HomeMy WebLinkAboutInspection - 81 SAW MILL ROAD 6/21/2004 MIL L R-F VER CONS UL TING
Septic System ManaBenrent Serfllces
TOWN OF NORTH ANDOVER
SEPTIC SYSTEM CONSTRUCTION NOTES
ADDRESS: 61 Sawmill Rd MAP:104B LOT: 108
INSTALLED: Stewerts Septic
DESIGNER: Peter Mirendi
PLAN GATE: 9/14/2003
SOH APPROVAL DATE ON PLAN: 11/20/2003
DATE OF BED BOTTOM INSPECTION: 5/6/2004
DATE OF FINAL CONSTRUCTION INSPECTION: 6/21/2004
DATE OF FINAL GRADE INSPECTION:
SELECT SYSTEM TYPE Pressure Dosing
COMPONENT SUMMARY FROM PLAN
GALLON TANK= 1500
LOADING OF SEPTIC TANK = H10
GALLON PUMP CHAMBER = 1000
LOADING OF PUMP CHAMBER = H10
TYPE OF SAS = Field
DIMENSIONS AND DETAILS OF SAS: 88x20
SITE CONDITIONS
Inspections
NExisting septic tank properly abandoned
(Internal plumbing all to one building sewer
NTopography not appreciably altered
Comments:
5 Blackburn Center, Gloucester,.Massachusetts 01930-2259
toll wL800:3773044 978.28.2:0014
Page I of 4
MILL RIVER CONSULTING
Septic System Management Services
SEPTIC TANK
❑ Bottom of tank hole has 6"stone base
❑ Weep hole plugged
® 1500 gallon tank has been installed
H-10 loading 2-Piece construction
❑ Water tightness of tank has been achieved
test performed: Visual
® Inlet tee installed, over access port
® Outlet tee (gas baffle or effluent filter) installed,over access port
® 24 inch cover to within 6"of final grade installed over one access port
❑ installed over outlet of tank if effluent filter is present
® Hydraulic cement around inlet&outlet
Comments:
Septic tank/pump chamber is combined tank, not two separate tanks.
PUMP CHAMBER
❑ Bottom of tank hole has 6" stone base
❑ Weep hole plugged
® 1000 gallon Pump Chamber installed
H-10 loading
2-Piece construction
® Inlet tee installed, over access port
® Pump(s) installed on stable base
® Alarm float working
® Pump On/Off float working
® Drain hole in pressure line
® 24 inch cover to within 6"of final grade installed over one access port
® Water tightness of tank has been achieved
Visual testing
® Hydraulic cement around inlet&outlet
Comments:
Zoeller pump specified, Barnes SE 411 used. Installer notified that designer is to provide design specs to
confirm suitability of the pump used on the site.
ADVANCEDTREATMENTTECHNOLOGY
❑ Type of treatment
❑ Installed per manufacturers requirements
❑ All components working in accordance with
manufacturer's requirements
Comments:
n/a
5 Blackburn Center, Gloucester,Massachusetts 01930 2259
taffbve 1.800.3773044 978,282.0014 �`�rl<x�
Page 2 of 4
MILL RIVER CONSULTING
Septic System Management Services
® Installed on stable stone base
❑ Inlet tee(if pumped or >0.08'/foot)
® Hydraulic cement around inlet&outlets
❑ Observed even distribution
❑ Speed levelers provided (not required)
Comments:
SOIL ABSORPTION SYSTEM
® Bottom of SAS excavated down to C soil layer, as provided on plan
® Size of SAS excavated as per plan
❑ Title 5 sand installed, if specified on plan
® 3/4-1 1/2"double washed stone installed
® 1/8-1/2" (peastone)double washed stone installed
® laterals installed and ends connected to header(and
vented if impervious material above)
❑ Orifices @ 5&7 o'clock positions
❑ Gravelless disposal systems: type, number and location as per plan
® Elevations of laterals installed as on approved plan
® 40 Mil HOPE barrier installed
❑ Retaining wall (boulder/concrete/timber/ block)
❑ Final cover as per plan
Comments:
PRESSURE DISTRIBUTION
❑ inch manifold
❑ laterals installed with end sweeps
size:
material:
❑ Squirt test ft in height
❑ Equal distribution to all laterals
❑ orifice size inch as per plan
Comments:
n/a
CONTROLPANEL
❑ Alarm&Pump are on separate circuits
® Alarm sounds when float is tripped
❑ Location of control panel: Basement
❑ Rated for exterior if placed outside
Comments:
5 Blackburn Center, Gloucester,Massachusetts 01930-2259
toll&ee 1.800.3773044 978.282.0014 err. �rr , . °��rryecer � r'raar�r
Page 3 of 4
Septic ,,'ysrem Management Services
SYSTEM ELEVATIONS
Benchmark: 103.66
Rod at Benchmark: 2.66
Height of Instrument: 106.52
INVERT"ON DESIGN PLAN INVERT ELEVATION
Building Sewer OUT
Septic Tank IN 101.38 100.85
Septic Tank OUT 101.51 100.22*
Pump Chamber IN 100.22
Pump Chamber OUT
Distribution Box IN 102.58 102.80
Distribution Box OUT 102.40 102.62
Manifold
Lateral 1 HIGH 102.40 102.64
Lateral 1 LOW 102.18 102.41
Lateral 2 HIGH 102.40 102.62
Lateral 2 LOW 102.18 102.41
Lateral 3 HIGH 102.40 102.68
Lateral 3 LOW 102.18 102.40
Lateral 4 HIGH 102.40 102.66
Lateral 4 LOW 102.18 102.39
Lateral 5 HIGH 102.40 102.63
Lateral 5 LOW 102.18 102.38
Lateral 6 HIGH 102.40 102.66
Lateral 6 LOW 102.18 102.41
Comments:
*This is a two-compartment tank--orifice between compartments sometimes varies in size
5 Blackburn Center, Gloucester,Massachusetts 01930 2259
tollfree 1.800.3773044 978.282.0014aea�c� � �ry«, r �l "" . .�
Page 4 of 4