HomeMy WebLinkAboutCertificate of Compliance - 2001 SALEM STREET 2/26/2013 •
r
PUBLIC HEALTH DEPARTMENT
Town of North Andover
Community Development Division
CER" TIFICATE OF
COMPLIANCE
02/26/2013
This is to certify that the individual subsurface disposal system received a
SATISFACTORY INSPECTION of the:
Complete Repair and Construction
On-Site Sewage Disposal System
: Tom Sawyer
At:
2001 Salem Street
Map 34 Lot 2
North Andover, MA 01845
The Issuance of this certificate shall not be construed as a guarantee that the system will function satisfactorily.
Michele Grant
Public Health Agent V�
1600 Osgood Street,North Andover,Massachusetts 01845
Phone 978.688.9540 Fax 978.688.8476 Web www.townofnorthandover.coni
PUBLIC H t11iOf MEET 1MVt4 O KU1X) r=R
(offlalunity Ylaxuol0t111Lw[hvisior� tR R�( t� Rat°kRi G.I P R
TOWN OF NORTH ANDOVER
SEPTIC DISPOSAL SYSTEM—INSTALLATION CERTIFICATION
The undersigned hereby certify that the Sewage Disposal System('4 nstructed;( )repaired;
(Print Name)
Located at:
Installa„ �Address)
� �
Was installed in conformance with the North Andover Board of Health approved plan,originally dated
and last revised on with a design flow of
gallons per day. The materials used were in conformance with those specified on the
approved plan;the system was installed in accordance with the provisions of 310.CMR 15.000,Title 5 and local
regulations,and the final grading agrees substantially with the approved plan.All work is accurately represented on
the As-built which has been submitted to the Board of Health.
Bottom of Bed Inspection Date:
p
n
Engineer Representative(Signature)
rL, I Lf r�L A
And—Print Final Construction Inspection Date:
Engineer Representative(Signature)
And—Print Name
Installer:� :`� (Signature) e3( �' ��t
�- Dates
—Print And Name
Enginer: V401114.. � 1 ,f/ (Signature) Date: 0 i/ c P
And—Print.Name
Osgood Street, North Andover, Massachusetts 0 1845
Phone 978.688.9540 Nix 978.688.8474 Web htt .{/www,.to nofnortItondoaer.roin
•
North Andover Health Department
Community Development Division
QNSITE WASTEWATER SYSTEM T U TI NOTES
LOCATION INFORMATION
ADDRESS: 2001 Salem Street MAP: 34 LOT: 2
INSTALLER: Tom Sawyer
DESIGNER: Merrimack Engineering Services
PLAN DATE: 3/26/12
REVISED DATE: 8/8/12
BOH APPROVAL DATE ON PLAN: 5/1/12
INSPECTIONS
TANK INSPECTION: 8/15/12
DATE OF BED BOTTOM INSPECTION:
DATE OF FINAL CONSTRUCTION INSPECTION:
DATE OF FINAL GRADE INSPECTION:
SITE CONDITIONS
❑ Contractor reports any changes to design plan
❑ Existing septic tank properly abandoned
❑ Internal plumbing all to one building sewer
❑ Topography not appreciably altered
Comments:
SEPTIC TANK
❑ Building sewer in continuous grade, on
compacted firm base
❑ Cleanouts per plan
X Bottom of tank hole has 6" stone base
Weep hole plugged
❑ 1500 gallon tank has been installed
loading
X Monolithic tank construction (tank 16' from
house)
❑ Water tightness of tank has been achieved by
❑ Inlet tee installed, centered under access port
❑ Outlet tee installed, centered under access port
(gas baffle/effluent filter)
❑ inch cover to within 6" of final grade
installed over one access port
❑ Hydraulic cement around inlet & outlet
Comments:
PUMP CHAMBER
❑ Bottom of tank hole has 6" stone base
❑ Weep hole plugged
❑ 1500 gallon Pump Chamber installed
❑ loading
❑ Monolithic tank construction
❑ Inlet tee installed, centered under access port
❑ Pump(s) installed on stable base
❑ Alarm float working
❑ Pump On/Off floats working
❑ Separate on/off floats
❑ Drain hole in pressure line
❑ cover at final grade installed over pump
access port
❑ Water tightness of tank has been achieved by
testing
❑ Hydraulic cement around inlet & outlet
Comments:
CONTROL PANEL
❑ Alarm & Pump are on separate circuits
❑ Alarm sounds when float is tripped
❑ Location of control panel: basement
❑ Alarm signal located inside: basement
Comments:
DISTRIBUTION-BOX
❑ Installed on stable stone base
❑ H-20 D-Box
❑ Inlet tee (if pumped or >0.08'/foot)
❑ Hydraulic cement around inlet & outlets
❑ Observed even distribution
❑ Speed levelers provided (not required)
Comments:
SOIL ABSORPTION SYSTEM (General)
X Bottom of SAS excavated down to C soil layer,
as provided on plan
X Size of SAS excavated as per plan 58x25'
❑ Title 5 sand installed, if specified on plan
❑ 40 Mil HDPE barrier installed
❑ Laterals installed and ends connected to
header (and vented if impervious material
above)
❑ Elevations of laterals and chambers installed as on
approved plan
❑ Retaining wall (boulder/ concrete /timber/ block)
❑ Final cover as per plan
Comments:
SOIL ABSORPTION SYSTEM (Gravel-less Chambers)
❑ Brand and Model of Chamber: Standard Quick
4 Infiltrator Chambers
❑ Number of chambers per row:
❑ Number of rows (trenches):
Comments: Total Chambers =
FINAL GRADE
x Loamed?
x Seeded?
❑ Cover per plan?
Comments:
DOCUMENTS NEEDED
Certification of Installation Form submitted
By engineer and signed and dated by
Engineer and installer
As-Built Plan
BM =
HR =
HI =
SYSTEM ELEVATIONS
ROD AS-BLT INVERT DESIGN INVERT
ELEVATION ELEV ELEV
Benchmark
Building Sewer OUT
Septic Tank IN
Septic Tank OUT
Pump Chamber IN
Pump Chamber OUT
Distribution Box IN
Distribution Box OUT
Lateral 1 TOP
Lateral 1 INVERT
Lateral 2 TOP
Lateral 2 INVERT
Lateral 3 TOP
Lateral 3 INVERT
Lateral 4 TOP
Lateral 4 INVERT
Lateral 5 TOP
Lateral 5 INVERT
Lateral 6 TOP
Lateral 6 INVERT
Top of Chamber
Bottom of Bed/Chamber
SKETCH PLAN
CRITICAL SETBACK DISTANCES
Mark those distances checked in the field against the design plan and regulatory
setback
Tank SAS Sewer
® Property line 10 10 --
® Cellar wall 10 20 --
® Inground pool 10 20 --
® Slab foundation 10 10 --
® Deck, on footings, etc 5 10 --
® Waterline 10 10 101
® Private drinking well 75 1002 50
® Irrigation well 75 100
® Surface Water 25 50
® Bordering Vegetated Wetland ,
Salt Marsh, Inland/Coastal Bank 75 100
® Wetlands bordering surface
water supply or trib. (in Watershed) 150 150
® Trib. to surface water supply 325 325
® Public well 400 400
® Interim Wellhead Prot. Area
® Reservoirs 400 400
® Drains (wat. supply/trib.) 50 100
® Drains (intercept g.w.) 25 50
® Drains (Other)Foundation 10(5) 20(10)
® Drywells 20 25
Suction line 222(2)
2 100 feet is a minimum acceptable distance and no variance is allowed for a lesser distance(NA 5.02).
3 As defined in 310 CMR 10.55, 10.32, 10.54,and 10.30,respectively,pursuant to 15.211(3),also by NA
wetland bylaws