HomeMy WebLinkAboutMiscellaneous - 1476 SALEM STREET 9/18/2012 $ f
:f'
PUBLIC WEALTH DEPARTMENT
(oonnonity Develonmenf Division
TOWN OF NORTH ANDOVER
SEPTIC DISPOSAL SYSTEM—INSTALLATION CERTIFICATION
The undersigned hereby certify that the Sewage Disposal System (Aonstructed;( )repaired;
(Print Name)
Located at: ------
-
(Installation Address)
Was installed in conformance with the North Andover Board of Health approved plan,originally dated
?.. ,.. and last revised on �C with a design flow of
--
gallons per day. The materials used were in conformance with those specified on the
approved plan;the system was installed in accordance with the provisions of 310.CMR 15.000,Title 5 and local
regulations,and the final grading agrees substantially with the approved plan.All work is accurately represented on
the As-built which has been submitted to the Board of Health.
Bottom of Bed Inspection Date:
// Engineer Representative(Signature)
And—Print Name
Final Construction Inspection Date:
Engineer Representative(Signature)
7
And—Print Name
Installer: �� uc �k/ -., - (Signature) _ Date: e t /�2)261 9--
And—Print Name
Enginer: w (Signature) Date:
And—Print Name
1600 Osgood Street, North Andover, Alossuchusetts 01845
Phone 978.688.9540 Fax 978.688.8476 Wei) http://www.townofnorthandover.com
GRAp III. . _-RWIW IM CONSULTING. L . L
Registered Professional Civil EngineersI __
October 4, 2012
Susan Sawyer, REHS/RS
Public Health Director "
Health Department
1600 Osgood Street
Building 20-Suite 2-36
North Andover, MA 01845
RE: As-built Certification—41476 Salem Street
Dear Susan and Board Members:
Enclosed please find two copies of the revised as-built plan. The plan has been revised to
show a tie table as requested.
If you have any questions please do not hesitate to call.
Sincerely,
GRADY CONSULTING,L.L.C.
F ""
W'I I(RD Fir,
.1. rn#
� erg
Richard" rally, P. is"e�!\l1Y�, 3,3072
Principal Engineer
cc: Albert Koenig
c/o Wind River Environmental
70 Batzak Drive
Holliston, MA 01746
IIAGC\2012\12-072\Asbui1t cert.doc
71 Evergreen Street, Suite 1 * Kingston, MA 02364 Tel (781)585-2300 Fax (781) 585-2378
AS-BUILT CHECKLIST
l All changes to the design plan have been reflected on the as-built
Is of suitable scale;(one inch=40 feet or fewer for plot plans and one inch=20 or fewer for details of system
components)
Lot number, Street Name,Assessors Map and Parcel Number
Lot Lines and Location of Dwellings served by the system
Locations&Dimensions of system,including reserve(if applicable)
Ties to dwelling or Permanent Structure
a.From Septic Tank `) G' t�` ' ` e—
b.From Leach Area
Ties to Lot Lines from leach area
Locations of Deep Holes&Peres
i Elevations of Disposal System
Top of Foundation Elevation
j/ Locations of Wells,Drains,Watercourses within 150 feet of system
6/ Location of water,gas,electric lines, cable
Distances from Corners of House to Center of Tank&D-Box
Location of Structures within 6 Inches of Finished Grade
Original Stamp&Signature
Location and holder of any easements which could impact the system
Impervious Areas;Driveways,etc
North Arrow
Location&Elevations of Benchmark used
STATEMENT ON PLAN(NA 5.3)
"I certify the locations, elevations, ties, cover material, exposed component covers etc. shown on this as-built
substantially agree with the approved plan and have determined that the break out elevations, if applicable, have
been met."
Signature of Designer Date
or, if a STUCTURAL WALL IS PRESENT(NA 4.9)Letter or statement on the as-built indicating the wall was,
or was not, constructed in accordance with the intended design and any manufacturer's specifications
Signature of Designer Date
As of:Wednesday,April 27,2011
AS-BUILT CHECKLIST
All changes to the design plan have been reflected on the as-built
Is of suitable scale;(one inch=40 feet or fewer for plot plans and one inch=20 or fewer for details of system
components)
Lot number, Street Name,Assessors Map and Parcel Number
Lot Lines and Location of Dwellings se
Locations&Dimensions of system,inc
r5 C
Ties to dwelling or Permanent Structure
a.From Sepi
b.From Lea e"K
Ties to Lot Lines from leach area
Locations of Deep Holes&Percs
Elevations of Disposal System
Top of Foundation Elevation
Locations of Wells,Drains, Watercourses within 150 feet of system
Location of water,gas,electric lines,cable
Distances from Comers of House to Center of Tank&D-Box
Location of Structures within 6 Inches of Finished Grade
Original Stamp&Signature
Location and holder of any easements which could impact the system
Impervious Areas;Driveways, etc
North Arrow
Location&Elevations of Benchmark used
STATEMENT ON PLAN(NA 5.3)
"I certify the locations, elevations, ties, cover material,- exposed component covers etc. shown on this as-built
substantially agree with the approvedplan and have determined that the break out elevations, if applicable, have
been met.
Signature of Designer Date
or, if a STUCTURAL WALL IS PRESENT(NA 4.9)Letter or statement on the as-built indicating the wall was,
f specifications
or was not, constructed in accordance with the intended design and any manufacturer's speci
Signature of Designer Date
As of:Wednesday,April 27,2011
A. 74 D Id CONSULTING , L ro 0 l
Registered Professional Civil Engineers
August 15, 2012
r
WVT14011 k' /kTH�:�rta�a\/8,9
Susan Sawyer, REHS/RS P u,l x� N 1u F��� N�^ ,,,
Public Health Director "
Health.Department
1600 Osgood Street
Building 20-Suite 2-36
North Andover,MA 01845
RE: As-built Certification—#1476 Salem Street
Dear Susan and Board Members:
We hereby certify that we have inspected the septic system at the above referenced address
and the system has been constructed in compliance with 310 CMR 15.000, the approved
design plans and all local requirements, and that any changes to the design plans have been
reflected on the enclosed as-built plans. Enclosed please find two copies of the as-built plan.
If you have any questions please do not hesitate to call.
Sincerely,
GRADY CONSULTING,L.L.C.OAM
,
F81C:HAli1.� rya
a
Richard Grady, Pt. <> C=RADY
Principal Engineer >.
cc: Albert Koenig
c/o Wind River Environmental
70 Batzak Drive
Holliston, MA 01746f °°" ° °
H:\GC\2012\12-072\Asbtfflt cert.doc � ,'.,t
�t
i
u
71 Evergreen Street, Suite 1 * Kingston, MA 0231 (nl
e •
•
•
PUBLIC HEALTH DEPARTMENT
Town of North Andover
Community Development Division
. C
A)TRIEELICAAETE COWPLI3NCE
As of:
5WLe����� '"
This is to certify that the individua(su6surface disposafsystem received a
SA`IISFAC` ORTINS(PEMONof the:
comprete air and d ConStm-ction of an
On-Site Sewage "osa[System
Wiffiam &denhiser
At:
14 76 Sakm Street
210/106.B-0018-0000.0
Map-1 06.(B~tParcef-001 8
01845
7Fie Z su"ance of this certifi' to (taCE�not 6e construed as a guarantee that tFie system willfunction satisfactor Cy.
9KicFiefe E. Grant
Eu
u6CYfeafth Inspector
5VorthAndover9feafth(Department
1600 Osgood Street,North Andover,Massachusetts 01845
Phone 978.688.9540 Fax 978.688.8476 Web www.townofnorthandover.com
DelleChiaie, Pamela
From: Randy Burley [rburley@millriverconsulting.com]
Sent: Wednesday, August 01, 2012 5:03 PM
To: 'Daniel Ottenheimer'; Grant, Michele; 'Isaac Rowe'; 'Marianne Peters'; DelleChiaie, Pamela;
Sawyer, Susan
Subject: 1476 Salem St
I completed the final inspection today with Rodenheiser, checked the numbers onsite and all is well. I am off until
Monday and will prepare the final report then.
The only thing I cautioned him on is the amount cover cannot be more than 3 ft. He acknowledged and said lie is going to
slope the site down near the shed so as not to exceed 3' of cover.
I liked what he did by cementing the inspection ports into the infiltrator and inserting rebar in the cement;this will give
the inspection ports more stability and make them easier to find with a metal detector if they get buried.
Sincerely,
Randy But-ley,Project Manager
Mill River Consulting,Inc.
6 Sargent Street
Gloucester, MA 01930-2719
978-282-0014
fax: 978-282-1318
yen con S k I ltt nVC01-p.
.............
Wriverconsuffiri 0111
............
.11 R."i'ver
consulting
Please riote the Massachusetts Secretary of State's office has detGrrnined that most emails to and from rywriicipal offices arid officials are pUblic records.For wore
information please,refer to:http:.,L/_v��F
�1 5b,L/[e, jqx,..htrn,
_ -
Please consider the onviromnerit before:printing this email.
o °
•
North Andover Health Departiment
Community Development Division
QNSITE WASTEWATER SYSTEM T UCTI NOTES
LOCATION INFORMATI N
ADDRESS: .
f❑ M r MAP: LOT:
INSTALLER "
DESIGNER:
PLAN DATE:
BOH APPROVAL DATE ON PLAN:
INSPECTIONS
TANK INSPECTION, ....._
DATE OF BED BOTTOM INSPECTION: i
DATE OF FINAL CONSTRUCTION INSPECTION:
DATE OF FINAL GRADE INSPECTION:
SITE CONDITIONS
❑ Contractor reports any changes to design plan
❑ Existing septic tank properly abandoned
❑ Internal plumbing all to one building sewer
❑ Topography not appreciably altered
Comments:
SEPTIC TANK
❑ Building sewer in continuous grade,krn .
<"compactedefirm-base �.�
Cleanouts per plan
Bottom of tank hole has 6" stone base
Weep hole plugged
�. ❑ � i z gallon tank has been installed
loading
°" Monolithic tank construction
Water tightness�....,❑ g Hess of tank has been achieved by
testing
°� .. ❑�.��.µ � Inlet tee installed, centered under access port
❑ Outlet tee installed, centered under access port
(gas baffle/effluent filter)
❑ inch cover to within 6" of final grade
installed over one access port
❑ Hydraulic cement around inlet & outlet
Comments:
PUMP CHAMBER
Bottom of tank hole has 6" stone base
Weep hole plugged
12 (X'-dallon Pump Chamber installed
❑ '1-1,& loading
olithic tank construction
Inlet tee installed, centered under access port
❑ Pump(s) installed on stable base
❑ Alarm float working
❑ Pump On/Off floats working
❑ Separate on/off floats
❑ Drain hole in pressure line
❑ cover at final grade installed over pump
access port
❑ Watertightness of tank has been achieved by
testing
❑ Hydraulic cement around inlet & outlet
Comments:
CONTROLPANEL
❑ Alarm & Pump are on separate circuits
❑ Alarm sounds when float is tripped
❑ Location of control panel: basement
❑ Alarm signal located inside: basement
Comments:
DISTRIBUTION-BOX
❑ Installed on stable stone base
❑ H-20 D-Box
❑ Inlet tee (if pumped or >0.08'/foot)
❑ Hydraulic cement around inlet & outlets
❑ Observed even distribution
❑ Speed levelers provided (not required)
Comments:
4
SOIL ABSORPTION SYSTEM (General)
Bottom of SAS excavated down to C soil layer,
as provided on plan
❑ Size of SAS excavated as per plan
ti❑-._. Title 5 sand installed, if specified on plan
❑ 40 Mil HDPE barrier installed
❑ Laterals installed and ends connected to
header (and vented if impervious material
above)
❑ Elevations of laterals and chambers installed as on
approved plan
❑ Retaining wall (boulder/ concrete /timber/block)
❑ Final cover as per plan
Comments:
SOIL ABSORPTION SYSTEM (Gravel-less Chambers)
❑ Brand and Model of Chamber: Standard Quick
4 Infiltrator Chambers
❑ Number of chambers per row:
❑ Number of rows (trenches):
Comments: Total Chambers =
BM =
HR =
HI =
SYSTEM ELEVATIONS
ROD AS-BLT INVERT DESIGN INVERT
ELEVATION ELEV ELEV
Benchmark
Building Sewer OUT
Septic Tank IN
Septic Tank OUT
Pump Chamber IN
Pump Chamber OUT
Distribution Box IN
Distribution Box OUT
Lateral 1 TOP
Lateral 1 INVERT
Lateral 2 TOP
Lateral 2 INVERT
Lateral 3 TOP
Lateral 3 INVERT
Lateral 4 TOP
Lateral 4 INVERT
Lateral 5 TOP
Lateral 5 INVERT
Lateral 6 TOP
Lateral 6 INVERT
Top of Chamber
Bottom of Bed/Chamber
SKETCH PLAN
CRITICAL SETBACK DISTANCES
Mark those distances checked in the field against the design plan and regulatory
setback
Tank SAS Sewer
® Property line 10 10 --
® Cellar wall 10 20 --
® Inground pool 10 20 --
® Slab foundation 10 10 --
® Deck, on footings, etc 5 10 --
® Waterline 10 10 101
® Private drinking well 75 1002 50
® Irrigation well 75 100
® Surface Water 25 50
® Bordering Vegetated Wetland ,
Salt Marsh, Inland/Coastal Bank3 75 100
® Wetlands bordering surface
water supply or trib. (in Watershed) 150 150
® Trib.to surface water supply 325 325
® Public well 400 400
® Interim Wellhead Prot.Area
® Reservoirs 400 400
® Drains (wat. supply/trib.) 50 100
® Drains (intercept g.w.) 25 50
® Drains (Other)Foundation 10 (5) 20(10)
® Drywells 20 25
1 Suction line 222(2)
2 100 feet is a minimum acceptable distance and no variance is allowed for a lesser distance(NA 5.02).
3 As defined in 310 CMR 10.55, 10.32, 10.54,and 10.30,respectively,pursuant to 15.211(3),also by NA
wetland bylaws