Loading...
HomeMy WebLinkAboutCorrespondence - 223 FOREST STREET 6/10/1999 f.. NEW ENC") www :: LAND ENGINEERING... .._ _._ ...�_�. .... ....__ ..m._. ....� INC ..... . June 10, 1999 Sandra Starr, Administrator North Andover Health Department Town Hall Annex 27 Charles Street North Andover, MA 01845 Re: 223 Forest Street septic system design Dear Sandra: Enclosed are the following documents regarding the application for approval of the septic system repair for the above referenced property. 1. 5 copies of design plans. 2. Soil evaluator sheets 3. Check to cover the fee. If you have any questions or need additional information please do not hesitate to contact this office. Sincerely, Benjamin C. Osgood, Jr., EIT President 3 VVA9 KER ROAD-surr - N RTH ANDOVEFZ, A 0184�"_a ( ,. /8)¢at36..'f'768..(88f3)359w.I45..FAX(978)685-1099 May-27-99 12 : 45P (North Andover Com. Dev . 508 688 9542 P . 01 i SEPTIC PLAN SU-13MITTAL FORM LOCATION:-2,Z NEW PLANS: YIDS $125,00/1"Jan REVISED PLANS: YES S 60.00/Plan---------- SITE EVALUATION FORMS INCIJJDED: VES ) NO DATE:- 6- DESIGN ENGINEER: '.Jc. DATE TO CONSULTANT:-- *If you want your plans expedited, please submit three plans and included a stamped envelope with the correct amount of postage to mail plans to Port Engineering. M When the submission is all in place, route to the Health Secretary. ............ 'o Jun-17-99 10e10A Paul D- Tui-bide, PE/PLS 508-465-0313 P.04 June 17, 1999 Sandra Starr North Andover Board of Health Administrator Office of Community Development and Services 30 School St, North Andover, MA 01845 RE: Title V review for 223 Forest Street Dear Sandra, I find that the design plans adequately address Title V and local regulations. Various local upgrade approvals and local variance requests are noted. In my professional opinion the requests seem reasonable for the conditions of the lot. (One comment is that this is an existing 3 bedroom dwelling,but the design calculations as to size of leaching bed are based on a 4 bedroom dwelling. The review of this design was treated as an upgrade of a failed system for a 3 bedroom house. if an additional bedroom is added in the fixture(to make a total of 4 bedrooms) the system will have to be brought to"new construction" standards. (One area where it does not meet new construction standards is that there is no reserve.)) If you have any questions or comments please feel free to contact me. Sincerely Carlton A. Brown,PEIPLS Forest223.doc rum PORT ENGINEERING Civil Engineers& Land Surveyors One Harris Street Newburyport,iltA 0}950 (978)465-8594 'own of North Andover * NoWTH OFFICE OF 3� e`t ° ° O L COMMUNITY DEVELOPMENT AND SERVICES ° 27 Charles Street 1 North Andover, Massachusetts 01845 �9SSncHUS�s�y WILLIAM J. SCOTT Director (978)688-9531 Fax(978)688-9542 July 20, 1999 Ben Osgood, Jr. New England Engineering 33 Walker Road, Suite 23 No. Andover, MA 01845 Re: 223 Forest Street Dear Ben: This is to inform you that the proposed septic repair system plans for the site referenced above have been approved. If you have any questions, please do not hesitate to call the Board of Health Office at 978-688-9540. Sincerely, Sandra Starr,R.S. Health Administrator SS/smc cc: Guggenberger File BOARD OF APPEALS 688-9541 BUILDING 688-9545 CONSERVATION 688-9530 HEALTH 688-9540 PLANNING 688-9535 \.t _ .. w... _... ..._..W �._.._..... _ ...... ...... _._........_m...._................._. _.......... ._.._.M _... ... _. ... _.----------- NEW EINGLAND EINAGINE" de EIRING SERVICES __.......... _.w_ ._.µ.. _..__..._ .... ._ . ........... _mm.... ._.m......_. ......._..__ h N C _... _. _.... w. .._ .. _ _. .. ....�W .. August 8, 2000 Sandra Starr, Administrator North Andover Health Department Town Hall Annex 27 Charles Street North Andover, MA 01845 Re: 223 Forest Street,North Andover, Septic system design Dear Sandra: Enclosed are three copies of the as built plan and the certification for 233 Forest Street. The certification form needs the permit number and date added and it needs to be signed by Mike Reilly. If you have any questions please do not hesitate to contact this office. Sincerely, Benjan C. Osgood, r., EIT President 60 BEECI°9WOOD DRIVE.-NO RTH ANDOVER, MA 01845-(976)686-176€3-(866):359-7645-FAX(976)685.1099 INSPECTION CHECKLIST FOR SEPTIC SYSTEMS Yes NO A. Bottom of Bed 1. Excavation to proper depth's. �. 2. With trenches,sides of excavation are beneath B horizon ! �` 3. Edge of excavation specified distance from foundation,etc. Comments: B. Retaining Wall 1. Wall height and width as specified 2. Waterproofed 3. Wall minimum 10'to leaching facility 7/ 4. Wall meets specifications of plan Comments: C. Building Sewer 1. Pipe diameter minimum 4" 2. Schedule 40 pipe 3. Watertight joints 4. Inlet to tank cemented 5. Slope minimum 0.01 or 1/8"per foot minimum 6. Pipe properly set on compact firm base 7. Pipe laid on continuous grade in straight line 8. Cleanouts precede all change in alignment and grade 9. Manholes at any 90°change 10. 10' minimum offset to water line Comments: D. Septic Tank 1. Level 2. 1,500 gal minimum 3. Gas baffle present on outlet 4. Manhole to grade 5. Manholes over center and each tee ✓ . 6. 3-20"manholes 7. Inlet tee minimum 12"under invert kl/ 8. Outlet tee minimum 14"under invert ✓" 9. Outlet line cemented ✓ 10. Air space 3"above tees 11. 2"-3"drop from inlet to outlet 12. Pipe set 13. Compact base with 6"of/a"crushed stone under tank 14. Tank is watertight Comments: ' Yes NO E. Pump Chamber ., 1. If separate from tank,compact base with 6"of'/4"stone underneath 2. Minimum 2"pipe to d-box 1f.gravity system 3. 20"access manhole ` \ 4. Tank level 5. Watertight 6. Tank size agrees with plan specification ~\ 7. Manhole to grade 8. Check valve and bleeder hole present 9. Alarm in building on separate circuit 10. Alarm functions 11. Manual operating switch 12. Pump delivers liquid to d-box Comments: F. Distribution Box 1. D-box level 2. Minimum 0.1T'(2")drop from inlet to outlet 3. Minimum 6"sump 4. Outlet pipes show equal distribution 5. Compact base with 6"of stone beneath box ✓ 6. Box is watertight 7. All lines cemented with hydraulic cement 8. Schedule 40 pipe LZ Comments: G. Soil Absorption system 1. All stone double-washed-'/4 1 ''/z" -pea stone Bucket test done? .� 2. Minimum 2".of pea stone above distribution lines L✓ 3. Minimum 6"stone beneath pipe _ 4. Distribution lines capped or connected together 5. Grading meets 3:1 slope 6. Minimum of 9"of fill graded over system 7. Toe of slope stops minimum 5' from edge of property; if not,then swale. Comments: H. Leach Trenches � ��y 1. Minimum 2 trenches 2. Length of trenches agree with plan. (Max. length 100') 3. Width of trenches agree with plan-Minimum 2';maximum-4'. 4. Vent present if<50 feet or specified 5. Distance between trenches minimum 4' and maximum of 6' 6. Minimum distance between trenches 10' 7. Pipe slope minimum 0.005 or 6"per 100' 8. Depth of trenches below outlet invert minimum of 6". Yes NO 9. Pipes set on stable base. Comments: 1. Leach Field 1. Maximum length of field 100' 2. Pipe slope minimum 0.005 or 6"per 100' 3. Separation between pipe 6'maximum . 4. Pipes connected at end 5. Separation between adjacent fields 10'minimum 6. Pipes set on stable base 7. Maximum 4' separation from edge of field to first line 8. Minimum two distribution lines 9. Maximum perc rate 20 mpi Comments: J. Leaching Pits 1. Minimum inlet pipe 4" 2. Pits of concrete 3. Sidewall between 12"and 48"wide 4. Access manholes on each pit 5. Pipes cemented with hydraulic cement Comments: K. Final Grade 1. Slope over soil absorption system minimum 0.02 2. All system components covered by at least 9"soil 3. Cover soil free of stones larger than 6" 4. Grading slopes away from dwelling 5. No areas over system that may pond Town of North Andover, Massachusetts Form X0.2 BOARD OF HEALTH pORTF1 O P 1- F DESIGN APPROVAL FOR 'SSwC USE�h SOIL ABSORPTION SEWAGE DISPOSAL SYSTEM , Applicant Test N o Site Location r Reference Plans and Specs. WEER DESIGN DATE Permission is granted for an individual soil absorption sewage disposal system to be installed in accordance with regulations of Board of Health. CH RMAN,BOARD OF;HEAITH Fee �4;" 6 Site System Permit No. Fee-1 mg