Loading...
HomeMy WebLinkAboutCertificate of Compliance - 41 CEDAR LANE 10/30/2014 � STLEb� 0 • PUBLIC HEALTH DEPARTMENT Town of North Andover Community Development Division CERTIFICATE COMPLIANCE As of: 10/30/2014 This is to certify that the individual subsurface disposal system received a SATISFACTORY INSPECTION of the: Repair Complete By: James Boraczek At: 41 Cedar Lane n �` North r MA 01845 Th� I'Liance of this certifi�cat sh�ll not be Anstrued as a guarantee that the system will function satisfactorily. /Michele Grant � Public Heal th Agent 1600 Osgood Street,North Andover,Massachusetts 01845 Phone 978.688.9540 Fax 978.688.8476 Web www.iovnofnorthandover.com s ° North Andover Health Department Community Development Division QNSITE WASTEWATER Y T M CONSTRUCTION NOTES LOCATION INFORMATION ADDRESS: 41 Cedar Lane MAP: 106.A LOT: 0146 INSTALLER: James Borachek DESIGNER: PLAN DATE: BOH APPROVAL DATE ON PLAN: INSPECTIONS D-Box INSPECTION: 10/28/14 DATE OF BED BOTTOM INSPECTION: DATE OF FINAL CONSTRUCTION INSPECTION: DATE OF FINAL GRADE INSPECTION: SITE CONDITIONS ❑ Contractor reports any changes to design plan ❑ Existing septic tank properly abandoned ❑ Internal plumbing all to one building sewer ❑ Topography not appreciably altered Comments: SEPTIC TANK ❑ Building sewer in continuous grade, on compacted firm base ❑ Cleanouts per plan ❑ Bottom of tank hole has 6" stone base ❑ Weep hole plugged ❑ 1500 gallon tank has been installed H-10 loading ❑ Monolithic tank construction ❑ Water tightness of tank has been achieved by visual testing ❑ Inlet tee installed, centered under access port ❑ Outlet tee installed, centered under access port (gas baffle/effluent filter) ❑ inch cover to within 6" of finish grade installed over one access port ❑ Hydraulic cement around inlet & outlet Comments: PUMP CHAMBER ❑ Bottom of tank hole has 6" stone base ❑ Weep hole plugged ❑ 1500 gallon Pump Chamber installed ❑ H-10 loading ❑ Monolithic tank construction ❑ Inlet tee installed, centered under access port ❑ Pump(s) installed on stable base ❑ Alarm float working ❑ Pump On/Off floats working ❑ Separate on/off floats ❑ Drain hole in pressure line ❑ cover at final grade installed over pump access port ❑ Water tightness of tank has been achieved by testing ❑ Hydraulic cement around inlet & outlet Comments: CONTROLPANEL ❑ Alarm & Pump are on separate circuits ❑ Alarm sounds when float is tripped ❑ Location of control panel: basement ❑ Alarm signal located inside: basement Comments: DISTRIBUTION-BOX Installed on stable stone base m ❑ H-20 D-Box ( � .... .. ❑ Inlet tee (if pumped or >0.0$/foot) ❑ 6Y Hydraulic cement around inlet & outlets ° Observed even distribution _. ❑ Speed levelers provided (not required) � 610, Schedule 40 PVC Pipe Comments: " Y21,11 uI ad,