HomeMy WebLinkAboutCorrespondence - 1476 SALEM STREET 5/29/2012 GRADY CONSULTING , L . L . C .
......».,.......imsacwio..............................—...............�,��..m.,,,�.�....,....,,oa,�,�...,.,�w..w.w......�....,..�.. ..,.,....�..,�..�..�......—....„,.,.�,,..ww_..........�m_w..� —,,,...—»....�..—...—.�..�...m..,�..,...
.•nummm� oirvrmimumunmirvrvmmmmorvnrvmammm mmummm norrvnannnnnimnnnninnnniry msi
Registered Professional Civil Engineers
May 29, 2012
Susan Sawyer, REHS/RS "°
Public Health DirectorkJrv ^�
Health Department
1600 Osgood Street
Building 20-Suite 2-36
North Andover, MA 01845
RE: #1476 State Street— Septic System Repair
Applicant—Albert Koenig
Dear Susan and Board Members:
Enclosed please find three (3) sets of revised plans for the above referenced property. The
plan was revised in response to a telephone call and letter from Susan Sawyer dated May 21,
2012. Plan revisions and our response to comments are as follows.
1. As we discussed it was our opinion that there are four (4) bedrooms in this home per
the Title 5 definition of a bedroom. The Title 5 Inspection Report dated March 27,
2012 also notes that there are four(4) bedrooms on page 6 of the report. We have
provided a floor plan sketch as discussed.
2. A scaled system profile of 1"=10' horizontal and 1"=1' vertical has been provided as
requested.
3. The effluent loading rate has been changed to 0.53 gpd/sf as requested. As a result
there is one additional chamber per row in the soil absorption system.
4. The location of the percolation test has been added to the plan as requested.
5. The"Greenhouse” is set on the ground with cinder blocks around the perimeter and a
dirt floor. For design purposes we have treated this as a slab foundation and is located
ten (10) feet from the leaching facility. A separation distance has been noted on the
plan as requested. The floor of the Greenhouse is above the leaching chambers so the
ten (10) foot separation is appropriate.
6. We have added a notation to TH 2 showing the point where the depth measurements
were taken from. The reason the measurements were taken from this point is that this
is the highest el-ration where mottling was observed.
7. A note has been added to the plan stating the building sewer is to be laid on a
"compacted firm base" and as straight as possible as requested.
8. The slope of the building sewer has been revised from 0.019 to 0.020 as requested.
9. The plan has been revised to plan to depict the tees in the septic tank to be centered
under the manholes as requested.
10. A note has been added to the plan stating the effluent tee filter is to be cleaned and
maintained on an annual basis as requested.
71 Evergreen Street, Suite 1 * Kingston,MA 02364 * Tel (781) 585-2300 * Fax (781) 585-237$
11. Buoyancy calculations have been provided as requested. These were initially omitted
as the nearest test hole shows no water at elevation 98.75 and the bottom of the
lowest tank is at approximately elevation 99.8. For the purposes of this calculation we
assumed groundwater at elevation 101.7 per the test hole farthest from the tanks.
12. The note on the distribution box has been revised to indicate a riser within 9" of final
grade as requested.
13. The profile has been revised to depict a 2" force main as requested.
14. The plan has been revised to depict a swale to direct surface waters around the
dwelling as requested.
If you have any questions please do not hesitate to contact us.
Sincerely,
GRADY CONSULTING, L.L.C.
Richard Grad ,`P.E.
Principal Engineer
CC: Albert Koenig
c/o Wind River Environmental
70 Batzak Drive
Holliston, MA 01746
H AGC\2012\12-072\bohletter.doc
BUOYANCY CALCULATION
1500 GALLON SEPTIC TANK
Job No.: 12-072
Location: 1476 Salem Street, North Andover
1500 Gallon Monolithic Pump Chamber
-See Attached Drawings
Buoyant Force of Tank
10.21' X 6.125' X 0.8' X 62.4 #/cf = 3,122 # 1
Weight of Tank = 12,000 #
Weight of Soil
Over Anti-Flotation
(74.5 in X 2 X 4.25 in) + (132 in X 2 X 4.75 in) = 1887.25 sq in
13.1 sf
13.1 sf X 6.1 ft X 85#/cf = 6792.35 # 1
Over Tank
10.21 X 6.125 X 1.5' X 85#/cf = 7973 #
Weight of Tank+ Soil
12000#+7973#=" 19,973 #
> Buoyant Force-ANTI-FLOTATION COLLAR NOT REQUIRED
page 1 of 2
123-1/2'
116-10
r—�^ ------------ _—_--_---
1 F
I t Three 20112"Dis
Cleanout Lids
{ I
1
1
84" 74112" 67-112" L
------ -----------------
t
1 1
i {
t t
I I
1 t
1 I
A% Three 4"Dia.inlets T1vee 4"Dia.Outlets
108.0 4"
101.7
105.45 LIQUID LEVEL u
67"
54-112'
4$" 51-112"
.r
'La
_�.:;.E.,
132°
"CAFr!IFtt'd11t>a1C��`�Pt RA lu+iT't=.'Q� -
[1) Concrete strength rc 4,000 PSI Q 28 days. Density 150 PCF
[21 Cement,Portland Type I or IIJ. ASTM C150-81
(3) Admixtures,air&plastkAzars 0 ASTM 0233-82.
[4J Reinforcing ASTM A615 for Wire fabric.Grade 60 bar.
[5] Design loading H-10(see H2O Tanks).
16j Construction joints sealed with Butyl Rubber
1500 tuDtvO(1)
page 2 of 2
Page 2 of 2
41
FM/5
Fu,j5/Fm/d 14 230 Sq* 14 6
7 24 Sqft 22
26
�1
I S-t 6
'B Roo
ruxr
F
j
1
I
a.
t
4
E
y
{
y
t I
t
f
i
3
f
EE
F+V
I
{
5/22/2012
DelleChiaie, Pamela
From: DelleChiaie, Pamela
Sent: Monday, June 18, 2012 11:37 AM
To: 'rick @gradyconsulting.com'
Cc: Sawyer, Susan
Subject: Septic Plan Approval - 1476 Salem Street, North Andover
Attachments: 20120618105530257.pdf
Attached is the plan review approval for 1476 Salem Street,North Andover. The original was mailed to the
homeowner.
Pamela DelleChiaie
Health Department
'Town of North Andover,
1600 Osgood Street I Bldg.20 1 Suite 2-36
North Andover,MA 01845
Phone 978.688.9540
Fax 978.688.8476
Email gl!�c, i to w.rnofnorth an_dover.corn
Web www.TownoMorthAndover.ccom
1
/ ^/ f f
fe;�'`,o � ' /�
�"� r
North Andover Health Department
Community Development Division
June 15, 2012
Albert Koenig
1476 Salem Street
North Andover, MA 01845
RE: Subsurface Sewage Disposal System Plan for 1476 Salem Street, North Andover,
Massachusetts Map 106A lot 149
Dear Mr. Koenig,
The North Andover Board of Health has completed the review of the septic system design plans,
for the above referenced property, submitted on your behalf by Grady Consulting LLC, dated
May 1, 2012, last revised on May 22, 2012 and received June 5, 2012. The design has been
approved for use in the construction of a replacement onsite septic system for a 4-bedroom
design. This plan is generally good for 3-years from the date of approval however as this is for a
repair system this is reduced to 2- years.
During this time, a licensed septic system installer must obtain a permit and complete this work,
and a Certificate of Compliance be endorsed by the installer, designer and the Town of North
Andover. In the event an imminent health problem such as sewage backup into the dwelling is
occurring, the North Andover Board of Health may reduce the time period for which this plan is
valid.
This approval is also subject to the following conditions:
1. If site conditions are found in the field to be different from those indicated on the
design plan and/or soil evaluation, the originally issued Disposal System Construction
Permit is void, installation shall stop, and the applicant shall reapply for a new
Disposal Systems Construction Permit (3 10 CMR 15.020(1)).
2. It is the responsibility of the applicant and/or the applicant's septic system designer,
septic system installer or other representative to ensure that all other state and
Page 1 of 2
North Andover Health Department, 1600 Osgood Street, Building 20, Suite 2-36,
North Andover, MA 01845 Phone: 978.688.9540 fax: 9 78.688.8476
1476 Salem Sheet June 15, 2012
municipal requirements are met. These may include review by the Conservation
Commission,Zoning Board, Planning Board, Building Inspector, Plumbing Inspector
and/or Electrical Inspector. The issuance of a Disposal System Construction Permit
shall not construe and/or imply compliance with any of the aforementioned
requirements.
Your effort to provide a properly functioning septic system for your dwelling is greatly
appreciated. The Health Department may be reached at 978-688-9540 with any questions you
might have.
Sine ely,
S sawyer, S
ublic ealth Dire for
cc: Richard Grady, Grady Consulting
file
Page 2 of 2