HomeMy WebLinkAboutCorrespondence - 50 ROCKY BROOK ROAD 9/10/1999 Town of North An over � psoRTH ,
OFFICE OF ��o<<<``° <,�o
COMMUNITY DEVELOPMENT AND SERVICES A
27 Charles Street "
North Andover, Massachusetts 01845
WILLIAM J. SCOTT 9SSACHUS�S
Director
(978)688-9531 Fax (978) 688-9542
September 10, 1999
Steven D'Urso
22 Lilly Pond Road
Boxford, MA 01921
Re: Lot 23B Rocky Brook Road
No. Andover, MA 01845
Dear Mr, D'Urso:
This is to inform you that the proposed septic system repair plans for the site referenced
above dated 9/1/99 have been approved for a house with a maximum of nine rooms.
If you have any questions, please do not hesitate to call the Board of Health Office at
978-688-9540.
Sincerely,
Sandra Starr, R.S.
Health Administrator
SS/Smc
cc: Dave Kindred
File
BOARD OF APPEALS 688-9541 BUILDING 688-9545 CONSERVATION 688-9530 HEALTH 688-9540 PLANNING 688-9535
Sep-08-99 02 : 37P Paul D. Tui-bide, PE/PLS 508-465-0313 P .02
September 8, 1999
Sandra Starr
North Andover Board of health Administrator
Office of Community Development and Services
30 School St.
North Andover, MA 01845
RE: Title V second review for Lot 23a Rocky Brook Road
Dear Sandra,
1 have reviewed the revised design plans for the above-mentioned project with revision
date of 9!1199. All the concerns outlined in my report dated August 11, 1999 have been
addressed except the following.
o My report requested that a 6" stone base be shown beneath the septic tank and
dbox. A 6" rg avel base is shown on the revised plans. The gravel base should be
changed to a stone base.
(If this minor revision is made 1 do not have to review the plans again.)
If you have any questions or comments please feel free to contact me.
Sincerely /
Carlton A4own, PE/PLS
Rockybrooklot23 a2.doc
ME
FURT
ENGINEERING
Civil Engineers&
Land Surveyors
One Harris Street
Newburyport,NIA
01950
(978)465-859.4
Town ®f North Andover f p�ORTH
OFFICE OF ��o�t t o do
COMMUNITY DEVELOPMENT AND SERVICES
27 Charles Street
North Andover, Massachusetts 01845 SgcH 00"
WILLIAM J. SCOTT
Director
(978)688-9531 Fax (978) 688-9542
August 11, 1999
Steven D'Urso
22 Lilly Pond Road
Boxford, MA 01921
RE: Lot 23A Rocky Brook Road
Dear Mr. D'Urso:
This letter is to inform you that the proposed septic plan for Lot 23A Rocky
Brook Road, North Andover has been disapproved for the following reasons:
1. Septic tank missing manhole to within 6" of final grade. (310 CMR 15.228(2))
2. Septic tank and d-box missing six-inch stone base. (310 CMR 15.221(2)).
3. Septic tank inlet tee does not extend minimum of 10" below flow line. (310 CMR
15.227(6)).
4. Septic tank outlet tank does not extend minimum of 14" below flow line. (310
CMR 15.227(6)).
S. Because of proximity to driveway,septic tank should be H-20.
6. Soil tests were performed more than two years ago. (NA 7.05)
7. Street number,map and lot number missing from plan. (310 CMR 220(4)(u)).
8. Names of abutters missing. (NA 8.02j)
9. Distances from tank, leaching area and reserve to property line missing. (NA
8.03b)
10. Limits of excavation around leach area missing. (NA 8.02z)
11. Toe of fill slope must stop 5'from the property line or a Swale must be installed.
(310 CIVIR 15.255(2)).
12. Both trench distribution lines must be connected to vent. (310 CMR 15.152(9)).
13. Leach area less than 4' above EST-1W adjusted for high point of existing grade.
(310 CNVIR 15.212). Highest,elevation 126 . ESHW 24" down. Thus elevation
under leach area should be 128'.
14. If leach area raised 1' to meet separation to groundwater,building sewer will be
above ground unless garage floor and driveway are raised.
15. Impervious barrier appears to be needed on easterly property line for slope or a
slope easement needs to be obtained and filed.
16. Final grading on south side of system not legible on plan.
BOARD OF APPEALS 688-9541 BUILDING 688-9545 CONSERVATION 688-9530 HEALTH 688-9540 PLANNING 688-9535
Please do not hesitate to call the Health Department at 978-688-9540 if you have any
questions.
Sincerely,
_,,,daALd,w
Sandra Starr,R.S.
Health Administrator
Cc: D. Kindred
H. Griffin
File
Town of North Andover 01 ORTtj I
OF,F ICE Of,
0
COMMUNITY DEVE LOPMENT AND SERVICES
146 Main Street X
4 o
North Andover, Massachusetts 01845
WILLIAM J. SCOTT IS SA U5
Director
January 6, 1997
Mr. Steve D'Urso
22 Lilly Pond Road
Boxford, NIA 01921
Re: Lot 23A Rocky Brook Road
Dear Steve:
This is to inform you that the proposed plans for the site referenced above have been
disapproved for the following reasons:
1. Benchmark within 75 feet of system missing. (3 10 CNIR 15.220(q))
2. Foundation drain missing. (N.A. 6.020)
3. Gas deflector/baffle missing from outlet tee of tank. (3 10 CNIR 15.227(4))
4. Add note: First 2 feet of pipe from D-Box to be level. (3 10 CN4R 15.232(c))
If you have any questions, please do not hesitate to call the Board of Health Office at the
number below.
Sincerely,
Sandra Starr, R.S.,
Health Administrator
SS/cjp
cc: Flintlock, Inc.
4r
BOARD OF APPEALS 688-9541 BUILDING 688-9545 CONSERVATION 688-9530 HEALTH 688-9540 PLANNING 688-9535
DATE / 7
Shcct of
BOARD OF HEALTH
TOWN OF NORTH ANDOVER
SUBSURFACE DISPOSAL DESIGN REVIEW
FEE PERMIT # DATE RECEIVEDU
APPLICANT - e" "�� , * , ASSESSOR' S MAP
PARCEL #
ADDRESSC� S. m , / P LOT # r
STREET #
ENGINEER
ADDRESS
PLAN DATE _ / ; REVISION DATE
CONDITIONS OF APPROVAL:
APPROVED
DISAPPROVED /
�."'d
,s. .- /M1,,( Fw'd d�d,...d/ .., q k °a'"' d .,✓' 4trro'7 d,./
d :>
.. ,,. ` ""
SEPTIC PLAN SUBMITTALS
LOCATION: ; ('S _ d C�Z}-° •�:,
NEW PLANS: YES $60.00/Plan
REVISED PLANS: YES $25.00/Plan
DATE: I �j
DESIGN ENGINEER:
When the submission is all in place, route to the Health Secretary
SEPTIC PLAN SUBMITTAL FORM
LOCATION:
NEW PLANS: YES $125.00lPlan
REVISED PLANS: CAS/ $ 60.00/Plan
SITE EVALUATION FORMS INCLUDED: YES FO
DATE:
DESIGN ENGINEER:
DATE TO CONSULTANT:
*If you want your plans expedited, please submit three plans and included a
stamped envelope with the correct amount of postage to mail plans to Port
Engineering.
When the submission is all in place, route to the Health Secretary.
SEPTIC PLAN SUBMITTAL FORM
LOCATION: G �6
NEW PLANS: YES $125.00/Plan
REVISED PLANS: YES $ 60.00/Plan
SITE EVALUAT ON ORMS INCLUDED: YES NO
DATE: � � � �
DESIGN ENGINEER: ��'�� )DO e
DATE TO CONSULTANT:
*If you want your plans expedited, please submit three plans and included a
stamped envelope with the correct amount of postage to mail plans to Port.
Engineering.
When the submission is all in place, route to the Health Secretary.
Town of North Andover, Massachusetts Fo►m No.a
of 40RT„9 BOARD OF HEALTH
F
p
DESIGN APPROVAL FOR
ssq�"°SE` SOIL ABSORPTION SEWAGE DISPOSAL SYSTEM
Applicant t Test No.
Site Location
Reference;Plans and Specs.
EN NEER DESIGN DATE
Permission is granted for an individual soil absorption sewage;disposal system to be installed
in accordance with regulations of Board of Health'.
CHAIRMAN,BOARD OF HEALTH
Fee Site System Permit No. �