Loading...
HomeMy WebLinkAboutCertificate of Compliance - 14 PURITAN AVENUE 4/15/2016 e ° 0 PUBLIC HEALTH DEPARTMENT Town of North Andover COMmunity Development Division CERTIFICATE OF COMPLIANCE As Of. 4/15/16 This is to certify that the individual subsurface disposal system received a SATISFACTORY INSPECTION of the: Repair of D-Box By Todd Bateson 14 Puritan Ave. Map 107B Lot 0133 North Andover, MA 01845 The,Issuance of this certificate shall not be construed as a guarantee that the system will function satisfactorily. 4 F f Michele Grant Public health Agent 1600 Osgood Street,North Andover,Massachusetts 01845 Phone 978.688.9540 Fax 978.688.8476 Web www.townofnortliandover.coni 0 ° 0 North Andover Health Department Community and Economic Development Division QNSITE WASTEWATER Y T UCTI NOTES LOCATION INFORMATION ADDRESS: 14 Puritan MAP: 107B LOT: 0133 INSTALLER: Todd Bateson DESIGNER: PLAN DATE: BOH APPROVAL DATE ON PLAN: INSP'ECT'IONS TANK INSPECTION: D-box 4/15/16 DATE OF BED BOTTOM INSPECTION: DATE OF FINAL CONSTRUCTION INSPECTION: DATE OF FINAL GRADE INSPECTION: SITE CONDITIONS ❑ Contractor reports any changes to design plan ❑ Existing septic tank properly abandoned ❑ Internal plumbing all to one building sewer ❑ Topography not appreciably altered Comments: SEPTIC TANK ❑ Building sewer in continuous grade, on compacted firm base ❑ Cleanouts per plan ❑ Bottom of tank hole has 6" stone base ❑ Weep hole plugged ❑ 1500 gallon tank has been installed H-10 loading ❑ Monolithic tank construction ❑ Water tightness of tank has been achieved by visual testing ❑ Inlet tee installed, centered under access port ❑ Outlet tee installed, centered under access port (gas baffle/effluent filter) ❑ inch cover to within 6" of finish grade installed over one access port ❑ Hydraulic cement around inlet & outlet Comments: PUMP CHAMBER ❑ Bottom of tank hole has 6" stone base ❑ Weep hole plugged ❑ 1500 gallon Pump Chamber installed ❑ H-10 loading ❑ Monolithic tank construction ❑ Inlet tee installed, centered under access port ❑ Pump(s) installed on stable base ❑ Alarm float working ❑ Pump On/Off floats working ❑ Separate on/off floats ❑ Drain hole in pressure line ❑ cover at final grade installed over pump access port ❑ Water tightness of tank has been achieved by testing ❑ Hydraulic cement around inlet & outlet Comments: CONTROL PANEL ❑ Alarm & Pump are on separate circuits ❑ Alarm sounds when float is tripped ❑ Location of control panel: basement ❑ Alarm signal located inside: basement Comments: DISTRIBUTION-BOX X Installed on stable stone base X H-20 D-Box ❑ Inlet tee (if pumped or >0.08'/foot) X Hydraulic cement around inlet & outlets X Observed even distribution X Speed levelers provided (not required) X Schedule 40 PVC Pipe Comments: