HomeMy WebLinkAboutApplication - 202 LACY STREET 7/11/1964 1i0C: t , Daniel,, Jr. I':�cy APPLICATION FOR SEWAGE DISPOSAL INSTALLATION HEALTH DEPARTMENT _, NORTH ANDOVER, MASS. I hereby make application for a permit for a sewage disposal installation at .� c Street . I will install this system in ac- cordance with all the laws of the Commonwealth of Massachusetts and regulations of the Board of Health of the Town of North Andover. Further, I will construct the house sewer of bell and spigot pipe, the minimum diameter being 4 inches, and will maintain a minimum grade of 1/ until 10 :feet pre- ceding the septic tank, where the grade shall not exceed 2%. I will install a con- crete septic tank of in size. A manhole (s) permitting easy cleaning will be provided with removable cover (s) of iron or concrete within 12 inches of the ground surface. I will provide subsurface disposal field with 4 inch perforated or open jointed pipe and laid in a series of trenches, the bottom of which will pro- side a minimum of _ 2 :.0 lineal (+ , , a :) feet of effective absorption area. The pipes will be laid on a-6 inch layer of washed gravel or crushed stone ranging in size from 3/4 to 1-1/2 inches (dia. ) and the pipes will be surrounded by similar material to a height of 2 inches above the crown of the pipe. The joints of these pipes will be protected from clogging and before filling the trench, 2 inches of gravel. or stone 1/81, to 1/4" (dia.) will. be placed over the course gravel or stone. The disposal field will be installed at a grade of 4 to 6 inches/100 feet. No single the line will exceed 100 feet in length and in any case, two lines of tale will be installed. A minimum of 6 feet will be maintained between the center lines of the disposal field trenches and the average depth of trench shall not exceed 36 inches. No part of the installation will be less than 100 feet from any private water supply, 25 feet from any stream, 20 feet from any dwelling or 10 feet from any property line. I further agree not to cover and onion of this installation until a roved b th1 inspbction officer, as provided below, and to incorporate any additional requirements that may be attached to the permit. Flat Plans must be submitted with application. DATE g plagant I hereby issue the above permit for the Hoard of I-Iealhof the Town of North Andover, Massachusetts. DATE ^ Sigature of Health Agent I have inspected the uncovered system indicated above and find everything done as described. DATE g Signature off", .nspecting Officer Percolation Test " rain,. Soil: Sandy clay Garbage Grindero No BOARD OF HEALTH TOWN OF NORTH ANDOVER, MASS. d r i 4 1. NAME DATE 1, 2. ADDRESS LOT NO. TEL. 3. NO. OF BEDROOMS DEN YES NO 4. GARBAGE GRINDER YES NO 5. SHOW DIMENSIONS OF HOUSE 6. SHOW DISTANCES OF HOUSE TO ALL PROPERTY LINES 7. SHOW DIMENSIONS OF LOT 8. SHOW LOCATION AND SIZE OF SEPTIC TANK OR CESSPOOL 9. NOTE LOCATION AND DISTANCE OF WELL FROM SEWERAGE SYSTEM 10. SHOW LOCATION OF BROOKS, STREAMS, DITCHES, LEDGE OUTCROP, ETC. 11. SHOW DISTANCE OF SEPTIC TANK OR CESSPOOL FROM HOUSE NOTE: LOCAL REGULATIONS SHOULD BE READ CAREFULLY. BOARD OF HEALTH OF NORTH ANDOVER, MASSACHUSETTS SEWAGE DISPOSAL DATE January 25 1964 NAME OF LOCATION 1,acy _Street Address of o:E no;. BUILDING: Dwelling ..X _Ot he SYSTEM: New_. X_-- Repair___ GENERAL DESCRIPTION OF LAND__. SUBSOIL: Clay Gravel Sanay, Cl.a�L PERCOLATION TEST I_------Minutes per inch. - - - - -- - - - - - - - - - - - - MINIMUM INSTALLATION RECOMMENDATIONS CONCRETE SEPTIC TANK_ 1-.000 __gallon capacity. LEACH FIELD 200 lineal feet of drain pipe® William J........... D. iscoll , Engideer Board of Health 1 0 TA RO" ad of 1TV111 W, Arth Andovop, Hags. e, L Subdivisic Tnv c s t i gat Obsorver, SOIL PROFILAS) Da t e Da t e, Da be 4. Date A e Elav-. ETA El ev", 0 Ties to Test Pits 12 ....... /T. ()2 120 sto : Top & subsoil depth; Wths of otber soil types ; r 'of water tnble ; of Dates-; ato late DUE, on t e [5 Won of 6"Mme I JET C V� " •,. A)��,1 { i ,�F������ 0 �1��.r G�" 1 �"�I4�F� ��..! p (.��I�� 41�('.°n V .�0"1 2'i. 1 IJi.. `. ,,i 0b'"C' _ . ° �: sn '� ,,, �,.I_C'.'� -{+") fix. "a C.E. � .E"�.� e, h - ` Mafi,J To� 3 �)c> Tr r['c�p ��: �ktrl�w;�E>�._�1.. c]eI, (;��� ; c�,E:;T.>�f�;I�w:,� aF" c:��t�l�,�r::� ���, �.N. "G�/.(�Yr;;:; � iIE,�T:�t,T�t. c��_�i' �nr��.t,E:r.�` �,.� ::_,.ra ; d r.p t;c"I. of r o a u;,a. l Da te; T) it;(; f'_i 't; 1���E:rcIII) �;f,EE11°C., �ys1C,t.1Cf.E �,�iC,1l•E _ of ll, 0 0 J 1101s . Avid V loop '_'U& URFACE DISPOSAL, SYSTEM CHECK LIST NORTH ANDOVER BOARD OF HEALTH APPROVED DATE PROVIDED DISAPPROVED DATE TIME REASON NL Title 5 Reg® 2. 5 Fail OK The submitted plan must show as a minumum: a the lot to be served (area,dimensions ,1_ot ;, abutters) (Planning Board files) b) location and log of deep observation holes-distance to ties location and results of percolation tests--distance to ties design calculations & calculations showing required leaching area ocation and dimensions of system (including reserve area) existing and proposed contours (g location of any wet areas within 100 ' of the sewage disposal system or disclaimer (check wetlands mapping) surface and subsurface drains within 100' of sewage disposal system or disclaimer z) location of any drainage easements within 100' of sewage disposal system or disclaimer (planning board files) known sources of water supply within 200' of sewage disposal system or disclaimer ----(k) location of any proposed well to serve the lot (100' from leaching facility) -location of water lines on property (10' from leaching facilities) ,_ern- --location of benchmark .._._�driveways - garbage disposers no PVC is to be used in construction __kq—)— a profile of the system (elevations of basement , plumber! pipe septic tank, distribution box inlets and outle,'-s , distribution field piping and any other elevations) _ -r) maximum ground water elevation in area of se�,�age disposes_ system s) plan must be prepared by a Professional Engineer or other professional authorized by law to prepare such plans Septic Tanks Reg® 6 (a) Capacities - 150% of flow, water table , tees , depth of tees , access, pumping, Cleanout (c) 10' from cellar wall or inground swimming pool (d) 25 ' from subsurface drains Norlt,h Andover Subsurface (disposal system check list. Page 2 Fail OK Distribution Boxes Rag®10® 2 Slope greater than 4. 08 Rig®10.4 (b) Sump Leaching Pits Leaching pits are preferred where the installation is possible Reg®11 ® 2 -a) Calculations of leaching area (minimum 500 S.F. ) Reg®11 ®4 ) Spacing Reg®11 .1 ) Surface drainage 2% Reg®11 ®11 d) Cover material - Leaching Fields Reg.15,1 (a) NIgGreater than 20 minutes/inch Reg.15®1 (b) Area (minimum 900 S.F. ) Reg®15.4 (c) Construction of field Reg®15®8 (d) Surface drainage 2% Reg® 3.7 (e) 20' from, cellar wall or inground swimming pool Leaching_Trenches Reg.14®1 (a) Calculations of leaching area (mi.n® 500 S.F. ) Reg.14® 3 (b Spacing (4 ft® min® 6 ft® with reserve between) Reg.14®4 (c Dimensions 14. 5 Reg®14.6 (d) Construction Reg®14.? (e) Stone Reg®14®1 (f) Surface drainage 2% Downhill Slope r b) Slope y/x = (to be shown) y/x X 150 = (to be shown) Pum,) Reg® 9®1 (a) Approval Reg. 9®6 (b) Stand-by power i i BOARD OF HEALTH OF NORTH ANDOVER , MASSACHUSETTS SEWAGE DISPOSAL DATE "I 414/70 NAME OF APPLICANT m LOCATION a e . "°��, Tc.>�„ An vec b Address of lot no, BUILDING: Dwelling X Other SYSTEM: New x Repair GENERAL DESCRIPTION OF LAND h:°5 a-ji SUBSOIL: Clay Gravel Sand PERCOLATION TEST 3 —minutes per inch® MINIMUM INSTALLATION RECOMMENDATIONS CONCRETE SEPTIC TANK mJ. CJC)( _gallon capacity: LEACH FIELD— 180 lineal feet of drain pipe. William Jo D i coll , Engineer Board of Health. CONSER17ATION COMMISSION NORTII ANDOVER, AIASSACHUSEWS OI845 .Q E® APFIR 7PN ¢�H k�R�SSgCHU���"� W9„FY4'V114 November 20 , 1978 North Andover Board of Health Town Hall North Andover, Massachusetts 01845 RE: Lot 19-Lacy Street reported as Lot 12-Lacy Street to Board of Health Dear Sirs : The Conservation Commission has received a Notice of Intent under the Wetlands Protection Act for the above referenced lot . During a routine site visit, as part of the responsibilities under the Wetlands Protection Act, a discrepancy was noted between the soil test data report on the subsurface disposal system plan, and an open soil test pit on the site . This plan was submitted to both the Conservation and the Board of Health . Because of the differences noted above, it was con- sidered advisable to inform you of this discrepancy so that you might investigate, if you deem it necessary . Very trVly yours , Vincent S . Turano, Ph.D. Chairman VST/dlp