HomeMy WebLinkAboutAs-Built Plan / Installation Certificate Form - 857 CHESTNUT STREET 6/12/2007 HAT NEW ENGLAND ENGINEERING INVERT ELEVATIONS NSPECTED THE SUBSURFACE SEWAGE STALLED AT 857 CHESTNUT STREET, DESIGN ACTUAL I.THE SYSTEM HAS BEEN CONSTRUCTED :NGINEERING TOLERANCE OF 310 CMR FOUNDATION(HOUSE) 95.31 95.24 1 DESIGN PLANS DATED 8-21-06,REVISED FOUNDATION(CABANA) 95.31 96.03 iAL REQUIREMENTS,EXCEPT AS NOTED TANK IN(HOUSE) 94.50 94.53 TANK IN(CABANA) 94.50 94.52 TANK OUT 94.25 94.35 PUMP IN 94.20 94.15 PUMP OUT 93.95 93.98 D-BOX IN 101.94 101.97 D-BOX OUT 101.77 101.79 A 101.67 101.69 B 101.67 101.59 C 101.67 101.65 D 101.67 101.71 11 0 E 101.67 1101.71 7l 1. F 67 101.74 G 101.67 101.76 H 101.67 101.74 1 101.67 101.62 K 101.67 101-63 TOP OF INFILTRATORS DESIGN ACTUAL DESIGN ACTUAL A 102.00 102.01 K 102.00 102.01 B 10100 101.97 L 102.00 102.05 C 102.00 101-98 IM 102.00 102.06 D 102.00 102.03 N 102.00 102.01 E 102.00 102.04 0 102.00 102.02 F 102.00 102.08 P 102.00 102.02 G 102.00 102.13 Q 102.00 102.02 H 102.00 102-10 R 102.00 102.02 1 102.00 102.03 S 102,00 102.03 102.00 101.99 T 102.00 102.01 BOTTOM OF BED 101.00 100-94 EXISTING )RIVEWAY SYSTEM TIES . ........ ........ 1 TO TANK IN 65.0' 2 TO TANK IN 32.5' 1 To TANK OUT 72.7: CORNER OF BULKHEAD 2 TO TANK OUT 31.6 ASSUMED DATUM) 1 TO PUMP IN 75.0' 2 TO PUMP IN 25.0' 1 TO PUMP OUT 77.1' 00 �c 2 TO PUMP OUT 18.7' s :P� 0 2 TO D-BOX 44.9' "3 3 TO D-BOX 47.1' C) 2 TO A 44.0' 2 TO K 91.6' 3 TO A 35.4' 3 TO K 73.8' ......!4. 2TOJ 55.1' 2 TO T 97.8' 1 w 3TOJ 622 3 TO T 90.11 BENJAMIN C, 03GCM,JL CML NO.49891 INSPECTION PORTS 2 TO X 76.3' 2 TO Y 83.5' 3TOX 60.01 3TOY 79.0' LOCUS MAP NOT TO SCALE 20' 0 20' 40' 60' AS-BUILT SEPTIC SYSTEM 857 CHESTNUT STREET NORTH ANDOVER,MA 43.55 Ic ASSESSORS MAP 107C LOT 27 25.00' Ur STREET SCALE: I"=20' JUNE 12,2007 NEW ENGLAND ENGINEERING SERVICES,INC. 1600 OSGOOD STREET z SITE BUILDING 20,SUITE 2-64 NORTH ANDOVER,MA 01845 PH:(978)686-1768 FAX:(978)327-6138 PLAN#: CH77KED 1254SAB-6-12-07 Dy�"S.G.B. I BY: B.C.O.Jr. THIS IS TO C SERVICES,It DISPOSAL S) NORTH AND( WITHIN ALLC 15.00,THE AF TO 12-12-06, HEREIN. N/F WESTPHALEN 40 MIL IMPERVIOUS BARRIER VENT- 17-29,40" N/F MURPHY 229 66' -32"111* TP 1 -29- T S R O P O N M L K PT I INSPECTION PORT(TYP.)- r I` LIMIT OF SAND TP 2- y x Y TP 06-1 PT 06-1 TP 06-2- I H G IF E D C B A 36, EXISTING IN GROUND POOL 10 OUTLET DISTRIBUTION BOX 3 GARAGE 20'--.. EXISTING PT 06-2 CABANA 8 ROWS OF 15 I 2 BENCHMARK:TC CHAMBER I /-FOUNDATION.E RESERVE AREA Ay (120 UNITS) (26.1r x 60-0') TP 06-3 1-1 TP 06-4 2"SCH.40 PVC I FORCE MAIN 82' -20'- - --------J 1000 GALLON EXISTING FOUR MONOLITHIC x OR 62'-- BEDROOM HOUSE PUMP CHAMBER 1 ST FLOOR ELEV.104.00 1500 GALLON MONOLITHIC pp SEPTIC TANK O O O 857 CHESTNUT STREET E,XISTING: ASSESSORS MAP 107C LOT 27 1 DRIVE.W I AY 45,005±SQ.FT 192.08, PRESSURE SW30,30,,w WATER SERVICE cl,pSTIVUT STREET