Loading...
HomeMy WebLinkAboutCertificate of Compliance - 39 PADDOCK LANE 5/9/2016 ® S�T'CL�nl6y6` ryr,. PUBLIC HEALTH DEPARTMENT Torn of North Andover Community Development Division CERTIFICATE U11 Ch As ® 5/9/1 This is to certify that the individual subsurface disposal system received a SATISFACTORY INSPECTION of the: Repair of D-Box and Tank Y® Todd Bateson Andover,Ate 39 Paddock Lane Map 107.D Lot 0097 North MA 01845 The Issuance of this certificate'`shall not be construed as a guarantee that the system will function satisfactorily. ';J Michele Grant Public Health Agent 1600 Osgood Street,North Andover,Massa(husetts 01845 Phone 978.688.9540 Fax 978.688.8476 Web www.townofnorthandover.com North Andover Health Department Community anal Economic Development Division ONSITE WASTEWATER SYSTEM T UCTl N NOTES LOCATION INFORMATION ADDRESS: 39 Paddock Lane MAP: 107.D LOT: 0097 INSTALLER: Todd Bateson DESIGNER: PLAN DATE: BOH APPROVAL DATE ON PLAN: INSPECTIONS Tank and D-Box INSPECTION: 5/9/16 DATE OF BED BOTTOM INSPECTION: DATE OF FINAL CONSTRUCTION INSPECTION: DATE OF FINAL GRADE INSPECTION: SITE CONDITIONS ❑ Contractor reports any changes to design plan X Existing septic tank properly abandoned ❑ Internal plumbing all to one building sewer ❑ Topography not appreciably altered Comments: SEPTIC TANK ❑ Building sewer in continuous grade, on compacted firm base ❑ Cleanouts per plan X Bottom of tank hole has 6" stone base X Weep hole plugged X 1500 gallon tank has been installed H-10 loading X Monolithic tank construction ❑ Watertightness of tank has been achieved by visual testing ❑ Inlet tee installed, centered under access port ❑ Outlet tee installed, centered under access port (gas baffle/effluent filter) ❑ inch cover to within 6" of finish grade installed over one access port ❑ Hydraulic cement around inlet & outlet Comments: PUMP CHAMBER ❑ Bottom of tank hole has 6" stone base ❑ Weep hole plugged ❑ 1500 gallon Pump Chamber installed ❑ H-10 loading ❑ Monolithic tank construction ❑ Inlet tee installed, centered under access port ❑ Pump(s) installed on stable base ❑ Alarm float working ❑ Pump On/Off floats working ❑ Separate on/off floats ❑ Drain hole in pressure line ❑ cover at final grade installed over pump access port ❑ Water tightness of tank has been achieved by testing ❑ Hydraulic cement around inlet & outlet Comments: CONTROL PANEL ❑ Alarm & Pump are on separate circuits ❑ Alarm sounds when float is tripped ❑ Location of control panel: basement ❑ Alarm signal located inside: basement Comments: DISTRIBUTION-BOX X Installed on stable stone base X H-20 D-Box X Inlet tee (if pumped or >0.08'/foot) X Hydraulic cement around inlet & outlets X Observed even distribution X Speed levelers provided (not required) X Schedule 40 PVC Pipe Comments: