Loading...
HomeMy WebLinkAboutMiscellaneous - 81 SAW MILL ROAD 7/30/2003 CHE CKLIST FOR NORTH ANDOVER SEPTIC SYSTEM PLANS Job The following is a checklist that incorporates all Title 5 and local regulations for septic plans. Name of Applicant; Name of Designer:--"" w, Revision Date: Date of Review: Plan Date: Property Address: Map: 10J,j °": Lot: .a BOH Reviewer: ' i '"k Type of Plan(new or upgrade): 4 Number of Bedrooms in Assessor's Records: gpd)Garbage Disposal Allowed: General Information: N.A.=North Andover Septic Regulations Other numbers refer to Title 5 OK,f Problem N/A Street number and map/lot-220(4)(u) - Maximum scale of 1 "=40'for p p O lot plan 220 4 .,,. _. . Maximum scale of 1 "=20'for profile andcolnponent detarls-220(4) Legal boundaries of the facility being served-220(4)(a) Names of abutters from recent tax map- NA 8.02j Number of bedrooms,design cafes.,-NA 8.02i Name&address of record owner&applicant- NA 8.02k _tea Name&address of designer-NA 8.021 Holder and location of all easements-220(4)(b) Date plan drawn&any revision date- NA 8.02m All dwellings and buildings,existing and proposed-220(4)(c) 0 Location of all existing or proposed impervious areas-220(4)(d) =w All distances on site plan—NA 8.03 a-c +., Elevation of proposed driveway-NA 8.02t X - Location and elevation of foundation drain-NA 8.02y Location and dimensions of the system incl.reserve(new const.)-220(4)(e) ° Limits of excavation of leach area on site plan-NA 8.02z Locus plan-220(4)(t) (Not to scale) North arrow-220(4)(g) Existing and proposed contours-220(4)(g) p Locations and logs of deep holes-220(4)(h) / Locations and logs of percolation tests-220(4)(i) Date(s)of soil testing-220(4)(h)&(i) Existing grade elevation of each deep hole-220(4)(h) � Elevation of percolation tests—N.A. 8.02n Name of approving authority representative-220(4)(h)&(i) Name of soil evaluator-220(4)0) Soil logs and perc test logs match BOH records Locations of waterlines,drains,and subsurface utilities-220(4)(m) Observed and adjusted g.w. elevation in the vicinity of the system-220(4)(n) ^'w Complete profile of the system to scale-220(4)(o),NA 8.02c 'r Cross section of leaching facility-NA 8.02w (Not to scale) Location of benchmark(s)within 50-75 feet of facility-220(4)(q) Note listing all variance requests with proper citations-220(4)(p) Local upgrade approval request form submitted-403(1) ` 2 Original IL8./P.Bstamp, signature&date-200&(2) P. discipline specified within stamp. M8LC. /l2a. 8lM stc. supplies hw/in400%pub. wells hw/in 250l pvt. wells(Win ]50l- Location of watercourses,vretlauds,wells, etc. v/in 150'of system-NA 8.03r Wetlaoddischiuer-NA 8.02s BlB plan reference&c certification rcguired(orop|lu000ihucko)-22O/3l Plan contains designer's certification statement | Use approvals/standards checked for I6\system-DBPdoom., | Perorate>30NIPI-not allowed for new,LDA for upgrade-245(1)&c('3) Pmcnxte> 60Mv{-must use nmuifiedtight tank or11d technology-245/W Proposed system qualifies as "shared"system-002(definitions) Flow io over 2,000gyd'NuIl.S. allowed-22OU) Design flow was set iu accordance w�bcode' `03 Existing system lnouduuoudoctuoopruyoruhundoouzout-354 � Leaching facility o[least l` above Base Flood elevation-NA9.05 | All piping So64O minimum-N\ }O.Ol Basement floor minimum |" above groundwater e|evation-NA 5.04 Foundation | ---- -�-�-- --- | � On-site Soil and Groundwater Review / OK Problem N/A | -' Proper deep observation hole logs ou plan-22V(4)04 All deep holes and percs shown,including aborted tests-NA8.O3u � Soil evaluation forms submitted within 6O days of field work-Ul8(%) ��opxzperoo1utinnt�m�\uA'22O(4)(8 -�r- ------ ---' ' ' Ample deep observation holes iu primary disposal area(minimum 2)- 102(2) Ample deep observation holes in secondary disposal area(minimum 2)- lO2(2) ' �m�|�p��testing(uu�luummbd�apooalur�u3 �upr�a �200U�pd) 104(4) ^ ` , . , ' - Deep hole testing conducted within two years-N47.05 Hole Identification Numbers: ground elevation el. � acceptable soil el. ZO � Leach faci|dvinvert el. w/ ground water el. refusal el. ?V1 5f bottom of leach facility el. thickness n[acceptable soil before&after soil B&DL ����� ------- ------- ------ ' �� aep��iuuto��u��� __� 7,, separation turefusal 17 ------_ -----__ _____ | soil class � 2 3 f pert rate � loading rate septic tank below g.w.table (yes or no) pump tank below g.w. table (yes or no) l.f in fill -255(l) Setback Distances(Given in feet) 15.21 1 YES yNO-�' Is the lot in the Lake Cochiewick Watershed? NA 6.00&5.02 OIL Problem N/A Septic'Tank Leach Facility Property line 10 10 Cellar wall 10 20 Inground pool 10 20 Slab foundation 1.0 10 Deck,on footings,etc. 5 10 Waterline 10 10 Private drinking well 75 100 Irrigation well 75 100 Wetlands 75 100 Public well 400 400 Wetlands bordering surface 150 150 water Supply or trib. (in Watershed) L " Trib. To Surface Water supply 325 325 Reservoirs 400 400 Tributaries to reservoirs 200 200 Drains(wat. supply/trib.) 50 100 Drains(intercept g.w.) 25 50 Foundation drains 10 20 Drains(Other) 5 10 jJ= Drywells 20 25 Downhill slope 15'to 3:1 slope 3 4 w/o barrier Building Sewer OK Problem N/,A Grease trap required for certain uses(check 230 for details) Pipe diameter listed(4"minimum)-222(1) Pipe schedule listed-222(3) Pipe cast iron or Sch 40 PVC—NA 11.02 Watertight joints specified-222(3)&(4) Pipe laid on compact, fm base-222(5) Pipe laid on continuous grade in straight line-222(7)@ Cleanouts precede all changes in alignment and grade-222(8) Cleanout provided every 100 feet-222(8) Manhole at any 90 degree alignment change-222(8) Invert elevation at building: Invert elevation at septic tank: Length of run: Slope: (minimum of 0.01 -0.02 desired)-222(6) 10' offset to private well or suction line-222(2) Septic Tank OK Problem N/A Tank is accessible-228(3) No structures above tank—(228(3) Tank can accommodate both primary&reserve—NA 9.04 200%of flow(required&provided given. 1500 min.)-220(4)(0&223)(1)(a) 2-3"drop from inlet to outlet-227(5) V ° Minimum of 4`liquid depth-223(2) 3"air space above tees/baffles(minimum)-227(4) 9"air space above flow line(minimum)-227(4) Tees are not to be replaced by baffles-227(1) Tees extend 6"above flow line-227(1) Inlet tee extends 10"below flow line(minimum)-227(6) Outlet tee extends 14"below flow lime(more for deeper tanks)-227(6) Gas baffle installed on outlet-227(4) Access manhole cover above center of tank&each tee(except 2 compart) 228(2) 3-20"manholes-228(2) 1 childproof,24"riser/manhole w/in 6"of final grade if<1000gpd-228(2) Inlet and outlet tees on center line-227(1) Soil compaction below tank specified(if soil is non-native)-221(2) 6"of{=3/4"stone beneath tank specified-221(2)&22 8(1) If> 1,000 gpd AND not a single fam.dwell.must be 2 tks or 2 comp. -223(1)(b) If plan specifies disposal must be 2 tanks in series or 2 compart,tank-223(1)(c) Buoyancy calcs.required if tank at or below water table-221(8) Tank is watertight-221 (1) 9"of cover over tank(minimum)-228(1) H- 10 loading(min.)-H-20 if traffic-226(3) Top of tank<=36"below grade-221(7) All pumping to tank(if applies)in accordance with-229 Tank is set to keep old system in service during install if possible 4 5 Tight Tank(Check here if not present: �� ) OK Problem N/A 500%of design flow or 2000 gallons provided—260(2)(a) 3-20"manholes—228(2) Soil compaction below tank specified(if soil non-native)—221(2) 6"of<=3/4"stone beneath tank specified—221(2)&228(1) Buoyancy calcs.Required if tank at or below water table—221(8) Tank is watertight—221(1) 9"of cover over tank specified(minimum)—228(1) H-10 loading(min.)—H-20 if traffic—226(3) Top of tank<=36"below grade—221(7) All pumping to tank(if applies)in accordance with—229 AN alarm set at 3/5 tank capacity—260(2)(c) Min. 1-24"frame w/cover at finished grade—228(2)(f) Year round access for pumping—228(2)(g) Distribution Bog(Check here if not present: ) OK Problem N/A Inlet elevation: IZ) .JR Outlet elevation: 0: , G) 0.17'drop from inlet to outlet(minimum)-232(3)(b) 6"sump(minimum)-232(3)(e) All outlets at same elevation-232(3)(b) Outlet pipes laid level for first 2 ft.-232(3)(c) Pipe Sch 40-NA 10.01 bNumber of outlets:� Number of laterals: Size of outlets: Inlet baffle/tee min. 1"over outlet invert for all d-boxes-232(3)(a), Soil compaction below distribution box specified(if soil is non-native)-221(2) 6"of stone beneath distribution box specified-221(2) Box is watertight-221 (1) Top of box<=36"below grade-221(7) Buoyancy calculations required if box is at or below water table-221(8) Pump Chamber(Check here if not present: OK Problem N/A Volume specified: Z)62) 220(4)(r) Pump on elevation- 220(4)(r) Pump off elevation: 220(4)(r) Alarm on elevation: 220(4)(r) Number of cycles per day-220(4)(r)(also 254(1)(d)if gravity from d-box) Minimum 2"delivery line to d-box if gravity-254(1)(c) Pressure dosed l.f, if flow>=2,000 gpd-254(1)(a)&254(2)(a) Cycles per day is consistent with chamber volume-23 1 Volume calculations include flowback volume-2') 1(2) 5 6 24 hour storage capacity above pump on elevation-231(2) Number of pumps: 2 if system serves>2 dwelling units-231(6) Capacity of pump(s)- gpm @ 'TDH-220(4)(r) Pump can pass 1 1/4 "solids(minimum)-231(7) Pump controls specified-220(4)(r) Alarm equipment specified-231(2) Alarm is in building and powered on separate circuit from pump-2') 1(9) Pump sequence correct(off-lead on-lag on-alan-n on)-231(8) Pump performance curves included-220(4)(r) Manual operating switch-NA 12.01 Check valve,bleeder hole-NA 12.01 1 childproof,24"riser/manhole to final grade-2'31(5), Soil compaction beneath pump chamber specified(if soil is non-native)-221(2) 6"of<=3/4"stone beneath chmbr. specified-221(2)&228(1), Buoyancy calculations if chamber is at or below water table-221(8)@ 9"of cover over chamber(minimum)-228(1) H- 10 loading(min.)-H-20 if traffic-226(')), Chamber is watertight-221 (1) Top of chamber<=36"below grade-221(7) Leaching Facility(general-complete for all designs) OK Problem N/A 50%larger if garbage disposal-240(4) L Trenches to be used whenever possible-240(6) L No vehicle or imperv. area above 1.£unless unavoidable-240(7);NA 13.02 Vented if under impervious cover-241 (1) t-,-'/- Vented through same pipes as distribution system-241 (1)(a) Vent protected from precipitation/animal entry-241 (1)(b) Vent is placed beyond traffic or impervious area-24 1 (1)(c) All lines connected to vent if bed or trenches-241(1)(d) 9" cover over peastone-240(9) Reserve area provided(new construction)-248(1) Reserve 4' from primary leach area—NA 9.04 4'(5'if perc rate<=2 MPI)separation to g.w. -212(a)&(b) 4'(down to 2'with variance or I/A-upgrades only)of natural soil under 11 GW separation is adjusted to highest existing grade if facility cuts into a hillside Pipe slope minimum of 0.005 -251(9) Require 5'removal and replacement if in fill-255(5) Top of leach facility<=36"below grade-221(7) Final grade over 11.minimum 0.02 ft/ft-240(10) Surface&subsurface drainage away from 11 -240(1 1)&245(5) Minimum design flow 440 gpd without deed restriction—NA 13.01 3:1 slope where grading required-255(2) Toe of fill slope stops 5'from property line or swale installed-255(2) Impermeable barrier if<3:1 slope or< 15 feet to—3:1 slope-255(2) Impermeable barrier/retaining wall poured concrete—NA 9.02 Retaining wall stamped by P.E. -255(2)(b) Top of retaining wall>=top of peastone elevation-255(2)(f) 10'offset from edge of leach facility to edge of ret.wall-255(2)(g) Perc test(s)done in most restrictive layer- 104(2) Perc test 4'below leaching elevation—NA 7.06 Design flow listed and required/provided leach area given-220(4)(f) Leach pipes SCH40 PVC—NA 10.01 Leach pipes minimum 4"diameter except for dosed system—NA 14.04 6 7 Leach lines capped,vented,or connected together-251(9) Pressure dosing guidance followed if pressure distribution-254(2)(c), Pressure dosing required over 2,000 gpd or with I/A remedial use-231(1) Leaching Trenches(Check here if not present: ) OK Problem N/A Number of trenches: Minimum of 2 trenches-NA 9.01(2) Depth of trenches(max eff. 2'): -247(l) Width of trenches(2'min.,4'max.): -251 (1)(b) Length of trenches(100'max.): -25 1 (1)(a) Trenches are vented(when>50')-251 (11) Trenches follow contour lines-251(2) Trench spacing 3 times effective width or depth minimum-251 (1)(d) In fill or reserve between trenches, 10'min. -NA 14.01& 14.03 Available leach area given(Min. 500 s.f.)-NA 9.01(2) Bottom=L x W x# = s.f. Sidewall=L x D x# x2= s. f. Effective leach area given Loading factor: Effective area=total area s.f.x LTAR = g/day Effective area is>=design flow of facility being served 2"of 1/8"- 1/2"2x washed peastone.-247(2) Trench depth of 3/4"to 1 1/2"double washed stone-247(1) Leaching Pits(Check here if not present: ) OK Problem N/A #of pits/pit systems: (dosing chamber if>1,231 (1)) Dimensions of each pit or system:L W D Depth of pits(max eff.2'): -253(1)(a) Available leach area given Bottom=L x W x#of systems= s.f Sidewall=L+W x D x 2 x#of systems= s.f. Total area=bottom +sidewall = s.f. Effective leach area given Loading factor: Effective area=total area s.f.x LTAR =_g/day Effective area is>=design flow of facility being served Minimum of 2 pits at least 13'X16'—NA 9.01(3) Distribution for galleries/chmbrs. in trench config. -pipe every 20'-253(6) Distribution for galleries/chmbrs. in bed config.-ea.pipe serves<=40 s.f.-253(6) Spacing-2 times the effective width or depth(the greater)-253(1)(c) 2"of 1/8"- 1 /2"2x washed peastone.-247(2) 3/4"to 1 1/2"double washed stone-247(1) Each pit has at least one 20"access cover.24"CI to grade over 2,000 gpd -253(3) Surrounding aggregate thickness between P(min.)and 4'(max.)-253(l)(b) Vents,if necessary,extend under covers of pit(s)-241 (e) Leach Fields(Check here if not present: ) OK Problem N/A Number of fields: (need dosing chamber if> 1,231 (1)) 7 8 Length(100'max.): -252 (2)(b) Width: Total area:L x W Minimum 900 square feet-NA 9.01(1) Distribution lines connected with solid pipe—NA 15.01 Effective leach area given Loading factor: Effective area=total area s.f x LTAR = g/dav Effective area is>=design flow of facility being served Minimum of two distribution lines-252(2)(a) 6'line separation(max.)-252(2)(d) 4'maximum separation from edge of field to line-252(2)(e) 10'minimum separation between adjacent leach fields-252(2)(f) Between 6"and 12"of 3/4 - 1 1/2"stone beneath field-252(2)(g)&247(2) 2"of 1/8"-1/2"2x washed peastone.-247(2) Final Grading OK Problem N/A Slope over leach area minimum of 0.02 feet/foot—240(10) Grading shall divert drainage away from leach area—240(11) Grading slopes away from dwelling 5/24/01 8