HomeMy WebLinkAboutCertificate of Compliance - 72 SAW MILL ROAD 7/30/2013 PUBLIC HEALTH DEPARTMENT
Town of forth Andover
Community Development Division
CERTIFICATE
COMPLIANCE
As o : 7/30/2013
This is to certify that the individual subsurface disposal system received a
SATISFACTORY INSPECTION of the;
Repair
By: Todd Bateson
At
72 Saw Mill Road
Map 104A Lot 0085
North over
The Issuance this certificate shall not be construed as a guarantee that the system will function satisfactorily.
;Su'��"a wye
Aeath. A nt
1600 Osgood Street,North Andover,Massachusetts 01845
Phone 978.688.9540 Fax 978.688.8476 Web www.townofnorthandover.coni
e '
North Andover Health Department
Community Development Division
QNSITE WASTEWATER Y T CONSTRUCTION NOTES
LOCATION INFORMATION
ADDRESS: 72 Saw Mill MAP: 104A LOT: 0085
INSTALLER: Todd Bateson
DESIGNER:
PLAN DATE:
BOH APPROVAL DATE ON PLAN:
INSPECTIONS
TANK INSPECTION: 7/30/13 D-Box
DATE OF BED BOTTOM INSPECTION:
DATE OF FINAL CONSTRUCTION INSPECTION:
DATE OF FINAL GRADE INSPECTION:
SITE CONDITIONS
❑ Contractor reports any changes to design plan
❑ Existing septic tank properly abandoned
❑ Internal plumbing all to one building sewer
❑ Topography not appreciably altered
Comments:
SEPTIC TANK
❑ Building sewer in continuous grade, on
compacted firm base
❑ Cleanouts per plan
❑ Bottom of tank hole has 6" stone base
❑ Weep hole plugged
❑ 1500 gallon tank has been installed
H-10 loading
❑ Monolithic tank construction
❑ Water tightness of tank has been achieved by
visual testing
❑ Inlet tee installed, centered under access port
❑ Outlet tee installed, centered under access port
(gas baffle/effluent filter)
❑ inch cover to within 6" of finish grade
installed over one access port
❑ Hydraulic cement around inlet & outlet
Comments:
PUMP CHAMBER
❑ Bottom of tank hole has 6" stone base
❑ Weep hole plugged
❑ 1500 gallon Pump Chamber installed
❑ H-10 loading
❑ Monolithic tank construction
❑ Inlet tee installed, centered under access port
❑ Pump(s) installed on stable base
❑ Alarm float working
❑ Pump On/Off floats working
❑ Separate on/off floats
❑ Drain hole in pressure line
❑ cover at final grade installed over pump
access port
❑ Watertightness of tank has been achieved by
testing
❑ Hydraulic cement around inlet & outlet
Comments:
CONTROLPANEL
❑ Alarm & Pump are on separate circuits
❑ Alarm sounds when float is tripped
❑ Location of control panel: basement
❑ Alarm signal located inside: basement
Comments:
DISTRIBUTION-BOX
X Installed on stable stone base
X H-20 D-Box
❑ Inlet tee (if pumped or >0.08'/foot)
X Hydraulic cement around inlet & outlets
❑ Observed even distribution
X Speed levelers provided (not required)
Comments: Called Neil — adjust speed levelers on left side