
3=
T•.
{-4'TYP CUSTOMER RESIDENCE:
J el GEORGE PERNA
280 FARNUM ST,NORTH
}.—.'• I ANDOVER MA 01845
dTYP TEL
3 :O
PROJECT NUMBER:
221 R-280PERN
8'-2"
DESIGNER: -
D.ALLEN
DRAFTER.
DI
SHEET
LAYOUT
REV.A.1 31112016
PAGE PV-3.0
ROOF TYPE ATTACHMENT ROOF HEIGHT ROOF FRAME FRAME TYPE FRAME hfiRX FRAME OC ROOF EDGE MAX RAIL MAX RAIL DESIGN CRITERIA
EXPOSURE MATERIAL SIZE SPAN SPACING ZONE SPAN OVERHANG MODULES:
AR-04 COMP SHINGLE FLASHED L FOOT_SEE PEN DOI TWO ATTIC WOOD RAFTERS 2X6 8'-9" 16 NO 4'-0" 1'-4" REG SOLAR_REC275TP
AR-05 COMP SHINGLE FLASHED L FOOT.SEE PEN D01 TWO ATTIC WOOD RAFTERS 2X6 8'-9" 16 NO 4'-0" 1'_4" MODULE DIMS:
65.9'x 39"x 1.5"
AR-06 COMP SHINGLE FLASHED L FOOT.SEE PEN D01 TWO ATTIC WOOD RAFTERS 2X6 T-0" 16 NO 4-0 V-4" MAX DISTRIBUTED LOAD:3 PSF
SNOW LOAD:55 PSF
D4-AR-04-SCALE:3116"=1'-6" WIND SPEED:
{- 1' }.._F1,_7" 110 MPH 3-SEC GUST.
PITCH:18' 9'_10" 9'AO"
AZIM:338° � LAG SCREWS:
I511 U'x4"2.5"MIN EMBEDMENT
PENETRATION
SPACING:
STAGGERED
i k
S'6•. {-4'TYP�> ? 4TYP t
I
t j
G 0-
2.'9..
FFS'tN OF�4Sy9
PAUL K-
ZACHER
STRUCTURAL
No.50100
SSKHYAL��`
sunrun
D5-AR-05-SCALE:1t4"=1'41" D6-AR-06-SCALE:114"=1'-0"
PITCH-18' PITCH:18' LICENSE NO.750184
AZIM:158' AZIM:248° _1•_4.4[1_ _ __ __ em-««„
! [ CUSTOMER RESIDENCE:
` } 10 GEORGE PERNA
280 FARNUM ST,NORTH
7-1 i. _ 0 [ ___ 3 .___ € ANDOVER MA 01845
[ 4
59 9
6" -4'TYPE E i PROJECT NUMBER:
... ,. 221 R-280PERN
1-0 �- 0 0
DESIGNER:
8" D.ALLEN
DRAFTER.
2'?8"
I DI
SHEET
LAYOUT
REV:AA 31112016
PAGEPV-3.1
DESIGN CRITERIA
MODULES:
i
REG SOLAR:REC275TP
MODULE DIMS:
UP55 RACE Nn 65.5"x39"x15'
I CLT AND AD Wi SISTER AS IN T-Ii E 4-E1,N-AND REFERENCED TOP VIEW. MAX DISTRIBUTED LOAD:3 PSE
R E, h CI -ER E A 448 P M-S.A1PC f DW1 E.s4 D C N--Tfl -E EOu 4 !A - SNOW LOAD:55 PSF
ALONG S Ata AND i2i AT EACH-1 END IF WOOD 5 L:TTING S SEEN OR HEARD,=RE DRILL;'7I H A WIND SPEED:
OR!.LL BIT
- 4 110 MPH 3-SEC GUST
ALT SPT`N FOR FJLL-EN g€EMPEP 0 L-, A-S 'N)s ICE MER-7 ,E}F F't;Si t.,
-Fic C0Mk ON R L-4.T 6'C a NG A{ N- AT EA END, LAG SCREWS:
__ ,STER ALL RPFTEf__N.HE FP-A iT3_MEM EERS INTO WHICH THE ARPAY IS LAGGFfl. \,L€-
5116"x4"2.5"MIN EMBEDMENT
PENETRATION SPACING:
F-1 STAGGERED
STRUCTURAL UPGRADES:
REQUIRED PER SHEET 3-1
x= � U f (ARRAY 3)
iT•
r
.nySN OF�9So
�tSTStth i47 � x+ "4
-. I PAUL K
ZACHER y
_DW'2KC-WOOD SCa_,t s`, G "ING 8 STRUCTURAL y
a > R SER ' NQ 50100
I g �
_N _ _ X6 LAP?ED
=ER$SE O
= P ti'IEy-' `S ALF3�
i [
———. sunrun
F]
LICENSE NO 7501&4
I ------- ------- -
- ----- ------ -I I k !
CEILIMG OI--T
iI ( EhiS.W BEARIN`v WALL i rsx Asa._a�
j I CUSTOMER RESIDENCE:
SIDE VIEW GEORGE PERNA
A Y_`P Rsc El 260 FARNUM ST,NORTH
ANDOVER,MA,01645
I i TEE.-- 3.
PROJECT NUMBER:
——
7--— —— —— 221 R-280PERN
F E
__ 4 DESIGNER:
T_
R - C,kyN D.ALLEN
5JfOPSljm SDW
DRAFTER:
DI
SHEET RAFTER
RAFTER REINFORCEMENT DETAIL REINFORCEMENT
`CALF N-_r. REV:Al 31112016
PAGE PV-3.2
1201240 VAC
SINGLE PHASE SERVICE
OMETER#:
NATIONAL GRID 12 806 105
UTILITY
GRID
—SUPPLY SIDE TAP
t/-4
EXISTING N)LOCKABLE
100A MAIN BLADE TYPE (N)LOCKABLE SOLAREDGE TECHNOLOGIES:SE
BREAKER FUSED BLADE TYPE (N)SUN RUN 10000A-US(240V)
AC DISCONNECT AC DISCONNECT METER 100000 WATT INVERTER PV MODULES
EXISTING t 3 �-3 ,, 3 _ 2 F.-1 REG SOLAR_REC275TP
(35)MODULES
100A MAIN a��a �� `� _ `'I —� T�fr OPTIMIZERS WIRED IN(1)SERIES
FACILITY PANEL - OF(18)OPTIMIZERS AND(1)SERIES
LOADS 60A FUSES JUNCTION BOX OF(17)OPTIMIZERS
-° SQUARE D SQUARED 250V METER SOCKET LOAD RATED DC MIN RATED NEMA3R SOLAREDOE POWER OPTIMIZER
D222NRB DU222RB 125AC0NTIN0OUS& DISCONNECT&AFCI P300
3R,60A 3R,60A,2P 240V METER
1201240VAC 1201240VAG 200A,FORM 2S
CONDUIT SCHEDULE NOTES TO INSTALLER:
1. 18 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE.
# CONDUIT CONDUCTOR NEUTRAL GROUND 2, CONNECT SYSTEM VIA INSULATION PIERCING ON SUPPLY SIDE OF MAIN
1 NONE (4)10 AWG PV WIRE NONE (1)8 AWG BARE COPPER BREAKER IN MAIN PANEL ENCLOSURE.CONDUCTORS ARE FIELD INSTALLED.
sunrun
2 314"EMT OR EQUIV. (4)10 AWG THHNITHWN-2 NONE (1)8 AWG THHNITHWN-2
3 314"EMT OR EQUIV. (2)6 AWG THHNRHWN-2 (1)10 AWG THHNITHWN-2 (1)8 AWG THHNITHWN-2 SOLAREDYSTEM NOTES:
1. SOLAREDGGESE INVERTER AND OPTIMIZERS ARE A LISTED SYSTEM.
4 314"EMT OR EQUIV. (2)6 AWG THHNlTHWN-2 (1)6 AWG THHNITHWN-2 (1)8 AWG THHNfTHWN-2 2,STRING OPERATING VOLTAGE IS CONTROLLED BY INVERTER AND LICENSE NO.750184
MAINTAINED AT 350V DC(NOMINAL) _ __" __-.< 111", _
3.STRING VOLTAGE IS ELECTRONICALLY LIMITED BY INVERTER TO 500V -"-
DC,MAX,
4.STRING CURRENT IS CONTROLLED BY OPTIMIZERS AND IS
MODULE CHARACTERISTICS OPTIMIZER CHARACTERISTICS ELECTRONICALLY LIMITED TO i5A MAX(PER STRING). CUSTOMER RESIDENCE:
5.SOLAREDGE DC SAFETY SWITCH DISCONNECTS BOTH POSITIVE AND GEORGE PERNA
REG SOLAR.REC275TP 275 W MIN INPUT VOLTAGE 8 VDC NEGATIVE DC CONDUCTORS AS REQUIRED BY NEC690.35(A). 280 FARNUM ST,NORTH
ANDOVER,MA,01845
OPEN CIRCUIT VOLTAGE 38.8 V MAX INPUT VOLTAGE 48 VDC
MAX POWER VOLTAGE 31.4 V MAX INPUT ISC 10
ADCC
PROJECT NUMBER:
SHORT CIRCUIT CURRENT 9A MAX OUTPUT CURRENT 15 ADC 221R-280PERN
SYSTEM CHARACTERISTICS-INVERTER i DESIGNER:
D.ALLEN
SYSTEM SIZE 9625 W
DRAFTER:
SYSTEM OPEN CIRCUIT VOLTAGE 18V
DI
SYSTEM OPERATING VOLTAGE 350 V
SHEET
MAX ALLOWABLE DC VOLTAGE 500V ELECTRICAL
SYSTEM OPERATING CURRENT 27.5 A
REV:Al 31112016
SYSTEM SHORT CIRCUIT CURRENT 30A
PER CODE:NEC 69052 PAGE Pv_4 Q
i B N S; LABEL LOCATION: i s el0 e
PER CODE:NEC690.13.&3&NEC LABEL LOCATION:
690A3.G4 JAC)(POI)
PER CODE:NEC69013.B THIS RATING
OVER MULTIPLE SOURCE PER CODE-705.12tD)(2)
TOTAL RATNG OF OVER CURRENT
DEVICES,EXCLUDING MAIN SUPPLY
OVERCURRENT DEVICE SHALL NOT EXCEED
AMPACITY OF BUSSAR
B 6 6 PER CODE:NEC690.56{C)
LABEL LOCATION:
^g'� a= tUNDER ROOFING MATERIAL)
PE1CODE:1IEC690.13.G.1
'Y\ ,N•'(�•7_ LABEL LOCATION:
_ LABEL LOCATION: ELECTRIC SHOCK HAZARD tDC)C V)
{DC){INV) LABEL LOCATION: THE DCCIX+IDUCTORS OF THIS PER CODE:NEC E30.35{F)TO BE USED
_ PER CODE:NEC690.13.B - ON PGWERONE INVERTER PHOTOVOLTAIC SYSTEM ARE WHEN INVERTER IS UNGROUNDED
PER CODE:NEC 690.15 AND NEC 690.13(6) UNGROUNDED AND MAYBEENERG12E0
y
LABEL ICN � .. ..
(AC)(POI) .......-�.. �..... .�..\` 1 V
PER CODE:NEC690.13.6 � LABEL LOCATION:
LABEL LOCATION:
TURN OFF PHOTOVOLTAIC (D)(AC)(CB)
:
- - (AC)(POI) AC DISCONNECT PRIOR TO PER CODENEC11027(C)
PER CODENEC69016.B WORKING INSIDE PANEL
LABEL LOCATION:
LABELLOCATION: A'$ .� '--` `
52.08 {AC}
LAC){POI)
} g PER CODNE033.E ■■J^E\i\'}•
PER CODE:NEC6905d E 690 .2
LABEL LOCATION:
ELECTRIC SHOCK HAZARD
\S��\\\~��\ flewnrun
'\'\
1
LABEL LOCATION: DONOT TOUON TERMINALS CAO}(POB
PER CODE:NEC 69017.E
� (WDNIDUALBR.ERS) TERMINALS ON BOTH LINE AND
PER CODE:NEC705.12D_3.4 LOAD SIDES MAY BE ENERGIZED
IN THE OPEN POSITION
DC VOLTAGE IS ALWAYS PRESENT
LABEL LOCATION WHEN SOLAR MODULES ARE
EXPOSED To SUNLIGHT LICENSE NO.750184
PER CODE.NEC69053 ' A 1:BELLOCATION:
€ a ,
_. (0c)(MV)
- - PER CODE IFC 60113 Ire 605.11 14
NEC 69015,NEC 690_13(B)&NEC
69014C2.
INVERTER OUTPUT CONNECTION LABEL LOCATION: CUSTOMER RESIDENCE:
` P ER)CODE:NEC 705.12.D2 GEORGE PERNA
DO NOT RELOCATE THIS
ovERcuRRErvTDEVICE 280 FARNUM ST,NORTH
ANDOVER,MA.01845
TEL.—
LABEL IOCATiIXtlO v PROJECT NUMBER:
s
_ \� p
- - (AC)PER CODE 690.13.8f'1
221 R-280PERN
LEGEND LABEL L.I.
(AC):AC Disconnect ELECTRIC SHOCK HAZARD (AC)(P01)
DO NOT TOUCH TERMINALS PER CODE.NEC 699.17.E DESIGNER.
(C):Conduit TERMINALS ON BOTH LINE AND
(CB)Combiner Box LOAD SIDES MAY BE ENERGIZED DALLEN
.
(D)Distribution Panel IN THE OPEN POSITION
DRAFTER_
(DC):DC Disconnect DI
(IC):Interior Run Conduit
SHEET
NV):Inverter with integrated DC disconnect
{I
SIGNAGE
(LC):Load Center
(M):Utility Meter REV:A.1 31112016
(POI):Point of interconnection
PAGE PV-5.0