HomeMy WebLinkAboutCorrespondence - 919 GREAT POND ROAD 8/19/2003 Town of North Andover
Office of the Planning Department "
a� uwa
a �a
Community Development and Services Divisi®n
27 Charles Street a Via°
North.Andover,Massachusetts 01845c&
iwoods@townofnorthandover.com
( )
Planning Director: 978
http://www.townofnorthandover.com P 688-9535
J.Justin Woods F (978) 688-9542
MEMORANDUM
TO: Planning Board
FROM: J.Justin Woods,Planning Director
CC: Heidi Griffin,Community Development&Services Director
Timothy B.McIntosh,P.E.,Vanasse Hangen Brustlin,Inc.
RE: 919 Great Pond Road Watershed Application-ACM Development,L.L.0
DATE: July 31,2003
SECTION 3 ZONING DISTRICTS AND BOUNDARIES
The parcel of land is located within the Watershed Protection District of Lake Cochichewick. VHB correctly
assumed that the site is also in the Residence 1 (R-1)District. The applicant stated that the parcel is in the R-2
district,and that has been indicated on the application for Watershed Special permit. From the zoning map it
appears the lot is in R-1 and the Building Commissioner has confirmed that the lot falls in the R-1 District.
SECTION 4.136 WATERSHED PROTECTION DISTRICT
Section 2—Boundaries and Zones: The Non-Discharge Zone needs to be correctly labeled on the plan.
Section 3—Uses and Requirements: The Applicant's engineer should show calculations that the proposed
additional area and recharge system have been sized appropriately. To accomplish this,the Applicant's engineer
needs to provide runoff and infiltration calculations to Planning Staff and VHB.
Section 4-viii:—Special Permit Requirements: The Applicant's engineer has provided a certification that
addresses the downstream wetland within the Lake Cochichewick watershed. The Applicant's engineer needs to
revise the certification to address the waters of Lake Cochichewick directly.
SECTION 7 DIMENSIONAL REQUIREMENTS
Section 7.1-Lot Area: This lot is within the R-1 district and the parcel does not meet the minimum lot area
requirement as shown in Table 2 of the North Andover Zoning Bylaws. As this is an existing lot,it is subject to
the requirements of section 9.1.
Section 7.4—Building Heights: The Applicant needs to submit architectural plans to review this section for
CGENERAL nce wi--th tie- tovin'Suildin height requirement.
COMMENTS proposed pit system should be routinely inspected and cleaned. `Atr apes and maintenance s hedule
uld be submitted to insure that debris frarn the roof is removed from the pit. Given the location of the fit
acent to the proposed driveway,the proposed pit should specify an H-20 slab/caves to prevent injury an
id damage to the system.Applicant's engineer needs to provide,soil test data to show cgmpliance with BMPs as required,to
nning Staff and VHB
RECOMMENDATIO
Planner recommends continuing the hearing until August 19,2003 and directing the applicant to resolve these
outstanding issues.
BOARD OP APPEALS 688-9541 BUILDING 688-9545 CONSERVATION 688-9530 HEALTH 688-9540 PLANNING 688-9535
lop RECEIVED
MERRIMACK ENGINEERING SERVICE INC.
PROFESSIONAL ENGINEERS ! LAND SURVEYORS ® -PLANNERS A 0 7 2 0��_�
66 PARK STREET•ANDOVER.MASSACHUSETTS 01810•TEL(978)47535$$.373 1 FAX(978)475-1448•E-MAJU ma TeA9 @Qa.com
N0WH ANN r)V_' �
� l NIN r Pr t4�IIPu FC t4T
August 6, 2003
Mr. Justin Woods
Town Planner
Town of North Andover
Planning Department
27 Charles Street
North Andover,MA 01845
RE: 919 Great Pond Road
Dear Mr. Woods:
During the initial public hearing on the subject, the Board re nested certain information be
presented for review at the next scheduled meeting(contin ce granted to the August 19,
2003 scheduled public hearing), This information is provid , as follows:
1. The increase of impervious area, from existing onditions to proposed
conditions,has been computed to be 954 sq feet, as indicated in the
calculations previously submitted. This incre is due primarily to the proposed
front porch with a covered roof(342 sq. ft)an new pavement for vehicle
parking on the side of the garage (414 sq_ ft.). "nee the garage area is proposed
over a portion of the existing paved driveway, i additional impervious area of
only 198 sq, ft. will be realized. The existing t tal impervious area is
approximately 2400 square feet. There will be 40%increase in impervious
area.
2. The gross floor area of the existing dwelling is omputed, as follows:
Basement: 585 sq.
First Floor: 930 sq.
Second Floor: 725 sq. L
The current gross floor area is computed to be ,240 sq. ft. The proposed
addition includes the following additional gro I floor areas:
Great RoQm over Garage 525 sq.
Master Bedroom over
"Bump Out" 263 sq.
i
RECEIVED
Mr.Justin Woods AUG 7 2003
August 6, 2403
NOR`i`I-1 LNG"rOt/C-;
Page 2 PLANNING CdGr-„"r+AR'!NW—INU
The"finished"gross floor area is computed to b 3,028 sq. ft. This represents
an increase of 35.2%in the gross floor area. H ever,within the Non-
Discharge Buffer Zone,it is our understanding it the size of the proposed
expansion is not regulated as in the Non-Dis cc Zone,where an expansion
of more than 25%of gross floor area is prohibit 1.
Please feel free to contact me should you have any questions - comments.
Very truly yo
MERRIMACK NGINBERING SERVICES
Robert C.Dale PT.
Civil/Project E ineer
cd
cc; Andrew Matses
(ACM Development Co.)
I'.
C
{
k
b
d
I
C
MERRIMACK ENGINEERING SERVICES.INC.
66 PARK STREET•ANDOVER MASSACHUSEM 10
MERRIMACK ENGINEERING SERVICES, INC,
PROFESSIONAL ENGINEERS 0 LAND SURVEYORS 0 PLANNERS
66 PARK STREET-ANDOVER, MASSACHUSETTS 01810-TEL(978)475-3555,373-5721 -FAX(978)475-1448- E-MAIL:merreng@aol.com
August 6, 2003
Mr. Justin Woods
Town Planner
Town of North Andover
Planning Department
27 Charles Street
North Andover, MA 01845
RE: 919 Great Pond Road
Dear Mr. Woods:
During the initial public hearing on the subject, the Board requested certain information be
presented for review at the next scheduled meeting (continuance granted to the August 19,
2003 scheduled public hearing). This information is provided, as follows:
1. The increase of impervious area, from existing conditions to proposed
conditions, has been computed to be 954 square feet, as indicated in the
calculations previously submitted. This increase is due primarily to the proposed
front porch with a covered roof(342 sq. ft.) and new pavement for vehicle
parking on the side of the garage (414 sq. ft.), Since the garage area is proposed
over a portion of the existing paved driveway, an additional impervious area of
only 198 sq. ft. will be realized. The existing total impervious area is
approximately 2400 square feet. There will be a 40%increase in impervious
area.
2. The gross floor area of the existing dwelling is computed, as follows:
Basement: 585 sq. ft.
First Floor: 930 sq, fl.
Second Floor: 725 sq. ft.
The current gross floor area is computed to be 2,240 sq. ft. The proposed
addition includes the following additional gross floor areas:
Great Room over Garage 525 sq. ft.
Master Bedroom over
"Bump Out" 263 sq. ft.
Mr, Justin Woods
August 6, 2003
Page 2
The "finished" gross floor area is computed to be 3,028 sq. ft. This represents
an increase of 35.2% in the gross floor area, However, within the Non-
Discharge Buffer Zone, it is our understanding that the size of the proposed
expansion is not regulated as in the Non-Disturbance Zone, where an expansion
of more than 25% of gross floor area is prohibited.
Please feel free to contact me should you have any questions or comments.
Very truly yours,
MERRIMACK ENGINEERING SERVICES
Robert C. Daley, P.E.
Civil/Project Engineer
cd
cc: Andrew Matses
(ACM Development Co.)
MERRIMACK ENGINEERING SERVICES,INC.
66 PARK STREET-ANDOVER,MASSACHUSETTS 01810
MERRIMACK ENGINEERING SERVICES, INC.
PROFESSIONAL ENGINEERS ® LAND SURVEYORS ® PLANNERS
66 PARK STREET•ANDOVER,MASSACHUSETTS 01810•TEL(978)475-3555,373-5721 •FAX(978)476-1448•E-MAIL:merreng @aol.com
July 31, 2003
Town of North Andover `
Planning Board
27 Charles Street
North Andover, MA 01845
RE: 919 Great Pond Road
Dear Members of the Board,
As requested by Vanesse Hangen Brustlin, Inc. (VHB), this letter is written to emphasize to
the Planning Board that there will be no detrimental impact to the downstream wetland nor to
Lake Cochichewick. The roof run off will be collected and recharged into a leaching pit to
provide recharge to the groundwater. The driveway run off will be directed into a proposed
grass-lined swale which will serve to filter out any potential pollutants prior to entering the
wetland which is greater than 150 feet away from the driveway.
Please contact our office should you have any questions or comments.
Very truly yours,
MERRIMACK ENGINEERING SERVICES
obert C. Daley,P.E.
Project/Civil Engineer
cd
cc: Andrew Matses
Timothy McIntosh-VHB
MERRIMACK ENGINEERING SERVICES, INC.
PROFESSIONAL ENGINEERS ® LAND SURVEYORS • PLANNERS
66 PARK STREET•ANDOVER,MASSACHUSETTS 01810•TEL(978)475-3555,373-5721 •FAX(978)475-1448•E-MAIL:merreng @aol.com
July 25, 2003
Town of North Andover
Planning Board
27 Charles Street
North Andover, MA 01845
RE: 919 Great Pond Road
Dear Members of the Board,
As requested by Vanesse Hangen Brustlin, Inc. (VHB), this letter is written to emphasize to
the Planning Board that there will be no detrimental impact to the downstream wetland
within the Lake Cochichewick watershed. The roof run off will be collected and recharged
to the groundwater. The driveway run off will be directed into a proposed grass-lined swale
which will serve to filter out any potential pollutants prior to entering the wetland which is
greater than 150 feet away from the driveway.
Please contact our office should you have any questions or comments.
Very truly yours,
MERRIMACK ENGINEERING SERVICES
Robert C. Daley, P.E.
Proj ect/Civil Engineer
cd
cc: Andrew Matses