HomeMy WebLinkAboutCertificate of Compliance - 141 STONECLEAVE ROAD 6/13/2005 Town of Nortli Andover
Office of the Flealth Department
Coniniunity, Developinentand Services Division
400 OSGOOD STREET
Susan Y. Sawyer, REHS/RS 978.688,9540-Phone
Pa;rLl icy l:-le alt .. Director 978.688,8476 - Fax
leNIV
CERVq7ICAq'tE uw C0914TLIANCE
S
Furze 13, 2005"
This is to certify that
the individuafsu6surface disposal system
Repair (X.X)' by
2sodd Batesou
At
141 Stonec°Ceave Road
,?VorthAndover, ,4 01845
Ylas been installed in accordance with the provisions of Titfe v of the State Sanitary Code and
with the Worth Andover Board of.Ifealth regulations.
The Issuance of this cent f'cate shall not 6e construed as a guarantee that the system will
function satisfactorily.
Susan T Sawyer, REYfS19U
Tu6fic Yfeafth Director
130ARDOFANIFALS688-954 @3d.1lLIAN6688-954.5 H Al;' 11688.954(1 PLANNdNGW98-953>
AS-BUILT C HE CKLIST
LOT NUMBER, STREET NAME 0
ASSESSORS MAP& PARCEL NUMBER 1 2005
LOT LINES & LOCATION OF DWELLINGS e ° DEFIARI
LOCATIONS & DIMENSIONS OF SYSTEM,.
I tiled.
TIES.TO LOT LINES & DWELLING, WELLS
a. FROM SEPTIC TANK
b. FROM LFAC14 AREA
LOCATIONS OF DEEP HOLES& PERC
TESTS
ELEVATIONS OF DISPOSAL SYSTEM
TOP OF FDN ELEVATION
AIA LOCATIONS OF WELLS, DRAINS, WATERCOURSES
WITHIN I SO' OF SYSTEM
LOCATION OF WATER, GAS, ELECTRIC LINES, CABLE
DISTANCES FROM CORNERS OF HOUSE TO CENTER OF
TANK&D-ROTC
ORIGINAL STAMP & SIGNATURE
✓ IMPERVIOUS AREAS - DRIVEWAYS, ETC.
NORTH ARROW
"�� LOCATION& ELEVATIONS OF BENCHMARK USED
TOWN OF NORTH ANDOVER SEWAGE DISPOSAL SYSTEM
INSTALLATION CERTIFICATION
The dersigned hereby certify that the Sewage Disposal System ( ) constructed;
( repaired:
by -To ne
located at '0�'o N rU_J!�;k y i; YLv4 P
was installed in conformance with the North Andover Board of Health approved plan,
System Design Permit# dated ' with an approved design
flow of 440 gallons per day. The materials used were in conformance with those
specified on the approved plan; the system was installed in accordance with the provisions
of 310 CMR 15,000, Title 5 and local regulations, and the final grading agrees
substantially with the approved plan. All work is accurately represented on the As-built
which has been submitted to the Board of Health.
Bed inspection date:
Engineer Representative
Final inspection date: 5"/?-0 2
Engineer Repre entative
Installer: Lie.#: Date:
Design Engineer: Date:
TOWN OFNORTIJ ANDOVER
Offi ce of(--,0MN4LJNYl'Y DEVELOPMEN'r AND SERVICES
11EA1.31-1 DEPARI'MEW
27 CHARLES STR EL"T
NORTTI ANI)OVER, MAS` AC IC.S1."T'I'S 0 1845
Susan Y, Sawyer, RE[IS/RS 978M8.9540 Phone
Public 11calth Director 978k88.9542 - FAX
ADDRESS: 141 Stonecleave MAP:104B LOT: 13L
INSTALLER: Todd Bateson
DESIGNER: Anthony Korovos
PLAN DATE:4/15/2005
BOH APPROVAL DATE ON PLAN: 4/20/2005
DATE OF BED BOTTOM INSPECTION:5/13/2005
DATE OF FINAL CONSTRUCTION INSPE TLQNi/6/18/2005
DATE OF FINAL GRADE INSPECTION: 1,51 0'�
SELECT SYSTEM TYPE Pressure Dosing
COMPONENT SUMMARY FROM PLAN
GALLON TANK = 1500
LOADING OF SEPTIC TANK = H-10
GALLON PUMP CHAMBER = 1000
LOADING OF PUMP CHAMBER = H-10
TYPE OF SAS = Stone & Pipe Field
DIMENSIONS AND DETAILS OF SAS: 51 x 30
SITE CONDITIONS
EExisting septic tank properly abandoned
DInternal plumbing all to one building sewer
❑Topography not appreciably altered
Comments:
Page 1 of 4
TOWN OF NORTH ANDOVER OLI
Office of C'ONIMUNITY DEVE.L.01)NI ENT ADD SERV1(,JS
HEA1 141 DEdPART'MENT' to
27 CHARLES STREET m
NCRTH AND V ER, MASS C..'11 USE"TTS X91 STS
SLIS01 Y, Sawyer, RFAN/RS 978.6W9540 Phone
Flublic Health Director 978.688.9542 FAX
SEPTIC TANK
Bottom of tank hole has 6" stone base
Weep hole plugged
1500 gallon tank has been installed
H-10 loading Monolithic construction
Water tightness of tank has been achieved
(Visual or Vacuum Test or Water held for 24hrs)
Inlet tee installed, centered under access port
Outlet tee (gas baffle or effluent filter) installed,
centered under access port
24" inch cover to within 6" of final grade installed over
one access port, must be over outlet of tank if effluent
filter is present
Hydraulic cement around inlet & outlet
Comments:
PUMP CHAMBER
Bottom of tank hole has 6" stone base
Weep hole plugged
1000 gallon Pump Chamber installed
H-10 loading
Monolithic construction)
Inlet tee installed, centered under access port
Pump(s) installed on stable base
Alarm float working
Pump On/Off float working
Drain hole in pressure line
24" inch cover to within 6" of final grade installed over
pump access port
Water tightness of tank has been achieved
Visual testing
Hydraulic cement around inlet & outlet
Comments:
Page 2 of 4
111)WN OF NORTI-1 ANDOVER
Office of COMMUNUTY DEVELOPMENTAND SERVE ,'Ji11SQ1
1-1EALTI-1 DEPARTMEN11
27 C11ARLJ,.S STREET
N(.)R'1'11 AND0V ER, MASSA( f JUSETTS 0 1845
Susan Y. Sawyer, REIIS/RS 978.688.9540-- Phone
Public Health Director 978.688,9542 FAX
D-BOX
❑ Installed on stable stone base
® Inlet tee (if pumped or >0.08'/foot)
❑ Hydraulic cement around inlet & outlets
❑ Observed even distribution
F-1 Speed levelers provided (not required)
Comments:
Missing Hydraulic cement on pipes.
SOIL ABSORPTION SYSTEM
❑ Bottom of SAS excavated down to soil layer, as
provided on plan
Size of SAS excavated as per plan
Title 5 sand installed, if specified on plan
3/4-1 Y2" double washed stone installed
1/8-1/2" (peastone) double washed stone installed
laterals installed and ends connected to header (and
vented if impervious material above)
Orifices @ 5 & 7 o'clock positions
F-1 Gravelless disposal systems: type, number and
location as per plan
Elevations of laterals installed as on approved plan
40 Mil HDPE barrier installed
❑ Retaining wall (boulder/ concrete /timber/ block)
❑ Final cover as per plan
Comments:
CONTROLPANEL
Alarm & Pump are on separate circuits
Alarm sounds when float is tripped
❑ Location of control panel:
F-1 Rated for exterior if placed outside
Comments:
Page 3 of 4
TOWN OF NORTH ANDOVER
C It's
Office of OMMUNIT DE VELOPMENTAND SERV IC..
Y
FA
HEAL.111 DEPAR'I'NIEN'r wo
4
27 CIIARI-.,ES STREE'll'
N(,)R'I'H ANDOVER, MASSACHUSEITFS 01845
Susan Y. Sawyer, RE16/16 97&688,9540 Phone
Public Health Director 978.6W9542— I'M
SYSTEM ELEVATIONS
Benchmark: 132.00
Rod at Benchmark: 5.68
Height of Instrument: 137.68
INVERT ON DESIGN PLAN INVERT ELEVATION
Building Sewer OUT 128.70
Septic Tank IN 128.64 128.51
Septic Tank OUT 128.39
Pump Chamber IN 128.35
Pump Chamber OUT 129.71
Distribution Box IN
Distribution Box OUT 132.05 132.10
Manifold
Lateral I HIGH 132.00 132.07
Lateral 1 LOW 131.60 131.85
Lateral 2 HIGH 132.00 132.05
Lateral 2 LOW 131.60 131.85
Lateral 3 HIGH 132.00 132.10
Lateral 3 LOW 131.60 132.85
Lateral 4 HIGH 132.00 132.09
Lateral 4 LOW 131.60 131.83
Page 4 of 4
FW: 141 Stonecleave - Send Final Inspection Report Page 1 of 2
DelleChiaie, Pamela
From: Sawyer, Susan
Sent: Monday, June 13, 2005 2:59 PM
To: DelleChiaie, Pamela
Subject: RE: 141 Stonecleave - Send Final Inspection Report
Thanks, pis print out for the file. We should be close in getting some of these cold ones closed.
Susan
-----Original Message-----
From: DelleChiaie, Pamela
Sent: Friday, June 10, 2005 2:32 PM
To: Sawyer, Susan
Subject: FW: 141 Stonecleave - Send Final Inspection Report
HERE YOU C O_.
-----Original Message-----
From: Dan Ottenheimer [mailto:info @millriverconsulting.com]
Sent: Friday, June 10, 2005 1:26 PM
To: DelleChiaie, Pamela
Subject: RE: 141 Stonecleave - Send Final Inspection Report
Yes, sorry about that one.
Enjoy the weekend,
See attached,
Dan
Daniel Ottenheimer, President
Mill Fiver Consulting, Inn.
Septic,ystern Mana, errrent Ser vices
2 Blackburn ( enter
Gloucester, MA 01930-2251
978-282-0014 or 1-800-377-3044
fax: 978-282-0012
Nvww,nii l lrivercoiisulti ng.coni
(:latio((�,)nrillb°iverconstilt,iii .corii
From: DelleChiaie, Pamela [mai Ito:pdellechiaie @townofnorthandover.com]
Sent: Friday, June 10, 2005 10:57 AM
To: Daniel Ottenheimer (E-mail); Lisa LeVasseur (E-mail); McBrearty Andrew (E-mail)
Subject: FW: 141 Stonecleave - Send Final Inspection Report
Ili,
Can you send along the Final Inspection Report on above? Thanks.
P
$/4/2005
FW: 141 Stonecleave - Send Final Inspection Report Page 2 of 2
- .--Original Message----
From: DelleChiaie,Pamela
Sent: Thursday,June 09,2005 2:15 PM
To: 'Daniel Ottenheimer(E-mail)'; 'Lisa LeVasseur(E-mail)'; 'McBrearty Andrew(E-mail)'
Subject: 141 Stonecleave
Hello,
Did Susan send you the Bed Bottom Inspection info. for the above done on 5/13? If not, please let me
know, and I will send it. Thanks.
SON/N0010rds,
P10#1004 RWX04011#l401.0
Health Department Assistant
Town of North Andover
400 Osgood Street
North Andover,MA 01845
978.688.9540-Phone
978.688.8476-Fax
http://www,townofnort[lailclov r.coin
healthdept@townofnoi-thandover.com
8/4/2005
TOWN OF NORTH ANDOVER
Office of COMMUNITY DEVELOPMENT AND SERVICES
HEALTH DEPARTMENT
27 CHARLES STRUT
0 A
NORTH ANDOVER,MASSACHUSE17S 01845 'SACrIb S
Susan'Y, Sawyer,REHS/RS 978,688.9540-Phone
Public Health Director 978,688.9542-FAX
SEPTIC SYSTEM CONSTRUCTION NOTES
ADDRESS./l/2Z MAP: LOT.
INSTALLER: xxlf mn-%,
DESIGNER: I ".." t
,#,ps
PLAN DATE: A
--- 46,
BOH APPROVAL DATE ON PLAN'
DATE OF BED BOTTOM INSPECTION: _Z013 I T"
DATE OF FINAL CONSTRUCTION INSPECTION:
DATE OF FINAL GRADE INSPECTION:
SELECT SYSTEM TYPE
GRAVITY DISTRIBUTION
PRESSURE DISTRIBUTION
PRESSURE DOSING
HOLDING TANK
ADVANCED TREATMENT
"OTHER ..... .. ..... .... ....... ....... ...... ..................... ... ... ... .. ... ...... ........ .. ..... ............. ..... ... ........ .... .. . ..... ................ ....... . ... .. . ..... ....
COMPONENT SUMMARY FROM PLAN
GALLON TANK = R," Z,,�4",P
LOADING OF SEPTIC TANK
GALLON PUMP CHAMBER
LOADING OF PUMP CHAMBER
TYPE OF SAS =
DIMENSIONS AND DETAILS OF SAS:
SITE CONDITIONS
Existing septic tank properly abandoned
El Internal plumbing all to one building sewer
❑ Topography not appreciably altered
Comments:
Page 1 of 2
i
1
I
TOWN OF NORTH ANDOVER
Office of COMMUNITV DEVELOPMENT SERVICES
HE ALTH DEPARTMENT
27 CHARLES STREET
NORTH ANDOVER MASSACIWSETTS 01845 ACHUS
Susan Y. Sawyer,RLHS/RS 978,68&9540—Phone
Public Health Director 978,688.9542—FAX
J
SEPTIC TANK
%uP Bottom of tank hole has 6" stone base
,r Weep hole plugged
�� !,gallon tank ha, be, Installed
H- (�) monolithlc ►r 2 piece)
r; ightness of tank has been achieved
("Visu l'A' r Vacuum Test or Water held for 24hr )
Inlet tee installed,.under access part
Outlet tee (gas ba 'I or effluent filter) installed, under
access port h'
inch cover to within 6" of final grade installed over
one access part, must be over outlet of tank if effluent
filter is present
Hydraulic cement around inlet & outlet
Comments:
PUMP CHAMBER
*r"'' ' Bottom of tank hole has 6" stone base
Weep hole plugged
f; v allon Pump Chamber installed
(H-10 or H-20) (monolithic or 2 piece)
Inlet tee installed, under access port
Pump(s) installed on stable base
El Alarm float working
El Pump On/Off float working
Drain hale in pressure line
❑ inch cover to within 6" of final grade installed over
one access part
Water tightness of tank has been achieved
Visual or Vacuum Test or Water held for 24 hrs
El Hydraulic cement around inlet & outlet
Comments:
Page 2 of 2