HomeMy WebLinkAboutCorrespondence - 69 OAKES DRIVE 9/16/2004 y �......,, ,_.....��,........ .,....�... . _. .. ......................................... ,........,, ........ ...__................ ..._. ........................... ....�
NEW ENGLAND ENGINEERING SERVICES
INC.o
September 16, 2004
RECEIVED d
Susan Sawyer SEP J, 6 2004
North Andover Board of Health
27 Charles Street TOWN OF NORTH ANDOVER
H ALTH DI 9=AR C`MIwNI'
North Andover, MA 01845 -°° m-
Re: 69 Oakes Drive, North Andover
Septic System Design
Dear Susan,
The following plans and enclosures for the above referenced property are being submitted
for approval.
1. (5) Copies of the Septic System Design Plans.
2. (1) Copy of the Form 11 Soil Evaluator Sheets.
3. (1) Copy of the Form 12 Percolation Test Sheet
4. (1) Check for payment of the Town approval fee.
If you have any comments or questions please do not hesitate to contact this office.
Sincerely,
Steven E. Pouliot
Project Manager
60 BEEC;HWOOD DRIVE.-NOR-rH ANDOVER, MA 01845..(976)686-1768-(666)359--7645- FAX(976)665-1099
Town of North Andover
HE ALTD DEPARTME NT
27 Charles Street
North Andover,MA 01845
978.688.9540
s
healthde S � a ta
HEALTH DEPARTMM,4''r
SEPTIC PLAN SUBMITTAL L FORM
DATE OF SUBMISSION:
SITE LOCATION:
ENGINEER. l / 4 'q(j- ly r 'W,11-11_11 ` '1A1,1
$225.00/Plan Check#:
NEW PLANS: 'YES '"� ��
(Includes and one Re-Review Only)
REVISED PLANS: YES $75.00/Plan Cheek#:
SITE EVALUATION FORMS INCLUDED: ES NO
LOCAL UPGRADE FORM INCLUDED: YES NO
Telephone#: (:1 _ 17 Fag#:
E-mail:
HOMEOWNER NAME: MICA 1.- K iz 1,w-F4
OFFICE USE ONLY
When the submission is complete (including check):
1. "" Dote stamp plans and letter
2 ° Complete and attach Receipt
3. Z """ opy-File, ForwardtoConsultant
4 --," Enter on Log Sheet and Database
... ... ......................... .........—------_---—......................—------- ,. ...... ............. ..... ,�.,...... .........�
NEW ENGINEERING SERVICES
�..........�.. .... . INC ,. .. o
5s
September 17, 2004
Susan Sawyer
North.Andover Board of Health
27 Charles Street O\N� w �
North Andover, MA 01845
Re: 69 Oakes Drive., North Andover,MA
Local Bylaw Waiver Request
Dear Susan,
The purpose of this letter is to request that the above referenced property be included in
the upcoming Board of Health meeting agenda to discuss the following variances:
Local Bylaw Waivers Required
1. Allow reduction in offset distance between leach bed and wetlands from 100 feet
required to 53 feet.
If you have any comments or questions please do not hesitate to contact this office.
Sincerely,
Steven E. Pouliot
c r.,
Project Manager
d ey
60 BEECIAWOOD DRIVE-NORTH ANDOVER, MA 01845..(973)686-1768-(866)359.7645• FAX(976)665-1099
09/17/2004 09:JU JIUbU"IUJJ I r.I1Jaar4r-r-M .i4sa ZDvt wae v.<
lkNew England FAX TRANSMITTAL
Engineering Services,Inc.
60 Beechwood D ' e,No. Andover,MA 01845 www.newenglandengineerft.nct
Phone; 979.686.1768 Fax: 979. 5.1099
Date : September 17,2004
>Fax V q 76`- "6
Please Deliver To: Susan Sawyer
CompwW Nance! North Andover Board of Health
Address :
N DE
From: Steven E. Pouliot
RE ; 100 Raleigh')cavern Lam,North Andover
°'.W`� 69�4alcca t2riv�,;�l�fo` Arid®ver
Dear Susan,
i Atta+ctied please find a request for to BOW of H iug ag s to discuss
Local Bylaw Waiver requests for the above referenced pr ies,
Thank you,
I
Urgent Reply Requested Reply Today
x Reply at Your Own Conlveniearce No Reply Necessary
3 Total Paset,including CeVer Sheet. (if all pager are Mar"oelvod,pleasv Matifjo our fi""ae soon a®possible.)
b`9/L//'Li717q by:jtl /tlbtl51l7j i Nt tNUINttKINU 5VU r!-OUC uc
N W N N ENGINEERING/ SERVICES
INC
i
I
I
September 17,2004
I
Susan Sawyer
North Andover Board of Health
27 Charles Street
North Andover,MA 01 845
I Re: 69 Oakes Drive,North Andover,MA
Local Bylaw Waiver Request
I
• Dear Susan,
The purpose of this letter is to request that the above referenced property be included in
the upcoming Hoard of Health meeting agenda to discuss the following variances:
Local BBylaw Waivers Req fired
1. Allow reduction in offset distance between leach bed and wetlands from 100 feet
j required to 53 feet.
If you have any comments or questions please do not hesitate to contact this office.
Sincerely,
i
I
Steven E.Pouliot
Project Manager
i
I
60 SEECHWOM VRIVE-NORTH ANDOVER,MA 01845-(978)606-1768 (888)359.7048•FAX(070)685.1099
'TOWN OF' NORT11 ANDOVER
Office of COMMUNITY DEVELOPMENTAND SERVICES
HEALTH DEPARTMENT
27 CHARl ES STREET
NORTH ANDOVER, MAS AC."l-USlsTT'S O1845 C�4+����
Susan Y. Sawyer, REIIS/R.S 978.688.9540 Phone
Public Health Director 978.688.9542 I�A
September 30,2004
Benjamin Osgood, P.E.
New England.Engineering Services,Inc.
60 Beechwood Drive
North Andover,MA 01845
Re: 69 Oakes Drive,Map 107A,Lot 143
Dear Mr. Osgood:
The proposed septic system design plans for the above site dated September 15,2004 and received on September 16,
2004 has been reviewed. Unfortunately, it cannot be approved until the following items are corrected. The specific
section in Title 5: 31.0 CMR 15.000,or North Andover regulation that is not met by this design follows each item.
1. No waterline is shown on plan. -220(4)(m)
1 Please provide a detail for the distribution box,as none is shown on plan.
3. Please specify the finish grade over the septic tank and pump chamber. It appears that there is not
sufficient cover over pump chamber using existing grade. -228(1)
4. A retaining wall is required if the slope of 3:1 cannot be obtained. See the document issued by the
Massachusetts Department of Environmental Protection titled"GUIDELINES FOR DESIGN AND
INSTALLATION OF IMPERVIOUS BARRIERS AND SLOPE STABILIZATION FOR TITLE 5 m
SYSTEMS"for more information. µ.
..
�.. u�"T �,arM� } Y.-� � r r '��_ .b e.�a t,,._J'C4 r_r„4„,..
Additionally,you might wish to consider placing the electric junction box outside of the pump chamber to prevent
corrosive gases from entering box.
Please feel fi-ee to contact the office with any questions you may have. We look forward to working with you to
obtain a septic system which will be in compliance with all regulations and assure protection of public health and the
environment of North Andover.
Siner"
� agan Y. Sawyer,REHS/RS �
Public Health Director
cc: Owner
File
TOWN OF NORTH ANDOVER HO"Th
Office of COMMUNITY DEVELOPMENT AND SERVICES
HEALTH DEPARTMENT
27 CHARLES STREET °„, -,�•
NORTH ANDOVER, MASSACHUSETTS 01845 CAUS
Susan Y. Sawyer,REHS/RS 978.688.9540—Phone
Public Health Director 978.688.9542—FAX
October 8,2004
Benjamin Osgood,P.E.
New England Engineering Services, Inc.
60 Beechwood Drive
North Andover, MA 01845
Re: 69 Oakes Drive,Map 107A,Lot 143
Dear Mr.Osgood:
The proposed septic system design plans for the above site dated September 15,2004 and received on September 16,
2004 has been reviewed. Unfortunately, it cannot be approved until the following items are corrected. The specific
section in Title 5: 310 CMR 15.000, or North Andover regulation that is not met by this design follows each item.
1. No waterline is shown on plan. -220(4)(m)
2. Please provide a detail for the distribution box,as none is shown on plan.
3. Please specify confirmation of wetland delineation on the south side of the property.
4. Please specify the finish grade over the septic tank and pump chamber. It appears that there is not
sufficient cover over pump chamber using existing grade.-228(1)
5. A retaining wall is required if the slope of 3:1 cannot be obtained. See the document issued by the
Massachusetts Department of Environmental Protection titled"GUIDELINES FOR DESIGN AND
INSTALLATION OF IMPERVIOUS BARRIERS AND SLOPE STABILIZATION FOR TITLE 5
SYSTEMS”for more information. Please review slopes without a wall and revise to 3:1 as needed.
Additionally,you might wish to consider placing the electric junction box outside of the pump chamber to prevent
corrosive gases from entering box.
Please feel free to contact the office with any questions you may have. We look forward to working with you to
obtain a septic system which will be in compliance with all regulations and assure protection of public health and the
environment of North Andover.
Sincere ,
�r S an
YY Sawyer,REHS/
ublic Health Director
cc: Owner
File
.,�.�.�....._ ....�,.. . .
NEW ENGLAND ENGINEERING SERVICES
October 21, 2004
Susan Sawyer
North Andover Board of Health 0 CT 2004
27 Charles Street
North Andover, MA 01845
Re: 69 Oakes Drive, North Andover
Revised Septic System Design
Dear Susan,
The following plans and enclosures for the above referenced property are being
resubmitted for approval.
1. (3) Copies of the Revised. Septic System Design Plans.
Please note that the plans have been revised to address comments from your letter dated
October 8, 2004.
If you have any additional comments or questions please do not hesitate to contact this
office.
Sincerely,
Steven E. Pouliot
Project Manager
60 BEECHwOOD DRIVE-NOR"I'li ANDOVER, MA 01845-(978)686-1768-( 88)359-7645.. FAX(9.78)585-1 099
TOWN OF NORTH ANDOVER f pORTh
Office of COMMUNITY DEVELOPMENT AND SERVICES 3� • ��
HEALTH DEPARTMENT o ' ~
27 CHARLES STREET
NOR i I ANDOVER, NLASSACHUSETTS 01845 "IS CHUSEt�
Susan Y. Sawyer 978.688.9540—Phone
Public Health Director 978.688.9542 —FAX
October 25, 2004
Michael Carey
69 Oakes Drive
North Andover, MA 01845
RE: Subsurface Sewage Disposal System Plan for 69 Oakes Drive, Map 107A, Parcel 143,
North Andover, Massachusetts
Dear Mr. Carey,
The North Andover Board of Health has completed the review of the septic system design plans,
for the above referenced property, submitted on your behalf by New England Engineering
Services dated September 15, 2004, last revised October 15, 2004.
The design has been approved for use in the construction of an onsite septic system. This
approval is valid for three years from the date of this letter and during this time a licensed septic
system installer must obtain a permit and complete this work, and a Certificate of Compliance
must be endorsed by the installer, designer and the Town of North Andover. The time period for
which this plan is valid is reduced to two years from the date of a septic system inspection that
did not meet the acceptable criteria in the state regulations. In the event an imminent health
problem such as sewage backup into the dwelling is occurring, the North Andover Board of
Health may reduce the time period for which this plan is valid.
This plan received the approval of a variance to the local subsurface regulations from the North
Andover Board of Health at their meeting on September 23, 2004. The variance approved was a
reduction in the offset distance between the leach area and a wetland from 100 feet to 53 feet.
This approval is for an existing 5-bedroom(or total of 11 rooms) house is subject to the
following conditions:
1. If site conditions are found in the field to be different from those indicated on the
design plan and/or soil evaluation, the originally issued Disposal System Construction
Permit is void, installation shall stop, and the applicant shall reapply for a new
Disposal Systems Construction Permit (3 10 CMR 15.020(1)).
2. It is the responsibility of the applicant and/or the applicant's septic system designer,
septic system installer or other representative to ensure that all other state and
municipal requirements are met. These may include review by the Conservation
Commission, Zoning Board, Planning Board, Building Inspector, Plumbing Inspector
and/or Electrical Inspector. The issuance of a Disposal --stem Construction Permit
shall not construe and/or imply compliance with any of the aforementioned
requirements.
Your effort to provide a properly functioning septic system for your dwelling is greatly
appreciated. The Health Department may be reached at 978-688-9540 with any questions you
might have.
Sincerely,
_ S*n Y. Sawyer, REHS S
Public Health Director
cc: New England Engineering Services
file