Loading...
HomeMy WebLinkAboutCertificate of Compliance - 700 MIDDLETON STREET 5/16/2016 e ° ® S�q FLED, : ,o 0 PUBLIC HEALTH DEPARTMENT Town of North Andover Community Development Division CERTIFICATE 0"F Cu" MPLIANCE As of: 5/16/16 This is to certify that the individual subsurface disposal system received a SATISFACTORY INSPECTION of the: Full Repair of an On-Site Sewage Disposal System By: Jay Wadsworth Ate 700 Middleton Street Map, 109 Lot North Andover, A T ssuance of this certr icate shall not be construed as a guarantee that the system will function satisfactorily. lVfichele Grant , J Public Health Agent 1600 Osgood Street,North Andover,Massachusetts 01845 Phone 978.688.9540 Fax 978.688.8476 Web www.townofnorthandover.com a North Andover Health Department Community and Economic Development Division QNSITE WASTEWATER Y T M CONSTRUCTION NO LOCATION INFORMATION ADDRESS: 700 Middleton St. MAP: 109 LOT: 29 INSTALLER: Jay Wadsworth DESIGNER: James Morin PLAN DATE: 5/25/15, Rev 9/25/15 BOH APPROVAL DATE ON PLAN: INSPECTIONS TANK INSPECTION: 11/18/15 re-inspection on 12/16/15 DATE OF BED BOTTOM INSPECTION: DATE OF FINAL CONSTRUCTION INSPECTION: 12/18/15 DATE OF FINAL GRADE INSPECTION: 06 SITE CONDITIONS ® Contractor reports any changes to design plan X Existing septic tank properly abandoned 11/30/15 ® Internal plumbing all to one building sewer ® Topography not appreciably altered Comments: SEPTIC TANK ❑ Building sewer in continuous grade, on compacted firm base ® Cleanouts per plan X Bottom of tank hole has 6" stone base X Weep hole plugged X 1500 gallon tank has been installed H-10 loading ❑ Monolithic tank construction ® Water tightness of tank has been achieved by visual testing ® Inlet tee installed, centered under access port ® Outlet tee installed, centered under access port (effluent filter) ® 24" inch cover at finish grade installed over one access port ❑ Hydraulic cement around inlet & outlet Comments: placed p-stone in hole instead of 3/" which is shown on the plan. Jay will remove and replace with appropriate stone. Hit ledge bought a plastic tank. (Roth Tank) Tank had to be turned and a portion is now in the overdig. Discussed with Jay Wadsworth, the installer, to evaluate the elevations and pitch with the designer and that all is in accordance with the plan. *Elevations and pitch was incorrect (stop work) New pipe was raised 12" above old pipe, foundation to tank 12'. Plastic tank 12" of stone because of the placement of the tank due to ledge, the d-box will be placed at the end of the tank instead of in between tank and field. Jay indicated the elevation coming out of the house is 98.98 plan says 101 please check all elevations thoroughly 12/18/15 — Building sewer pipe not supported or bedded for much of the length of it. No hydraulic cement required because rubber grommets at tank inlet and outlet. Roth poly tank backfilled with sand or soil, not peastone. Installer instructed to examine the approval for the tank to confirm acceptability of backfill. DISTRIBUTION-BOX ® Installed on stable stone base ® H-20 D-Box ® Inlet tee (if pumped or >0.08'/foot) ® Hydraulic cement around inlet & outlets ❑ Observed even distribution ❑ Speed levelers provided (not required) ❑ Schedule 40 PVC Pipe Comments: 12/18/15 — Pipes exiting the distribution box were not level at all within the box so no even flow could be achieved. Pipes exiting distribution box were not level for 2' out beyond the box. SOIL ABSORPTION SYSTEM (General) ❑ Bottom of SAS excavated down to C soil layer, as provided on plan ® Size of SAS excavated as per plan M Title 5 sand installed, if specified on plan ❑ 40 Mil HDPE barrier installed ❑ Laterals installed and ends connected to header (and vented if impervious material above) ® Elevations of laterals and chambers installed as on approved plan ❑ Retaining wall (boulder/ concrete /timber/ block) ❑ Final cover as per plan Comments: 24'Lx16'W 29'Lx26'W with overdig 12/8/15 — SAS size correct SOIL ABSORPTION SYSTEM (gavel-less Chambers) ® Brand and Model of Chamber: Cultec C4 ® Number of chambers per row: 3 ® Number of rows (trenches): 4 Comments: Total Chambers = FINAL GRADE ❑ r Laamed ❑ Seeded ❑ Cover per plan Comments: DOCUMENTS NEEDED ❑ Certification of Installation Farm submitted By engineer and signed and dated by Engineer and installer As-Built Plan BM = 100.00 HR = 3.03 HI = 103.03 a ° A'\ ( 16 SYSTEM ELEVATIONS ROD AS-BLT INVERT DESIGN INVERT ELEVATION ELEV ELEV Benchmark Building Sewer OUT 3.67 99.03 Septic Tank IN 4.21 98.49 Septic Tank OUT 4.44 98.26 Distribution Box IN 4.58 98.12 Distribution Box OUT 4.76 97.94 Lateral 1 TOP 4.79 98.24 Lateral 1 INVERT 4.90 97.80 Lateral 2 TOP 4.80 98.23 Lateral 2 INVERT 4.90 97.80 Lateral 3 TOP Lateral 3 INVERT 4.90 97.80 Lateral 4 TOP Lateral 4 INVERT 4.90 97.80 SKETCH PLAN CRITICAL SETBACK DISTANCES Mark those distances checked in the field against the design plan and regulatory setback Tank SAS Sewer ❑ Property line 10 10 -- ® Cellar wall 10 20 -- ❑ Inground pool 10 20 -- ❑ Slab foundation 10 10 -- ❑ Deck, on footings, etc 5 10 -- ❑ Waterline 10 10 101 ® Private drinking well 75 1002 50 1 Suction line 222(2) ❑ Irrigation well 75 100 ❑ Surface Water 25 50 ❑ Bordering Vegetated Wetland , Salt Marsh, Inland/Coastal Bank 75 100 ❑ Wetlands bordering surface water supply or trib. (in Watershed) 150 150 ❑ Trib. to surface water supply 325 325 ❑ Public well 400 400 ❑ Interim Wellhead Prot. Area ❑ Reservoirs 400 400 ❑ Drains (wat. supply/trib.) 50 100 ❑ Drains (intercept g.w.) 25 50 ❑ Drains (Other)Foundation 10(5) 20(10) ❑ Drywells 20 25 12/18/15 —Distance from SAS to well on subject property 79'. Distance to wall of house 12' - note that design plan shows a distance of 23.5' but that is inaccurately depicted and is likely the distance to the inner wall of the house, not the outer wall of the house. 2 100 feet is a minimum acceptable distance and no variance is allowed for a lesser distance(NA 5.02). s As defined in 310 CMR 10.55, 10.32, 10.54,and 10.30,respectively,pursuant to 15.211(3),also by NA wetland bylaws The Fischer Family M:&Mrs.Martin S.Fischer 700 Middleton Road North Andover,MA 01845 978-683-3630 May 18,2016 zmartvz@aol.com Michelle E. Grant Public Health Agent Town of North Andover 1600 Osgood Street Suite 2035 North Andover,MA 01845 Dear Ms.Grant, Subject: 700 Middleton Street Confirming our telephone conversation of the 16"'regarding the completion of the project,I will hereby assume responsibility for the final grade. You had agreed that if•I,do so,,that you would be able to issue a certificate of compliance. Thank you for your help over the past year. Sincerely, Martin S.Fischer °To of North Andover — Se tic S ste a AS-BUILT CHECKLIST 1) A11 changes to the design plan have been reflected and noted on the as-built plan 2 T"As-buill plan has a suitable scale; 0 inch = 40 feet or fewer for lot plans) p � p p 3) Street Address,Assessor's Map and Lot Number 4) of Lines and Location of Dwellings served by the system 5) Locations,Elevations and Dimensions of As-built system components,including reserve (if applicable) 6) Ties to all tank openings,d-boa,and leach area from dwelling or Permanent Structure 7) Setback distanc s are shown on the as-built plan from system components to: ubsurface,interceptor&foundation drains atch basins Property lines ellings or other structures rivate water supply or irrigation wells RECEIVED Watercourses or wetlands $) .ovations of Wells,Drains,Wetland Resource Areas within 150 feet of system TOWN OF tiC�t TFi ANDOVER 9) ocation of water,gas,electric lines,cable,control panel (if applicable) 11 t:111 DEPARTMENT 10) 6ation of Structures within 6 Inches of Finished Grade ll) Original Stamp&Signature 12) 71rr cation and holder of any easements which could impact the system. 13 ery ious Areas•Drivewa s etc ) p � Y � 14') orth Arrow 15) /Location &Elevation of Benchmark used 16) STATEME 'ON PLAN (NA 5.3) a. "I certify the locations,elevations, ties,cover material;exposed component coverts etc., shown on this as-built suhstantially agree with the approved plan and have determined that the break ozz tion s,if applicable,have been met," Sign=XA igner Date b. " I, WAL L IS Pli'L'SEAT W 4.9)a Letter or statement on the as-built indicator z the wall- was, or was not,constr ucted in accordance with the intended desr,;n and any manufacturer's specifzcations." Signature of Designer Date As of:Tuesday,March 17,2015 Tovm of ver — Septic stem I ` T 1) All changes to the design plan have been reflected and noted on the as-built plan 2) As-built plan has a suitable scale; (1 inch = 40 feet or fewer for plot plans) 3) /Street Address,Assessor's Map and Lot Number ' 1) Lot Dines end Location of Dwelling ..served by the system 5 cat io.n. s' levatio.,n s`an <.. im.. en s ions �A -built s y stem components,z naltdin g°rese reserve (if applicable) 6) Ties to all tank openings,d-3box,and g t Structtit�e and leach area ftorax dwellin or Permanent 7) Setback distances are shown on the as-built plan from system components to: Subsurface,interceptor&foundation drains Catch basins Property lines Dwellings or other structures 77, Private water supply or irrigation wells Watercourses or wetlands 0) Locations of ells,Drains,Wetland Resource Areas within 150 feet of system 9) cation of water,gas,electric lines,cable,control panel (if applicable) 10) Location of Structures within 6 Inches of Finished Grade 11) Original Stamp&Signature 12) ALocation and holder of any easements which could impact the system 13) Impervious Areas;Driveways,etc 14) \ North Arrow 15) Location &Elevation of Benchmark used 16 ',., STATEMENT ON PLAN (NA 5.3) �.,.,.. � ��., �, �- `�,�(� d (��J i �, � � � � Y a. "1 certify the locations, elevations, ties, cover material,e1j.?osed component covers e shown on tivs as-built substantially agree with the approved plan and have detern ned that the break out elevations;if applicable,have been inet." Signature of Designer Date b. "If a STUCTURAL WALL IS PRESENT(NA 4.9)a Letter or statement on the as-built indicating the wall- was, or was not,;constructed in accordance with the intended desi�n and any manufacturer's specifications." Signature of Designer Date Revised 3/17/15 edge, Lisa From: Dan Ottenheimer <dano @millriverconsulting.com> Sent: Friday, December 18, 2015 5:28 PM To: Grant, Michele; Hadge, Lisa Cc: 'Isaac Rowe'; Pam Lally Subject: Construction Inspection - 700 Middleton Street Attachments: 700 Middleton St. Construction Inspection.doc; Roth Tank Approval -w054018.pdf, p511032rev3 proof.pdf Attached please find the results of the construction inspection performed at this address. The construction of the leaching facility portion of the system was found to be acceptable. Several issues were identified in relation to the components prior to the leaching facility. Outstanding issues which were identified are as follows: 1. The building sewer pipe exiting the dwelling towards the septic tank was not backfilled to provide adequate support against settling. 2. The septic tank used is a Roth Multitank. The MassDEP approval section IV 4 (attached) requires the installer be certified to put these tanks in the ground. Mr.Wadsworth indicated he believed he was certified and was going to check his paperwork. Relatedly, the tank was backfilled with sand, not pea gravel, and at the time out in the field I was not sure if that was acceptable or not. I have now reviewed the approval for these tanks and the associated installation manual and it does say clean sand is acceptable as long as the sand or pea gravel is placed inside the bumps (haunches, as they call them) of the tank(attached). I did not get to discuss this with Mr. Wadsworth but from the parts of the tank that I saw, this type of backfilling was not completed. Mr.Wadsworth was instructed to investigate the tank installation in general as well as the MassDEP approval further, and was instructed that as the licensed installer he is expected to maintain compliance with all relevant approvals at the construction project. 3. The distribution box was poorly constructed with one or several pipes protruding through the wall at a steep angle and thus even flow exiting the box could not be provided. The pipes were also not level for the first 2' exiting the box. Mr. Wadsworth was told the soil absorption system was completed adequately and he was free to backfill it, but that the area around the piping, tank and distribution box was to remain exposed for further work and inspection. Mill Rivell, consulting Daniel Ottenheimer, President Mill River Consulting, Inc. 6 Sargent Street Gloucester, MA 01930-2719 1