Loading...
HomeMy WebLinkAboutCertificate of Compliance - 63 HAY MEADOW ROAD 6/6/2014 �� n �aOilriUk d PUBLIC HEALTH DEPARTMENT Town of Forth Andover Community Development Division CERTIFICATE OF COMPLIANCE As of: 6/6/201. 4 This is to certify that the individual subsurface disposal system received a SATISFACTORY INSPECTION of the: Repair of D-Box By-, Todd Bateson At 63 Hay Meadow Road Map 104.B Lot 0097 ort�, Andover, MA 01845 T A .issuance of this c t is to shall no be construed as a guarantee that the system will function satisfactorily. m lvtf Michele Grant K_-J/ Public Health Agent 1600 Osgood Street,North Andover,Massachusetts 01845 Phone 978.688.9540 fax 978.688.8476 Web www.townofnorthandover.corn • North Andover Health Department Community Development Division QNSITE WASTEWATER SYSTEM CONSTRUCTION NOTES LOCATION INFORMATION ADDRESS: 63 Hay Meadow Rd. MAP: 104.13 LOT: 0097 INSTALLER: Todd Bateson DESIGNER: PLAN DATE: BOH APPROVAL DATE ON PLAN: INSPECTIONS TANK INSPECTION: D-box 6/6/14 DATE OF BED BOTTOM INSPECTION: DATE OF FINAL CONSTRUCTION INSPECTION: DATE OF FINAL GRADE INSPECTION: SITE CONDITIONS ❑ Contractor reports any changes to design plan ❑ Existing septic tank properly abandoned ❑ Internal plumbing all to one building sewer ❑ Topography not appreciably altered Comments: SEPTIC TANK ❑ Building sewer in continuous grade, on compacted firm base ❑ Cleanouts per plan ❑ Bottom of tank hole has 6" stone base ❑ Weep hole plugged ❑ 1500 gallon tank has been installed H-10 loading ❑ Monolithic tank construction ❑ Water tightness of tank has been achieved by visual testing ❑ Inlet tee installed, centered under access port ❑ Outlet tee installed, centered under access port (gas baffle/effluent filter) ❑ inch cover to within 6" of finish grade installed over one access port E:1 Hydraulic cement around inlet & outlet Comments: PUMP CHAMBER F-1 Bottom of tank hole has 6" stone base ❑ Weep hole plugged ❑ 1500 gallon Pump Chamber installed ❑ H-10 loading ❑ Monolithic tank construction F-1 Inlet tee installed, centered under access port ❑ Pump(s) installed on stable base ❑ Alarm float working ❑ Pump On/Off floats working F-1 Separate on/off floats ❑ Drain hole in pressure line ❑ cover at final grade installed over pump access port ❑ Watertightness of tank has been achieved by testing ❑ Hydraulic cement around inlet & outlet Comments: CONTROL PANEL ❑ Alarm & Pump are on separate circuits ❑ Alarm sounds when float is tripped ❑ Location of control panel: basement F-1 Alarm signal located inside: basement Comments: DISTRIBUTION-BOX Installed on stable stone base F� H-20 D-Box F-1 Inlet tee (if pumped or >0.08'/foot) ",,-'Hydraulic cement around inlet & outlets Fj Observed even distribution Speed levelers provided (not required) Schedule 40 PVC Pipe Comments: