HomeMy WebLinkAboutCertificate of Compliance - 400 SHARPNERS POND ROAD 6/16/2016 ® SETTLED 16,
•
■
PUBLIC BLIC HEALTH DEPARTMENT
Town of North Andover
Community Development Division
T
COMPLIANCE
As of.- 6/16/2016
This is to certify that the individual subsurface disposal system received a
SATISFACTORY INSPECTION of the:
Repair of Baffle, Riser and D-Box
By: John DiVincenzo
Ate
400 Sha s Pond Road
Map 090.B Lot 0047
} North Andover,
The, suance of this ce � cate shall not bd construed as a guarantee that the system will function satisfactorily.
� f
Mi hele Grant
Public Health Agent
1600 Osgood Street,North Andover,Massachusetts 01845
Phone 978.688.9540 Fax 978.688.8476 Web www.townofnorthandover.com
North Andover Health Department
Community and E(onomic Development Division
N ITE WASTEWATER SYSTEM CONSTRUCTION NOTES
LOCATION INFORMATION
ADDRESS: 400 Sharpners Pond Rd. MAP: 090.8 LOT: 0047
INSTALLER: John DiVincenzo
DESIGNER:
PLAN DATE:
BOH APPROVAL DATE ON PLAN:
INSPECTIONS
Baffle and riser and d-box INSPECTION: 6/16/16
DATE OF BED BOTTOM INSPECTION:
DATE OF FINAL CONSTRUCTION INSPECTION:
DATE OF FINAL GRADE INSPECTION:
SITE CONDITIONS
❑ Contractor reports any changes to design plan
❑ Existing septic tank properly abandoned
❑ Internal plumbing all to one building sewer
❑ Topography not appreciably altered
Comments:
SEPTIC TANK
❑ Building sewer in continuous grade, on
compacted firm base
❑ Cleanouts per plan
❑ Bottom of tank hole has 6" stone base
❑ Weep hole plugged
❑ 1500 gallon tank has been installed
H-10 loading
❑ Monolithic tank construction
❑ Water tightness of tank has been achieved by
visual testing
❑ Inlet tee installed, centered under access port
",.Outlet tee".","O " installed, centered under access port
(gas.baffl.e/effluent filter)
i nch h
9nst lle ove.r..lo-with.i.n 6" of finish grade
one access port
❑ Hydraulic cement around inlet & outlet
Comments:
PUMP CHAMBER
❑ Bottom of tank hole has 6" stone base
❑ Weep hole plugged
❑ 1500 gallon Pump Chamber installed
❑ H-10 loading
❑ Monolithic tank construction
❑ Inlet tee installed, centered under access port
❑ Pump(s) installed on stable base
❑ Alarm float working
❑ Pump On/Off floats working
❑ Separate on/off floats
❑ Drain hole in pressure line
❑ cover at final grade installed over pump
access port
❑
Watertightness of tank has been achieved by
testing
❑ Hydraulic cement around inlet & outlet
Comments:
CONTROL PANEL
❑ Alarm & Pump are on separate circuits
❑ Alarm sounds when float is tripped
❑ Location of control panel: basement
❑ Alarm signal located inside: basement
Comments:
DISTRIBUTION-BOX �
\" / Installed on stable stone base
❑ H-20 D-Box
Inlet tee (if pumped or >0.08'/foot)
Hydraulic cement around inlet & outlets
Observed even distribution
❑" Speed levelers provided (not required)
Schedule 40 PVC Pipe
Comments: ' "`
e