HomeMy WebLinkAboutPlans - 12 LAVENDER CIRCLE 6/14/2016 l TYPICAL OF 2 TYPICAL 1 THRU 13 (1) LG i 315N1C-G4 (2) SOLAREDGE 315 WATT P300 OPTOMIZER PROPOSED EQUIPMENT SPECIFICATIONS MONO Imax 15A 3 SOLAREDGE SE7600A-US Vmax 35V A (1)SOLAR MODULES-LG 315N1C-G4 315 WATT DC-STC B 5 p:9.50A Vmp:33.2V DC AC Isc:10.02A Voc:40.6V TYPICAL 1 THRU 10 aoA STRINGS OF 18 MODULES (2)SOLAREDGE POWER OPTIMIZER STRINGS ax:35V.ULtIEEE LISTED (1) LG 30A POWER EQUIPMENT 315N1C-G4 (2) SOLAREDGE (3)SOLAREDGE SE760OA-US INVERTER 315 WATT P300 OPTOMIZER Imax:35 @ 240V 1 PHASE 60HZ MONO Imax 15A (4)SOLAREDGE SE6000A-US INVERTER Vmax 35V A Imax:22 @ 240V 1 PHASE 60HZ DC AC B (5)100A RATED MLO 240V 1 PHASE 60HZ,WITH QTY 1 40A 2 POLE BREAKER,AND QTY 1 30A 2 C) POLE BREAKER {4}SOLAREDGE SE6000A-US (6)CUSTOMER OWNED REVENUE GRADE 6 {7)100A 600V NEMA 3 INDOOR FUSED DISCONNECT WITH 70A FUSES UM RM (8)100A 600V NEMA 3R OUTDOOR UNFUSED UTILITY DISCONNECT (10} (9)POINT OF INTERCONNECTION LINE-SIDE g 7 TAP INSIDE EXISTING 200A MAIN BREAKER 9 C SERVICE PANEL j (10)EXISTING 200A MAIN ELECTRIC6ERVICE PANEL WITH 2O0A MAIN BREAKER 240V SINGLE C C PHASE 'I TO UTILITY a I I i GENERAL NOTES WIRE AND CONDUIT SIZING ALL WIRES EXPOSED TO AIR SHALL BE PV-WIRE 1. BOND THE COMBINED INVERTER DC I AC GROUND TERMINAL DIRECTLY TO THE MAIN SERVICE GROUND. AWG #12110.ALL OTHER CONDUCTORS SHALL BE 2. INVERTERS SHALL BE LISTED TO UL/IEEE STANDARDS COPPER THWN-2 t THHN. 3. ALL WORK SHALL CONFORM TO NEC 690 LOCAL AUTHORITIES HAVING JURISDICTION AND CUSTOMER REQUIREMENTS (A)2 AWG#10 PV WIRES Wt AWG#8 GEC EXPOSED 4. DISCONNECT SWITCHES SHALL HAVE NUMBER OF POLES REQUIRE TO DISCONNECT ALL CONDUCTORS (B)3 AWG#8 Wt AWG#8 GEC IN 314"EMT PER NEC 690. (C)3 AWG#6 Wt AWG#8 GEC IN 314"EMT 5. PV MODULES SHALL BE LISTED TO UL STANDARD 1703. 6. SECURE BUILDING PENETRATIONS WATERTIGHT ROOF AND WALLS 7. WIRING TO BE IN ACCORDANCE WITH MANUFACTURE RECOMMENDATIONS AND NEC 690 8. INTERIOR EQUIPMENT SHALL BE NEMA 1(MIN)AND EXTERIOR EQUIPMENT SHALL BE NEMA 3R(MIN). = 9. PROVIDE ALL GROUNDING AND BONDING AS REQUIRED PER NEC 690 AND 250. 10. INSULATION WILL MEET 2014 NEC MINIMUM REQUIREMENTS AND LOCAL CODE SPECIFICATIONS. HARD 11. DC GROUND ELECTRODE BONDED TO AC GROUNDED ELECTRODE AS PER NEC 696-47. Invaleon Technolo- Co tion Project Name �pTs Date 5191201 6y Tom K W. C�ey g es rpoa Loth Residence Titles.Electrical i-Line _ 26 Paricr dge Road Sod.i 6 .1.1.1DesktoRtinvaleon 420x0.png D H th II MA01835 St.Address: rawmg:1 Description.Electrical i-Line _ ¢ valeonsolae.com 12 Lavender SI Revision0 $ 978 809.8316 info@�nvaleontech.com Noll,AnMA Ot6AS Sheet t of 2