HomeMy WebLinkAboutCorrespondence - 80 PATTON LANE 1/4/2005 Environmental
JAMES M.KAVANAUGH,P.E. ®Engineering Consultant.
14 Shady Hill Drive * Septic System Designs
North Reading,MA 01864 ® Construction Services
Tel./Fax(978)664-2925 ® Custom Home Builder
January 4, 2005 t
Board of Health
Town of N. Andover
27 Charles Street
N. Andover, MA 01845
Att: Susan Sawyer
Re: Septic System Design
80 Patton Lane
Ms. Sawyer:
Please find enclosed a copy of the buoyancy calculations for the above referenced project.
The calculations demonstrate that no additional flotation provisions are required.
If you have any question please do not hesitate to contact me at(978)664-2925.
Sincerely,
JaAi es
M. Kavanaugh, P.E.
JA N
r 1
-1lTMl ,l
j / is � � �• er— f���; —__.
r
av
�r,
TOWN 01�' �40RTII AN[)0V1P,1t
Oflric(U SERVI(1,S
HEALTH DE3"Al"I"I'MENT
400 0S(R)oi) s'rRi,.F,r
NOR"TH ANDOW-A, MASSAC'H(JSL.'TTS M,84�5
Susan V. Sawyer, RUIVIS/RS 979,004 9540- 1111onc
Foblic Health Dircoor 978,689,9542 FAX',
December 6, 2004
James M. Kavanaugh, P.E.
Environmental Consultant
14 Shady Hill Drive
N. Reading, MA 01864
Re: 80 Patton Lane, Map 106X Lot 0 167
Dear Mr. Kavanaugh:
The proposed septic system design plans for the above site dated October 22, 2004 and received
on November 17, 2004 has been reviewed. Unfortunately, it cannot be approved until the
following items are corrected. Each item is followed by the specific section in Title 5: 310 CMR
15.000, or North Andover regulations which is not met by this design.
Please provide the location and elevation of the foundation drain. If there is no drain,
please make a statement to that effect on the plan. (NA 8.02y)
�-2:" The scale(1"=201)is not stated on the site plan. -220(4)
The soil test data should also state the name of the witness to the soil evaluation:
"Leslie Whelan". -220(4)(h)&(i)
Some of the legal boundaries of the property are missing from the plan, -220(4)(a)
�,/5. The site plan is missing the distances from the septic tank to the property line and
from the soil absorption system to the dwelling. -8.02z
6. , A note is required stating the building sewer shall be laid on a compact, firm base, and
on a continuous grade, in a straight line. (3 10 CMR 15.222(5)&(7))
Please sp,6 cify that if the existing tank is to remain, it must be inspected by a Title 5
inspector and certification provided to the Board of Health that the tank meets the
following criteria:
a. the tank is watertight
/b. 2-3" drop from inlet to outlet, (310 CMR 15.227(5))
c. minimum of 4'liquid depth. (3 10 CMR 15,223(2))
d. there is 9" minimum and 36" maximum of cover material over the tank(3 10 CMR
15.221(7) and 228(1))
e. the tank has a loading of H-10 (3 10 CMR 15.226(3))
"5. Additionally, if the existing tank is to remain, please specify that the tees and manhole
risers are to comply with Title 5:
a.) The inlet tee to the septic tank must extend 10" minimum below the flow line and
the outlet tee must extend 14" below the flow line. (3 10 CMR 15.227(6))
ro b.) Tees must extend 6" above the flow line. (3 10 CMR 15.227(l))
c.) Tees must have 3" air space above them. (3 10 CMR 15227(4))
d-) One manhole must be brought to within 6" of final grade. If the cover is located
at grade, it must be secured to prevent unauthorized access. (3 10 CMR
15.228(2))
e.) The inlet and outlet tees must be located directly under the manholes. (3 10 CMR
15.227(l))
If a the septic tank is to be replaced, the plan should provide:
a.)buoyancy calculations for the septic tank. Regarding Note 13, if a pad is needed,
please provide specs. -221(8)
b. a minimum liquid depth of 4 . -223(2)
c. a description of the proper method to abandon the existing septic tank(or
reference to the section of the code). -354
7. Regarding the effluent filter, Note#11 should provide a filter maintenance schedule.
Also, the filter type/name should be noted on the manhole cover.
U/S. A notation is needed regarding the d-box outlets. The elevations must all be the same,
and the pipes must be level for 2' after the d-box. -232(3)(b) & (c)
9. A notation is needed regarding the d-box being watertight. Note number 10 should
include d-box. -221(1)
10. Please specify the proper size (< 1-1/2") for stone that is to be used beneath the
distribution box. —221(2)
11. Before construction begins on the system, a minimum of one deep hole in the vicinity
of the leaching field will be required to determine that the soils are consistent with
those found in the design. If soil is determined to be less pervious than the design,
construction will be halted and a new design will have to be submitted, --- 102(2)
11 A written request to be on the agenda of the Board of Health meeting for the local
variances must be submitted. The reduction to ground water must be explained in
detail. If approved a draft 4-bedroom deed restriction must be submitted prior to
approval.
Please feel free to contact the office with any questions you may have. We look forward to
working with you to obtain a septic system which will be in compliance with all regulations and
assure protection of public health and the environment of North Andover.
Sincerely
an"Y. Sawyer, REHS/R" S
Public Health Director
cc: Owner
File
Environmental Consultant
JAMES M.KAVANAUGH,P.E. ®Engineering Consultant
14 Shady Hill Drive ® Septic System Designs
North Reading,MA 01864 ® Construction Services
Tel./Fax(978)664-2925 .Custom Home Builder
December 20, 2004
Board of Health
Town of N. Andover
27 Charles Street
N. Andover, MA 01845
Att: Susan Sawyer
Re: Septic System Design
80 Patton Lane
Ms. Sawyer:
Please find enclosed 3 revised copies of a proposed plan for the upgrade of an existing septic
system located at 80 Patton Lane, N. Andover. The revisions on the plan address items within
your December 6, 2004 letter. Please contact me if you cannot locate or require further
explanation any of the revisions to the plan.