HomeMy WebLinkAboutTitle V Inspection Report - 475 WINTER STREET 6/17/2011 Commonwealth of Massachusetts
0A Title 5 Official Inspection F
Subsurface Sewage Disposal System Forma Not for VoluntaTASS
475 Winter Street
.....................
Property Address
Richard Peterson TOWN OF NORTH ANDOVER
--------------
----------------
Owner Owners Name jHiE-A1.TK0r-.rARTMENT—'
information is required for North Andover —---------- -MA 01845 6/17/2011
every page. City/Town State Zip Code Date of Inspection
Inspection results must be submitted on this form. Inspection forms may not be altered in any
way. Please see completeness checklist at the end of the form.
Important:
When filling out A. General Information
forms on the
computer, use I Inspector:
only the tab key
to move your Neil J. Bateson
cursor-do not Name of Inspector —---------- ------------
use the return
key, Bateson Enterprises Inc, ——----------------- --
Company Name
VQ 111 Argilla Road -—------- ---- —------------------
Company Address
Andover ---------- ------------ Ma --------------............. 01810
City/Town State Zip Code
978-475-4786 S115
Telephone Number License Number
B. Certification
I certify that I have personally inspected the sewage disposal system at this address and that the
information reported below is true, accurate and complete as of the time of the inspection. The inspection
was performed based on my training and experience in the proper function and maintenance of on site
sewage disposal systems. I am a DEP approved system inspector pursuant to Section 15.340 of
Title 5(310 CMR 15.000). The system:
Passes ❑ Conditionally Passes ❑ Fails
❑ Needs Further Evaluation by the Local Approving Authority
.............
6/17/2011
Ins-�ci 1 es ignature� Date
4�1
The system inspector shall submit a copy of this inspection report to the Approving Authority(Board
of Health or DEP)within 30 days of completing this inspection. If the system is a shared system or
has a design flow of 10,000 gpd or greater, the inspector and the system owner shall submit the
report to the appropriate regional office of the DER The original should be sent to the system owner
and copies sent to the buyer, if applicable, and the approving authority.
****This report only describes conditions at the time of inspection and under the conditions of use
at that time.This inspection does not address how the system will perform in the future under
the same or different conditions of use.
t5ins;•09106 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 1 of 17
Commonwealth of Massachusetts
Title I Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
475 Winter Street
Property Address
Richard Peterson
Owner Owner's Name
information is
required for North Andover MA 01845 6/17/2011
every page. Cityrrown State Zip Code Date of Inspection
B. Certification (cont.)
Inspection Summary: Check A,B,C,D or E/always complete all of Section D
A) System Passes:
® 1 have not found any information which indicates that any of the failure criteria described
in 310 CMR 15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are
indicated below.
Comments:
After permit from B.O.H., install new outlet tee& pipe repair, inspection from B.O.H., septic sysyem
now passes Title 5 Inspection.
B) System Conditionally Passes:
❑ One or more system components as described in the"Conditional Pass"section need to be
replaced or repaired. The system, upon completion of the replacement or repair, as approved by
the Board of Health, will pass.
Check the box for"yes", "no" or"not determined" (Y, N, ND)for the following statements. If"not
determined," please explain.
The septic tank is metal and over 20 years old* or the septic tank(whether metal or not) is
structurally unsound, exhibits substantial infiltration or exfiltration or tank failure is imminent. System
will pass inspection if the existing tank is replaced with a complying septic tank as approved by the
Board of Health.
*A metal septic tank will pass inspection if it is structurally sound, not leaking and if a Certificate of
Compliance indicating that the tank is less than 20 years old is available.
❑ Y ❑ N ❑ ND (Explain below):
t5ins•09/08 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 2 of 17
Commonwealth of Massachusetts � II
Us
u Subsurface Sewage Disposal System Form Not for Voluntary Assessments
475 Winter Street
Property Address
Richard Peterson
Owner Owner's Name 01845 5/31/2011
information is North Andover MA
required for every City Town State Zip Code Date of Inspection
page.
Inspection results must be submitted on this form. Inspection forms may not be altered in any
way. Please see completeness checklist at the end of the form. y rz i
Q
important:When A. General Information
filling out forms �
on the computer,
use only the tab 1. Inspector: k 11 JE 6 1 i[)E, f 4�ANDOVER
8"�
key to move your i 9l °1 f kl i�d�II`
cursor-do not Neil J. Bateson
use the retyrn Name of Inspector
key. Bateson Enterprises Inc.
Company Name
111 Ar illa Road
Company Address 01810
Andover Ma
State
Cityfrown
Yip Code
978-475-4786 S 11
Telephone Number License Number
B. Certification
I certify that I have personally inspected the sewage disposal system at this address and that the
information reported below is true, accurate and complete as of the time of the inspection. The inspection
was performed based on my training and experience in the proper function and maintenance of on site
sewage disposal systems. I am a DEP approved system inspector pursuant to Section 15.340 of
Title 5(310 CMR 15.000).The system:
❑ Passes ® Conditionally Passes ❑ Fails
❑ Needs Further Evaluation by the Local Approving Authority
y
5/31/2011
Inspe or' Signature Date
The system inspector shall submit a copy of this inspection report to the Approving Authority(Board
of Health or DEP)within 30 days of completing this inspection. If the system is a shared system or
has a design flow of 10,000 gpd or greater, the inspector and the system owner shall submit the
report to the appropriate regional office of the DEP. The original should be sent to the system owner
and copies sent to the buyer, if applicable, and the approving authority.
****This report only describes conditions at the time of inspection and under the conditions of use
at that time.This inspection does not address how the system will perform in the future under
the same or different conditions of use. G
Title 5 official Inspection Form:Subsurface Sewage Disposal System-Page 1 of 17
t5ins•09108
Commonwealth of Massachusetts
Title 5 official Inspection Form
Subsurface Sewage Disposal System Form Not for Voluntary Assessments
475 Winter Street
Property Address
Richard Peterson
Owner Owner's Name
information is North MA 01845 5/31/2011
h A
required for every Nort A State Zip Code Date of Inspection
page.
B. Certification (cont.)
Inspection Summary: Check A,B,C,D or E/always complete all of Section D
A) System Passes:
J
❑ I have not found any information which indicates that any of the failure criteria described
in 310 CMR 15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are
indicated below.
Comments:
B) System Conditionally Passes:
® One or more system components as described in the"Conditional Pass" section need to be
replaced or repaired. The system, upon completion of the replacement or repair, as approved by
the Board of Health,will pass.
Check the box for"yes", "no"or"not determined" (Y, N, ND)for the following statements. If"not
determined," please explain.
The septic tank is metal and over 20 years old*or the septic tank(whether metal or not) is structurally
unsound, exhibits substantial infiltration or exfiltration or tank failure is imminent. System will pass
inspection if the existing tank is replaced with a complying septic tank as approved by the Board of
Health.
*A metal septic tank will pass inspection if it is structurally sound, not leaking and if a Certificate of
Compliance indicating that the tank is less than 20 years old is available.
❑ Y ® N ❑ ND (Explain below):
Title 5 Official Inspection Form:Subsurface Sewage Disposal system•page 2 of 17
t5ins•09108
Commonwealth of Massachusetts
Title 5 official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
M 475 Winter Street
Property Address
Richard Peterson
Owner Owner's Name
information is North Andover MA 01845 5/31/2011
required for every State Zip Code Date of Inspection
page. City�rown
B. Certification (cont.)
B) System Conditionally Passes (cont.):
❑ Observation of sewage backup or break out or high static water level in the distribution box due
to broken or obstructed pipe(s)or due to a broken, settled or uneven distribution box. System will
pass inspection if(with approval of Board of Health):
❑ broken pipe(s)are replaced ❑ Y ® N ❑ ND (Explain below):
❑ obstruction is removed ❑ Y ® N ❑ ND (Explain below):
❑ distribution box is leveled or replaced ❑ Y ® N ❑ ND (Explain below):
❑ The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The
system will pass inspection if(with approval of the Board of Health):
❑ broken pipe(s)are replaced ❑ Y ® N ❑ ND (Explain below):
- ❑ obstruction is removed ❑ Y ® N ❑ ND (Explain below):
C) Further Evaluation is Required by the Board of Health:
❑ Conditions exist which require further evaluation by the Board of Health in order to determine if
the system is failing to protect public health, safety or the environment.
1. System will pass unless Board of Health determines in accordance with 310 CMR
15.303(1)(b)that the system is not functioning in a manner which will protect public health,
safety and the environment:
❑ Cesspool or privy is within 50 feet of a surface water
❑ Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh
Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 3 of 17
l5ins•09/08
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form Not for Voluntary Assessments
475 Winter Street
Property Address
Richard Peterson
Owner Owner's Name
information is North Andover MA 01845 5/31/2011
required for every State Zip Code Date of Inspection
page Cityrrown
B. Certification (cont.)
2. System will fail unless the Board of Health (and Public Water Supplier, if any)
determines that the system is functioning in a manner that protects the public health,
safety and environment:
❑ The system has a septic tank and soil absorption system (SAS) and the SAS is within
100 feet of a surface water supply or tributary to a surface water supply.
❑ The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water
' supply.
❑ The system has a septic tank and SAS and the SAS is within 50 feet of a private water
supply well.
❑ The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or
more from a private water supply well**.
Method used to determine distance:
**This system passes if the well water analysis, performed at a DEP certified laboratory, for coliform
bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or
less than 5 ppm, provided that no other failure criteria are triggered. A copy of the analysis must be
attached to this form.
3. Other:
Outlet tee in septic tank&replace drop box with pipe
D) System Failure Criteria Applicable to All Systems:
You must indicate"Yes" or"No"to each of the following for all inspections:
Yes No
Backup of sewage into facilty or system component due to overloaded or
El z 4
clogged SAS or cesspool
El due or ponding of effluent to the surface of the ground or surface waters
due to an overloaded or clogged SAS or cesspool
❑ ® Static liquid level in the distribution box above outlet invert due to an overloaded
or clogged SAS or cesspool
E3 ® Liquid depth in cesspool is less than 6" below invert or available volume is less
than '/2 day flow
Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 4 of 17
(sins•09/08
Commonwealth of Massachusetts
Title 5 official Inspection Form
Subsurface Sewage Disposal System Form Not for Voluntary Assessments
475 Winter Street
Property Address
Richard Peterson
Owner Owner's Name
information is MA 01845 5/31/2011
required for every North Andover State Zip Code Date of Inspection
page. Cityfrown
B. Certification (cont.)
Yes No
❑ ® Required pumping more than 4 times in the last year NOT due to clogged or
obstructed pipe(s). Number of times pumped:
❑ ® Any portion of the SAS, cesspool or privy is below high ground water elevation.
❑ ® Any portion of cesspool or privy is within 100 feet of a surface water supply or
tributary to a surface water supply.
❑ ® Any portion of a cesspool or privy is within a Zone 1 of a public well.
❑ ® Any portion of a cesspool or privy is within 50 feet of a private water supply well.
❑ ® Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet
from a private water supply well with no acceptable water quality analysis. [This
system passes if the well water analysis, performed at a DEP certified
laboratory,for fecal coliform bacteria indicates absent and the presence
Of ammonia nitrogen and nitrate nitrogen is equal to or less than 5 ppm,
provided that no other failure criteria are triggered.A copy of the analysis
and chain of custody must be attached to this form.]
❑ ® The system is a cesspool serving a facility with a design flow of 2000gpd-
10,000gpd.
El ® The system fails. I have determined that one or more of the above failure
criteria exist as described in 310 CMR 15.303, therefore the system fails. The
system owner should contact the Board of Health to determine what will be
necessary to correct the failure.
E) Large Systems: To be considered a large system the system must serve a facility with a
design flow of 10,000 gpd to 15,000 gpd.
For large systems, you must indicate either"yes"or"no"to each of the following, in addition to the
questions in Section D.
Yes No
❑ ❑ the system is within 400 feet of a surface drinking water supply
❑ ❑ the system is within 200 feet of a tributary to a surface drinking water supply
❑
El Area system is located in a nitrogen sensitive area (Interim Wellhead Protection
Area—IWPA) or a mapped Zone II of a public water supply well
If you have answered"yes"to any question in Section E the system is considered a significant threat,
or answered"yes" in Section D above the large system has failed. The owner or operator of any large
system in accordance withi310tCMR 15 304.Section E or failed under
em owner should Section D shall
the appropriate rithe
system m accord
regional office of the Department.
Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 5 of 17
(sins•09108
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form Not for Voluntary Assessments
475 Winter Street
Property Address
Richard Peterson
Owner Owner's Name
information is North Andover MA 01845 5/31/2011
required for every State Zip Code Date of Inspection
page Cityfrown
C. Checklist
Check if the following have been done. You must indicate"yes" or"no" as to each of the following:
Yes No
® ❑ Pumping information was provided by the owner, occupant, or Board of Health
❑ ® Were any of the system components pumped out in the previous two weeks?
® ❑ Has the system received normal flows in the previous two week period?
Have large volumes of water been introduced to the system recently or as part of
❑ ® this inspection?
® ❑ Were as built plans of the system obtained and examined? (If they were not
available note as N/A)
® ❑ Was the facilityor dwelling inspected for signs of sewage back up?
® ❑ Was the site inspected for signs of break out?
® ❑ Were all system components, excluding the SAS, located on site?
® ❑ Were the septic tank manholes uncovered, opened, and the interior of the tank
inspected for the condition of the baffles or tees, material of construction,
dimensions, depth of liquid, depth of sludge and depth of scum?
® ❑ Was the facility owner(and occupants if different from owner) provided with
information on the proper maintenance of subsurface sewage disposal systems?
The size and location of the Soil Absorption System (SAS) on the site has
been determined based on:
® ❑ Existing information. For example, a plan at the Board of Health.
❑ Determined in the field (if any of the failure criteria related to Part C is at issue
®
approximation of distance is unacceptable) [310 CMR 15.302(5)]
D. System Information
Residential Flow Conditions:
4 4
Number of bedrooms (design): Number of bedrooms(actual):
DESIGN flow based on 310 CMR 15.203 (for example: 110 gpd x#of bedrooms):
440
Title 5 official Inspection Form:Subsurface Sewage Disposal system•Page 6 of 17
l5ins-09108
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
475 Winter Street
Property Address
Richard Peterson
Owner Owner's Name
information is North Andover MA 01845 5/31/2011
required for every State Zip Code Date of Inspection
page. City/Town
D. System Information
Description:
4
Number of current residents:
Does residence have a garbage grinder? ❑ Yes ® No
Is laundry on a separate sewage system? [if yes separate inspection required] ❑ Yes ® No
Laundry system inspected? ❑ Yes ❑ No
Seasonaluse? ❑ Yes ® No
Yes
Water meter readings, if available(last 2 years usage(gpd)):
Detail:
Sump pump? ❑ Yes ® No
Current
Last date of occupancy: Date
Commercial/Industrial Flow Conditions:
Type of Establishment:
Design flow(based on 310 CMR 15.203): Gallons per day(gpd)
Basis of design flow(seats/persons/sq.ft., etc.):
Grease trap present? - ❑ Yes ❑ No
Industrial waste holding tank present? ❑ Yes ❑ No
Non-sanitary waste discharged to the Title 5 system? ❑ Yes ❑ No
Water meter readings, if available:
Title 5 Official Inspection Forth:Subsurface sewage Disposal System-Page 7 of 17
l5ins•09/08
Commonwealth of Massachusetts
Title Official Inspection r
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
475 Winter Street
Property Address
Richard Peterson
Owner Owner's Name
information is North Andover MA 01845 5/31/2011
required for every State Zip Code Date of Inspection
page Cityrrown
D. System Information (cont.)
Last date of occupancy/use: Date
Other(describe below):
i
i
i
I
General Information
Pumping Records:
Pumped two years ago, owner
Source of information:
Was system pumped as part of the inspection? ® Yes ❑ No
1000
If yes, volume pumped: gallons
How was quantity pumped determined?
Measured tank
Inspect tank&tees
Reason for pumping:
Type of System:
® Septic tank, distribution box, soil absorption system
❑ Single cesspool
❑ Overflow cesspool
❑ Privy
❑ Shared system (yes or no) (if yes, attach previous inspection records, if any)
❑ Innovative/Alternative technology.Attach a copy of the current operation and
maintenance contract(to be obtained from system owner)and a copy of latest
inspection of the I/A system by system operator under contract
❑ Tight tank. Attach a copy of the DEP approval.
❑ Other(describe):
t5ins•09108 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 8 of 17
Commonwealth of Massachusetts
Title ffiillnpeti n r
Subsurface Sewage Disposal System Form Not for Voluntary Assessments
475 Winter Street
Property Address
Richard Peterson
Owner Owner's Name
information is North Andover MA 01845 5/31/2011
required for every State Zip Code Date of inspection
page City/Town
D. System Information (cont.)
Approximate age of all components, date installed (if known) and source of information:
Tank original, d-box&field installed11/22/1988, as built plan
Were sewage odors detected when arriving at the site? ❑ Yes ® No
Building Sewer(locate on site plan):
2
Depth below grade: feet
Material of construction:
® cast iron ®40 PVC ❑ other(explain):
Distance from private water supply well or suction line: feet
Comments (on condition of joints, venting, evidence of leakage, etc.):
4"cast iron thru wall, 3" PVC in house, no leaks visible
-- Septic Tank(locate on site plan):
1
Depth below grade: feet
Material of construction:
® concrete ❑ metal ❑ fiberglass ❑ polyethylene ❑ other(explain)
If tank is metal, list age:- years
Is age confirmed by a Certificate of Compliance? (attach a copy of certificate) ❑ Yes ❑ No
Tx5'x4'
Dimensions:
5"
Sludge depth:
Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 9 of 17
t5ins•09108
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form Not for Voluntary Assessments
475 Winter Street
Property Address
Richard Peterson
Owner owner's Name
information is North Andover MA 01845 5/31/2011
required for every State Zip Code Date of Inspection
page Cityrrown
D. System Information (cont.)
Septic Tank(cont.)
Distance from top of sludge to bottom of outlet tee or baffle
22"
6"
Scum thickness
Distance from top of scum to top of outlet tee or baffle
8" '
I
14"
Distance from bottom of scum to bottom of outlet tee or baffle
Tape measure
How were dimensions determined?
Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity,
liquid levels as related to outlet invert, evidence of leakage, etc.):
Pumped septic tank. Inlet baffle ok. Outlet tee partially corroded off, needs to be replaced.
Depth of liquid at outlet invert No evidence of leakage.
Grease Trap(locate on site plan):
Depth below grade: feet
Material of construction:
❑ concrete ❑ metal ❑ fiberglass ❑ polyethylene ❑ other(explain):
Dimensions:
Scum thickness
Distance from top of scum to top of outlet tee or baffle
Distance from bottom of scum to bottom of outlet tee or baffle
Date of last pumping: Date
Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 10 of 17
t5ins•09/08
Commonwealth of Massachusetts
Title 5 Official Inspection Form
a
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
M 475 Winter Street
Property Address
Richard Peterson
Owner Owner's Name
information is North Andover MA 01845 5/31/2011
required for every State Zip Code Date of Inspection
page. City/Town
D. System Information (cont.)
Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity,
liquid levels as related to outlet invert, evidence of leakage, etc.):
Tight or Holding Tank(tank must be pumped at time of inspection) (locate on site plan):
Depth below grade:
Material of construction:
❑ concrete ❑ metal ❑fiberglass ❑ polyethylene ❑ other(explain):
Dimensions:
Capacity: gallons
Design Flow: gallons per day
Alarm present: ❑ Yes ❑ No
Alarm level: Alarm in working order: ❑ Yes ❑ No
Date of last pumping: Date
Comments (condition of alarm and float switches, etc.):
*Attach copy of current pumping contract(required). Is copy attached? ❑ Yes ❑ No
Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 11 of 17
t5ins-09108
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form -Not for Voluntary Assessments
475 Winter Street
Property Address
Richard Peterson
Owner Owner's Name
information is North Andover MA 01845 5131/2011
required for every State Zip Code Date of Inspection
page CityrTown
D. System Information (cont.)
Distribution Box(if present must be opened) (locate on site plan):
0
Depth of liquid level above outlet invert
Comments(note if box is level and distribution to outlets equal, any evidence of solids carryover, any
evidence of leakage into or out of box, etc.):
Drop box has carryover&side is collapsing. Needs to be replaced with pipe. D-box level &
distribution equal, has flow levelers. No evidence of leakage. Evidence of carryover, pumped d-box to
clean.
Pump Chamber(locate on site plan):
Pumps in working order: ❑ Yes ❑ No
Alarms in working order: ❑ Yes ❑ No
Comments(note condition of pump chamber, condition of pumps and appurtenances, etc.):
Soil Absorption System (SAS) (locate on site plan, excavation not required):
If SAS not located, explain why:
Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 12 of 17
t5ins•09108
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
a 475 Winter Street
Property Address
Richard Peterson
Owner Owner's Name
information is Nth Andover MA 01845 5/31/2011
North required for every State Zip Code Date of Inspection
page. City/Town
D. System Information (cont.)
Type:
❑ leaching pits number:
❑ leaching chambers number:
❑ leaching galleries number:
❑ leaching trenches number, length:
® leaching fields number, dimensions:
1 field 23' x 35'
❑ overflow cesspool number:
❑ innovative/alternative system
Type/name of technology:
Comments (note condition of soil, signs of hydraulic failure, level of ponding, damp soil, condition of
vegetation, etc.):
Soil ok Vegetation ok No sign of ponding to surface.
Cesspools (cesspool must be pumped as part of inspection) (locate on site plan):
Number and configuration
Depth—top of liquid to inlet invert
Depth of solids layer
Depth of scum layer
Dimensions of cesspool
Materials of construction
Indication of groundwater inflow ❑ Yes ❑ No
t5ins-09108 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 13 of 17
Commonwealth of Massachusetts
Title 5 Official Inspection Form
o Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
M 475 Winter Street
Property Address
Richard Peterson
Owner Owner's Name
information is North Andover MA 01845 5/31/2011
required for every State Zip Code Date of Inspection
page. Cityrrown
D. System Information (cont.)
Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation,
etc.):
Privy(locate on site plan):
Materials of construction:
Dimensions
Depth of solids
Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation,
etc.):
t5ins•09/08 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 14 of 17.
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
475 Winter Street.
Property Address
Richard Peterson
Owner Owner's Name
information is
required for every North Andover MA 01845 5/31/2011
page. CitylTown State Zip Code Date of Inspection
D. System Information (cont.)
Sketch Of Sewage Disposal System: Provide a view of the sewage disposal system, including ties to
at least two permanent reference landmarks or benchmarks. Locate all wells within 100 feet. Locate
where public water supply enters the building. Check one of the boxes below:
® hand-sketch in the area below
❑ drawing attached separately
a 7
p �= L46
u
0(b
7( t 1
—1�
t5ins-09108 Title 5 Official Inspection Form:Subsurface Sewage Disposal System•Page 15 of 17
Commonwealth of Massachusetts
Title ffi i I Inspection Form
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
475 Winter Street
Property Address
Richard Peterson
Owner Owner's Name
information is North Andover MA 01845 5/31/2011
required for every State Zip Code Date of Inspection
page. Cityrrown
D. System Information (cont.)
Site Exam:
® Check Slope
® Surface water
: ® Check cellar \
® Shallow wells
>4
Estimated depth to high ground water: feet
Please indicate all methods used to determine the high ground water elevation:
® Obtained from system design plans on record
If checked, date of design plan reviewed: 11/5/1975 Date
❑ Observed site (abutting property/observation hole within 150 feet of SAS)
® Checked with local Board of Health -explain:
Design plan
❑ Checked with local excavators, installers-(attach documentation)
❑ Accessed USGS database-explain:
You must describe how you established the high ground water elevation:
As per original design plan
Before filing this Inspection Report, please see Report Completeness Checklist on next page.
t5ins•09108 Title 5 Official Inspection Forth:Subsurface Sewage Disposal System•Page 16 of 17
Commonwealth of Massachusetts
Title Official Inspection r
Subsurface Sewage Disposal System Form-Not for Voluntary Assessments
475 Winter Street
Property Address
Richard Peterson
Owner Owner's Name
information is North Andover MA 01845 5/31/2011
page
required for every CitylTown state Zip Code Date of Inspection
E. Report Completeness Checklist
• Inspection Summary: A, B, C, D, or E checked
• Inspection Summary D (System Failure Criteria Applicable to All Systems) completed
• System Information-Estimated depth to high groundwater
® Sketch of Sewage Disposal System either drawn on page 15 or attached in separate file
l5ins•09108 Title 5 Official Inspection Form:Subsurface Sewage Disposal System-Page 17 of 17
Commonwealth of Massachusetts
City/Town of
System Pumping r
Form.4
DEP has provided this form for use by local Boards of Health. Other forms may be used, but the
information must be substantially the same as that provided here. Before using this form, check with your
local Board of Health to determine the form they use.The System Pumping Record must be submitted to
the local Board of Health or other approving authority.
A. Facility Information
1. System Location: Left front of house, right front of house, left side of house, right side of house, Left
rear of house, right rear of house, left side of building, right rear of building, under deck.
qq
City/Town State Zip Code
2. System Owner:
Name
Address(if different from location)
City/Town State Zip Code
Telephone Number
B. Pumping Record
1. Date of Pumping 2. Quantity Pumped: Gallons
Date
3. Type of system: ❑ Cesspool(s) Eg- epank ❑ Tight Tank
❑ Other(describe):
4. Effluent Tee Filter present? ❑ Yes to If yes, was it cleaned? ❑ Yes ❑ No
5. Condition of System: J�
6. System Pumped By:
Neil J. Bateson F5821
Name Vehicle License Number
Bateson Enterprises Inc.
Company
7. Locaf where contents.were disposed:
L.S. Lowell ste ter
I AUA
Signaflurg oftlauler Date
t5form4.doce 06/03 System Pumping Record.Page 1 of 1
t`
Summary Record Card generated on 5/19/2011 2:35:48 PM by Lisa Evans Page'
Town of North Andover
Tax Map # 210-104.A-0083-OOQO.0
Parcel Id 16310
475 WINTER STREET
RICHARD PETERSON
HOLLY PEPLER
475 WINTER STREET
NORTH ANDOVER, MA 01845
Class 101 Single Family Property Type 1 Residentia
Size Total 1.04 Acres
FY 2011
UB Mailing Index
Name/Address Type Loan Number Active/Inact. From Until
RICHARD PETERSON Owner
HOLLY PEPLER
475 WINTER STREET
NORTH ANDOVER,MA 01845
GRANDIOUX,BERNARD Previous Customer Inactive 4/2/2007
475 WINTER STREET
N.ANDOVER,MA
01845
UB Account Maint.
Account No Cycle Occupant Name Active/Inactive
Bldg Id. 18011.0-475 WINTER STREET Last Billing Date 4/6/2011
3180040 03 Cycle 03 Active
UB Services Maint.
Account No.3180040
Service Code Rate Charge Multiplier/Users
MISCFEE ADMIN FEE 0.635/8 7.82 1/
WTR WATER 01 ALL METER SIZE 92.65 /1
UB Meter Maintenance
Account No.3180040
Serial No Status Location Brand Type Size YTD Cons
32938990 a Active 00 b Badger w Water 0.63 0.63 422
Date Reading Code Consumption Posted Date Variance
3/15/2011 611 'a Actual 23 4/13/2011 -220/c
12/14/2010 588 a Actual 29 1/12/2011 -580/c
9/16/2010 559 a Actual 73 10/15/2010 116%
6/14/2010 486 a Actual 32 7/15/2010 760/c
3/17/2010 454 a Actual 19 4/14/2010 -30%
12/14/2009 435 a Actual 26 1/12/2010 -38°k
9/16/2009 409 a Actual 46 10/15/2009 42%
6/10/2009 363 a Actual 28 7/20/2009 65%
3/17/2009 335 a Actual 19 4/29/2009 -13%
12/12/2008 316 a Actual 20 1/20/2009 -690/c
9/16/2008 296 a Actual 72 10/10/2008 800/c
6/10/2008 224 a Actual 36 7/16/2008 112%
3/14/2008 188 a Actual 17 4/11/2008 -270/c
12/17/2007 171 a Actual 25 1/22/2008 -460/c
9/14/2007 146 a Actual 42 10/12/2007 38%
6/20/2007 104 a Actual 29 7/20/2007 1520/c
3/30/2007 75 f Final Bill 15 3/30/2007 -21%
12/13/2006 60 a Actual 15 1/19/2007 -41%
9/19/2006 45 a Actual 27 10/20/2006 45%
6/20/2006 18 a Actual 18 7/10/2006 -100%
3/24/2006 0 n New Meter 0 4/17/2006 -100%