Loading...
HomeMy WebLinkAboutCorrespondence - 835 CHESTNUT STREET 4/18/2003 MW Town of North Andover, Massachusetts Form No. 1 NORTH BOARD OF HEALTH 301 `EO 16 O y� l.. L 0 s= , ' APPLICATION FOR SITE TESTING/INSPECTION AO"ATE.PP93 .' ��SSACHU$ Applicant 14A1_1 , TELEPHONE NAME ADDRESS Site Location ' Engineer NAME ' gpDR SS TELEPHONE Test/Inspection Date and Time �� CHAIRMAN,BOARD OF HEALTH Fee Test No. S.S. Permit No.`�l/ D.W.C. No. C.C. Date Plbg. Permit No. I SIR Town of North Andover, Massachusetts F°"" N N°RTN BOARD OF HEALTH r° ° P DESIGN APPROVAL FOR ss^CHUStt SOIL ABSORPTION SEWAGE DISPOSAL SYSTEM A licant <_ Test No. Site Location ���' Reference Plans and Specs%`/-^ '� ENGINEER DESIGN DATE Permission is granted for an individual soil absorption sewage disposal system to be installed in accordance with regulations of Board of Health. 01-AIRMAN,BOARD OF HEALTH Fee 5r Site System Permit No. � � CHECKLIST FOR NORTH ANDOVER SEPTIC SYSTEM PLANS Job The following is a checklist that incorporates all Title 5 and local regulations for septic plans. Name of Applicant- :.--�l Cq r7 rtq Name of Designer: , Plan Date: {° Revision Date: Date of Review: Property Address: J ) /� ?' ��/ Map: Lot: BOH Reviewer: Type of Plan(new or upgrade):__ Number of Bedrooms in Assessor's Records: gpd)Garbage Disposal Allowed:A— General Information: N.A. =North Andover Septic Regulations Other numbers refer to Title 5 OK Problem N/A :> Street number and map/lot-220(4)(u) Maximum scale of 1 "=40'for plot plan-220(4) z' Maximum scale of I "=20'for profile and component details-220(4) Legal boundaries of the facility being served-220(4)(a) Names of abutters from recent tax map- NA 8.02j Number of bedrooms,design calcs., -NA 8.02i t`f Name&address of record owner&applicant- NA 8.02k -t- Name&address of designer-NA 8.021 Holder and location of all easements-220(4)(b) Date plan drawn&any revision date- NA 8.02m All dwellings and buildings,existing and proposed-220(4)(c) Location of all existing or proposed impervious areas-220(4)(d) All distances on site plan–NA 8.03a-c U° Elevation of proposed driveway-NA 8.02t Location and elevation of foundation drain-NA 8.02y t Location and dimensions of the system incl.reserve(new const.)-220(4)(e) '- Limits of excavation of leach area on site plan-NA 8.02z tr° Locus plan-220(4)(t) (Not to scale) — North arrow-220(4)(g) Existing and proposed contours-220(4)(g) _l Locations and logs of deep holes-220(4)(h) —�� Locations and logs of percolation tests-220(4)(i) Date(s)of soil testing-220(4)(h)&(i) Existing grade elevation of each deep hole-220(4)(h) Elevation of percolation tests–N.A. 8.02n Name of approving authority representative-220(4)(h)&(i) Name of soil evaluator-220(4)0) Soil logs and perc test logs match BOH records Locations of waterlines,drains, and subsurface utilities-220(4)(m) Observed and adjusted g.w. elevation in the vicinity of the system-220(4)(n) u Complete profile of the system to scale-220(4)(o),NA 8.02c .' Cross section of leaching facility-NA 8.02w (Not to scale) Location of benchmark(s)within 50-75 feet of facility-220(4)(q) Note listing all variance requests with proper citations-220(4)(p) ti. Local upgrade approval request form submitted-403(1) 2 Original R.S./P.E. stamp,signature&date-220(l) &(2) � P.E., discipline specified within stamp. MGL C. 112 s. 81M sfc. supplies(w/in 400'),pub. wells(w/in 250'),Pvt. wells(w/in 150')-220(4)( Location of watercourses, wetlands,wells,etc. w/in 150'of system—NA 8.02r ` Wetland disclaimer—NA 8.02s z RLS plan reference&certification required(prop line setbacks)-220(3) Plan contains designer's certification statement tom. Use approvals/standards checked for I/A system-DEP does., t. Pere rate>30 MPI-not allowed for new,LUA for upgrade-245(1)&('3) Perc rate > 60 MPI-must use modified tight tank or I/A technology-245(4) r-11 Proposed system qualifies as "shared" system-002(definitions) L--1 Flow is over 2,000 gpd-No R.S. allowed-220(1) Design flow was set in accordance with code-203 Existing system location and note on proper abandonment-354 Leaching facility at least 1' above Base Flood elevation—NA 9.05 All piping Sch 40 minimum—NA 10.01 Basement floor minimum 1' above groundwater elevation—NA 5.04 Foundation drain present with elevation—NA 8.02y On-site Soil and Groundwater Review OK Problem N/A Proper deep observation hole logs on plan-220(4)(h) All deep holes and peres shown,including aborted tests—NA 8.02n Soil evaluation forms submitted within 60 days of field work-018(2) / Proper percolation test log-220(4)(i) Ample deep observation holes in primary disposal area(minimum 2)- 102(2) Ample deep observation holes in secondary disposal area(minimum 2)- 102(2) i d Ample perc testing(one in each disposal area,3 in prim.>2,000 gpd)- 104(4) Deep hole testing conducted within two years—NA 7.05 Hole Identification Numbers: ground elevation el. 1(1� acceptable soil el. 16 12 Leach facility invert el. ✓jam A 7 l �x�� ground water el. lb / . refusal el. J`�' , 6) ?L bottom of leach facility el. �Z � thickness of acceptable soil /`/ � 6 before&after soil R&R 1 / � separation to groundwater separation to refusal /e -j— C soil class 2 3 perc rate (J J loading rate septic tank below g.w. table (yes or no) pump tank below g.w. table (yes or no) l.f in fill -255(t) Setback Distances(Given in feet) 15.21 1 YES NO Is the lot in the Lake Cochiewick Watershed? NA 6.00&5.02 OK Problem N/A Septic Tank Leach Facility Property line 10 10 Cellar wall 10 20 Inground pool 10 20 Slab foundation 10 10 z/ Deck,on footings,etc. 5 10 ✓`f Waterline 10 10 ' Private drinking well 75 100 Irrigation well 75 100 ,-Wetlands 75 100 Public well 400 400 Wetlands bordering surface 150 150 water Supply or trib. (in Watershed) Trib.To Surface Water supply 325 325 Reservoirs 400 400 l Tributaries to reservoirs 200 200 i� Drains(wat. supply/trib.) 50 100 Drains(intercept g.w.) 25 50 _ Foundation drains 10 20 Drains(Other) 5 10 Drywells 20 25 Downhill slope 15'to 3:1 slope 3 4 w/o barrier Building Sewer OK Problem N/A t� Grease trap required for certain uses(check 230 for details) r0 Pipe diameter listed(4" minimum)-222(1) LZ Pipe schedule listed-222(3) t Pipe cast iron or Sch 40 PVC—NA 11.02 Watertight joints specified -222(3)&(4) i Pipe laid on compact,fin base-222(5) Pipe laid on continuous grade in straight line-222(7)@ 117 Cleanouts precede all changes in alignment and grade-222(8) Cleanout provided every 100 feet-222(8) L Manhole at any 90 degree alignment change-222(8) Invert elevation at building: Invert elevation at septic tank: Length of run: Slope: (minimum of 0.01 -0.02 desired)-222(6) 10'offset to private well or suction line-222(2) Septic Tank OK Problem N/A Tank is accessible-228(3) No structures above tank-- (228(3) Tank can accommodate both primary&reserve—NA 9.04 —' 200%of flow(required&provided given. 1500 min.)-220(4)(f) &223)(1)(a) �✓ 2-3" drop from inlet to outlet-227(5) Minimum of 4'liquid depth-223(2) 3"air space above tees/baffles(minimum)-227(4) r 9"air space above flow line (minimum)-227(4) Tees are not to be replaced by baffles-227(1) Tees extend 6" above flow line-227(1) Inlet tee extends 10"below flow line(minimum)-227(6) Outlet tee extends 14" below flow line(more for deeper tanks)-227(6) Gas baffle installed on outlet-227(4) Access manhole cover above center of tank&each tee(except 2 compart) 228(2) 3-20" manholes-228(2) 1 childproof,24" riser/manhole w/in 6"of final grade if<1000gpd-228(2) Inlet and outlet tees on center line-227(1) Soil compaction below tank specified(if soil is non-native)-221(2) 6" of<=3/4"stone beneath tank specified-221(2)&22 8(1) v If> 1,000 gpd AND not a single fam. dwell.must be 2 tks or 2 comp. -223(1)(b) If plan specifies disposal must be 2 tanks in series or 2 compart. tank-223(l)(c) Buoyancy calcs.required if tank at or below water table-221(8) Tank is watertight-221 (1) 9" of cover over tank(minimum)-228(1) r/ H- 1 0 loading(min.) H-20 if4affic-226(3) Top of tank<=36" below grade-221(7) All pumping to tank(if applies)in accordance with-229 Tank is set to keep old system in service during install if possible 4 5 Tight Tank(Check here if not present: ) OK Problem N/A 500%of design flow or 2000 gallons provided—260(2)(a) 3-20"manholes—228(2) Soil compaction below tank specified(if soil non-native)—221(2) 6"of<=3/4"stone beneath tank specified—221(2) &228(1) Buoyancy cales. Required if tank at or below water table—221(8) Tank is watertight—221(1) 9"of cover over tank specified(minimum)—228(1) H-10 loading(min.)—H-20 if traffic—226(3) Top of tank<=36"below grade—221(7) All pumping to tank(if applies)in accordance with—229 A/V alarm set at 3/5 tank capacity—260(2)(c) Min. 1-24"frame w/cover at finished grade—228(2)(f) Year round access for pumping—228(2)(g) Distribution Box(Check here if not present: ) OK,/ Problem N/A Inlet elevation: <�'d Outlet elevation: 0.17'drop from inlet to outlet(minimum)-232(3)(b) 6" sump(minimum)-232(3)(e) All outlets at same elevation-232(3)(b) Outlet pipes laid level for first 2 ft.-232(3)(c) Pipe Sch 40-NA 10.01. Number of outlets: Number of laterals: Size of outlets: c/- ' " Inlet.baffle/tee min. 1" over outlet invert,for all d-boxes-232(3)(a), Soil compaction below distribution box specified(if soil is non-native)-221(2) 6" of stone beneath distribution box specified-221(2) Box is watertight-221 (1) Top of box<=36" below grade-221(7) d% Buoyancy calculations required if box is at or below water table-221(8) Pump Chamber(Check here if not present: ) OK,.; Problem N/A Volume specified: _100e),Q 220(4)(r) Pump on elevation- j. 220(4)(r) / Pump off elevation:} 220(4)(r) r Alarm on elevation: 220(4)(r) L Number of cycles per day-220(4)(r)(also 254(1)(d)if gravity from d-box) Minimum 2" delivery line to d-box if gravity-254(1)(c) ✓ Pressure dosed l.f. if flow>=2,000 gpd-254(1)(a)&254(2)(a) Cycles per day is consistent with chamber volume-23 1 i Volume calculations include flowback volume-2') 1(2) 5 6 24 hour storage capacity,above pump on elevation-231(2) Number of pumps:� 2 if system serves>2 dwelling units-231(6) - Capacity of pump(s)- gpm @ ;�e'_3 'TDH-220(4)(r) Pump can pass 1 1/4 "solids(minimum)-231(7) Pump controls specified-220(4)(r) Alarm equipment specified-231(2) Alarm is in building and powered on separate circuit from pump-2') 1(9) Pump sequence correct(off-lead on-lag on-alan-n on)-231(8) Pump performance curves included-220(4)(r) Manual operating switch-NA 12.01 Check valve,bleeder hole-NA 12.01 v` 1 childproof,24"riser/manhole to final grade-2'31(5), LX, Soil compaction beneath pump chamber specified(if soil is non-native)-221(2) 6"of<=3/4"stone beneath chmbr. specified-221(2)&228(1), t Buoyancy calculations if chamber is at or below water table-221(8)@ 9" of cover over cha er( 'nimum)-228(1) H- 10 loading(min.)LL-U-20 ' f traffic-226(')), Chamber is watertight-221 (1) ' Top of chamber<=36" below grade-221(7) Leaching Facility(general-complete for all designs) OK Problem N/A�;. 50% larger if garbage disposal-240(4) Trenches to be used whenever possible-240(6) No vehicle or imperv. area above l.f.unless unavoidable-240(7);NA 13.02 t! Vented if under impervious cover-241 (1) Vented through same pipes as distribution system-241 (1)(a) Vent protected from precipitation/animal entry-241 (1)(b) '. Vent is placed beyond traffic or impervious area-24 1 (1)(c) tl All lines connected to vent if bed or trenches-241(1)(d) t z 9" cover over peastone-240(9) Reserve area provided(new construction)-248(1) Reserve 4' from primary leach area—NA 9.04 1 4'(5'if perc rate<=2 MPI)separation to g.w. -212(a)&(b) ` 4'(down to 2'with variance or I/A-upgrades only)of natural soil under l.f. GW separation is adjusted to highest existing grade if facility cuts into a hillside Pipe slope minimum of 0.005 -251(9) �. Require 5'removal and replacement if in fill-255(5) ✓ Top of leach facility<=36" below grade-221(7) Final grade over l.f. minimum 0.02 ft/ft-240(1 0) �- Surface&subsurface drainage away from L£-240(1 1) &245(5) Minimum design flow 440 gpd without deed restriction—NA 13.01 f 3:1 slope where grading required-255(2) Toe of fill slope stops 5'from property line or Swale installed-255(2) Impermeable barrier if<3:1 slope or< 15 feet to—3:I slope-255(2) t!.. Impermeable barrier/retaining wall poured concrete—NA 9.02 Retaining wall stamped by P.E. -255(2)(b) Top of retaining wall>=top of peastone elevation-255(2)(f) r_ . 10'offset from edge of leach facility to edge of ret. wall -255(2)(g) k_"' Pere test(s)done in most restrictive layer- 104(2) r Pere test 4' below leaching elevation—NA 7.06 Design flow listed and required/provided leach area given-220(4)(f) Leach pipes SCH40 PVC—NA 10.01 t� Leach pipes minimum 4" diameter except for dosed system—NA 14.04 6 7 Leach lines capped, vented,or connected together-251(9) Pressure dosing guidance followed if pressure distribution-254(2)(c), Pressure dosing required over 2,000 gpd or with I/A remedial use-231(1) Leaching Trenches(Check here if not present: ) OK Problem N/A Number of trenches: Minimum of 2 trenches-NA 9.01(2) Depth of trenches(max eff. 2'): -247(l) Width of trenches(Train.,Truax.): -251 (1)(b) Length of trenches(100'max.): -25 1 (1)(a) Trenches are vented(when>50')-251 (11) Trenches follow contour lines-251(2) Trench spacing 3 times effective width or depth minimum-251 (1)(d) In fill or reserve between trenches, 10' min. -NA 14.01& 14.03 Available leach area given (Min. 500 s.f.)-NA 9.01(2) Bottom=L x W x# = s.f. Sidewall=L x D x# x 2= s. f. Effective leach area given Loading factor: Effective area=total area s.f. x LTAR = g/day Effective area is>=design flow of facility being served 2"of 1/8"- 1/2" 2x washed peastone.-247(2) Trench depth of 3/4" to 1 1/2" double washed stone-247(1) Leaching Pits(Check here if not present: -- ) OK Problem N/A #of pits/pit systems: (dosing chamber if>1,231 (1)) Dimensions of each pit or system:L W D Depth of pits(max eff. 2'): -253(1)(a) Available leach area given Bottom=L x W x#of systems= s.f. Sidewall=L+W x D x 2 x#of systems= s.f. Total area=bottom +sidewall — s.f. Effective leach area given Loading factor: Effective area=total area s.f. x LTAR =—g/day Effective area is>=design flow of facility being served Minimum of 2 pits at least 13'X16'—NA 9.01(3) Distribution for galleries/chmbrs. in trench config. -pipe every 20'-253(6) Distribution for galleries/chmbrs. in bed config.-ea.pipe serves<=40 s.f.-253(6) Spacing-2 times the effective width or depth(the greater)-253(1)(c) 2"of 1/8"- 1 /2" 2x washed peastone.-247(2) 3/4" to 1 1/2" double washed stone-247(1) Each pit has at least one 20" access cover. 24" CI to grade over 2,000 gpd -253(3) Surrounding aggregate thickness between P(min.)and 4'(max.)-253(1)(b) Vents,if necessary,extend under covers of pit(s)-241 (e) Leach Fields(Check here if not present: ) OK Problem N/A Number of fields: l (need dosing chamber if> 1,231 (1)) 7 8 Length(100'max.): -252(2)(b) Width: / Total area: L �•__ , x W Minimum 900 square feet-NA 9.01(1) r� Distribution lines connected with solid pipe—NA 15.01 Effective leach area given Loading factor: _ 1~ Effective area=total area s.f x LTAR g/dav Effective area is>=design flow of facility being served Minimum of two distribution lines-252(2)(a) y . Cline separation(max.)-252(2)(d) Z / 4'maximum separation from edge of field to line-252(2)(e) 10'minimum separation between adjacent leach fields-252(2)(f) Between 6" and 12" of 3/4 - 1 1/2" stone beneath field-252(2)(g)&247(2) 1 2"of 1/8"-1/2" 2x washed peastone.-247(2) Final Grading OK Problem N/A Slope over leach area minimum of 0.02 feet/foot—240(10) it Grading shall divert drainage away from leach area—240(l 1) Grading slopes away from dwelling 5/24/01 8 i / � � / � '� ��► _ __�� ���� � � .�� � �'� �� � ��r!r _� ''�___ I ' ��� +' ���� �� � .� ��s � ���� ��'���4�� �' �� ��� ���� ���� ���� NEW E III G W) ENGINEERING SERVICES .._......W —.... ..................��....................�...................................... ..,...........................o.o........ February 11; 2003 Sandra Starr, Administrator North Andover Health Department Town Hall Annex 27 Charles Street North Andover, MA 01845 � Re; 835 Chestnut Street,North Andover, Septic system design Dear Sandra: Enclosed are the following documents for the above referenced property. 1. S copies of°septic system design plans, one with an original stamp. 2. Application for approval and required fee. 3. Copy of soil evaluator sheets. This plan is being submitted for approval. If you have any questions regarding the information submitted, please do not hesitate to contact this office. Sincerely, ) BerijamuC. Osgoo r.,E1T President 60 C3N:ECHVVC)OD DRIVE- - NORTH ANDOVER, MA 01845-(9.78)686-1768-(888):189-7645-FAX(978)685-10799 SEPTIC PLAN SUBMITTALS Map LOCATION: "> <��':� �,.`�,�,��..�_�� , .�,,� ��r.`�� Ma & Parcel ,.5 NEW PLANS: ( YES) $225.00/Plan Check#: REVISED PLANS: YES $ 60.00/Plan Check#: SITE EVALUATION FORMS INCLUDED: rYES NO LOCAL UPGRADE FORM INCLUDED: YES NO DATE: °"' s� " DATE TO CONSULTANT: DESIGN ENGINEER< � ' " Telephone#: When the submission is complete (including check), date stamp plans, COPY for Conservation, and place in existing file with green Design Approval form. �f r ro f/ rf April 1, 2003 Ben Osgood, Jr. New England Engineering Services, Inc. 60 Beechwood Drive North Andover, MA 01845 Re: 835 Chestnut Street Dear Mr. Osgood: This is to notify you that the proposed plans dated February 6, 2003 for the repair of the septic system at 835 Chestnut Street, North Andover have technical deficiencies which must be addressed before the plans can be approved. They are: • The existing system location is missing. • The emergency storage capacity appears to be less than 24-hours. • Vent is missing devices to protect from animals, weather, etc. If you have any questions, please call the office at 978-688-9540. Sincerely, Sandra Starr,R.S., C.H.O. Public Health Director Cc: BOH Homeowner File �.� .o. NEW ENGLAND ENGINEERING SERVICES April 7, 2003 Sandra Starr, Administrator North Andover Health Department Town Hall Annex 27 Charles Street North Andover, MA 01845 Ike: 835 Chestnut Street,North Andover, Septic system design '' `�``� �""`` "�� Dear Sandra: Enclosed are 5 copies of revised septic system design plans, one with an original stamp for the above referenced property. The following corrections were made to the plan. 1. The vent detail has been revised to indicate the installation of a charcoal filter/animal screen. 2. The existing system locations have been added.. 3. A thrust block detail and a note indicating that thrust blocks shall be installed at all force main bends has been added. This plan is being submitted for approval. If you have any questions regarding the information submitted, please do not hesitate to contact this office. Sincerely, Benjamin C. Os ood, Jr.,EIT President Cc Owner 60 BEEC'I WOOD DRIVE NORTH ANDOVER, A 01845-(978)686-1768-(E,86)359-7645,. FAX(978)685--1099 INSPECTION CHECKLIST FOR SEPTIC SYSTEMS Yes NO Initials A. Bottom of Bed 1. Excavation to proper depth d '" 2. With trenches,sides of excavation are beneath B horizon - 3. Edge of excavation specified distance from foundation,etc. Comments: A p\j t B. Retaining Wall 1. Wall height and width as specified 2. Waterproofed 3. Wall minimum 10' to leaching facility 4. Wall meets specifications of plan Comments: C. Building Sewer 1. Pipe diameter minimum 4" 2. Schedule 40 pipe 3. Watertight joints 4. Inlet to tank cemented 5. Slope minimum 0.01 or 1/8"per foot minimum 6. Pipe properly set on compact firm base - 7. Pipe laid on continuous grade in straight line 8. Cleanouts precede all change in alignment and grade 9. Manholes at any 90°change 10. 10' minimum offset to water line Comments: D. Septic Tank 1. Level , 2. 1,500 gal minimum 3. Gas baffle present on outlet 4. Manhole to grade 5. Manholes over center and each tee _ 6. 3-20"manholes 7. Inlet tee minimum 12"under invert 8. Outlet tee minimum 14"under invert 9. Outlet line cemented , 10. Air space 3"above tees 11. 2"-3"drop from inlet to outlet 12. Pipe set 13. Compact base with 6"of'/4"crushed stone under tank 14. Tank is watertight Comments: Yes NO E. Pump Chamber 1. If separate from tank,compact base with 6"of'/4"stone underneath 2. Minimum 2"pipe to d-box if g }stern 3. 20"access manhole „1 4. Tank level - �-- 5. Watertight / 6. Tank size agrees with plan specification 7. Manhole to grade 8. Check valve and bleeder hole present 9. Alarm in building on separate circuit E 10. Alarm functions 11. Manual operating switch 12. Pump delivers liquid to d-box Comments: F. Distribution Box 1. D-box level 10 2. Minimum 0.1T'(2")drop from inlet to outlet 3. Minimum 6"sump 4. Outlet pipes show equal distribution 5. Compact base with 6"of stone beneath box 6. Box is watertight 7. All lines cemented with hydraulic cement 8. Schedule 40 pipe Comments: G. Soil Absorption system i. All stone double-washed-'/4"= 1 %" -pea stone Bucket test done? 2. Minimum 2"of pea stone above distribution lines 3. Minimum 6"stone beneath pipe 4. Distribution lines capped or connected together 5. Grading meets 3:1 slope 6. Minimum of 9"of fill graded over system G/- 7. Toe of slope stops minimum 5' from edge of property;if not,then Swale Comments: H. Leach Trenches 1. Minimum 2 trenches 2. Length of trenches agree with plan. (Max. length 100') 3. Width of trenches agree with plan-Minimum 2';maximum-4'. 4. Vent present if<50 feet or specified 5. Distance between trenches minimum 4'and maximum of 6' 6. Minimum distance between trenches 10' 7. Pipe slope minimum 0.005 or 6"per 100' 8. Depth of trenches below outlet invert minimum of 6 Yes NO 9. Pipes set on stable base. Comments: I. Leach Field 1. Maximum length of field 100' 2. Pipe slope minimum 0.005 or 6"per 100' 3. Separation between pipe 6'maximum 4. Pipes connected at end V 5. Separation between adjacent fields 10' minimum 6. Pipes set on stable base 7. Maximum 4' separation from edge of field to first line 8. Minimum two distribution lines 9. Maximum perc rate 20 mpi / Comments: I Leaching Pits 1. Minimum inlet pipe 4" 2. Pits of concrete 3. Sidewall between 12"and 48"wide 4. Access manholes on each pit 5. Pipes cemented with hydraulic cement Comments: K. Final Grade 1. Slope over soil absorption system minimum 0.02 _ 2. All system components covered by at least 9"soil 3. Cover soil free of stones larger than 6" 4. Grading slopes away from dwelling 5. No areas over system that may pond U v poi x Ch C7 rro �° ch N, C/a x — - _— C) a� G y cli qqk to a — - 0 o .. O o (^� k✓k uj CD Q C? rt G ro rro w b d x con mo y �' o Pr pw CD Pd 0 o W o ° a e� C v y cro CD a° ° ow a c 77 p tv ha a � � G 6 O ry rp O (D f7 5 00 b � w O to w ti yr o ' fA ��R 4pa b � a � o cz CIO ,_, kJ