Loading...
HomeMy WebLinkAboutPlans - 45 BRIDGES LANE 6/16/2016 ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3, A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWRE BRANCH CIRCUIT WLL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. 1 CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(6). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING P01 POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED NTH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PVI COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES cif heets Attached GRAM GEN #168572 1. ALL WORK TO BE DONE TO THE 8TH EDITION ELEC 1136 MR OF THE MA STATE BUILDING CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE INCLUDING MASSACHUSETTS AMENDMENTS. MODULE GROUNDING METHOD: ZEP SOLAR AHJ: North Andover REV BY DATE COMMENTS REY A NAME DATE COMMENTS UTILITY: National Grid USA (Massachusetts Electric) PREMISE OWNER DESCRIPTION: DESItXt: CONTAINED L-THE T BE USED F HEREIN .qB NUM�A: JB—M3884 00 CONTAINED SHALL NOTBE USED FOR THE MIKE FOX Mike Fox RESIDENCE George Puckett . SolarCity REHEAT Of ANYONE EXCEPT SOtARClTY INC.. MOUNTING S1SlEi: 1'�„c NOR SHALE IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 W Flashing—Insert 45 BRIDGES LN 11.96 KW PV ARRAY PART TO OTHERS E WTSIDE THE RECIPIENTS MODULES: NORTH ANDOVER, MA 01845 ORGANIZATION,IXCEPT IN CONNECTION'MIH THE SALE AND USE OF THE RESPECTIVE (46) TRINA SOLAR #TSM-260PDO5.18 24 6t.Mmiin Drive,Buil&1 2 Unit/1 SO ARCITY EQUIPMENT,WITHOUT THE WRITTEN INVERTER. PAGE NAME: SHEET: RET: DATE: L(650)638-1028�FA(650)63B-1929 PERMISSION Or SOLARCITY INC SOLAREDGE SE1000OA—USOOOSNR2 COVER SHEET PV 1 6/14/2016 (BBB)-sa-aTY(765-2469) ww.eo!arcltyaan PITCH:32 ARRAY PITCH:32 MP1 AZIMUTH:201 ARRAY AZIMUTH:201 MATERIAL:Comp Shingle STORY:2 Stories PITCH:32 ARRAY PITCH:32 MP2 AZIMUTH:111 ARRAY AZIMUTH:m MATERIAL:Comp Shingle STORY:2 Stories r t._ PITCH:32 ARRAY PITCH:32 MP3 AZIMUTH:21 ARRAY AZIMUTH:21 a JASON WILLIAMMATERIAL:Comp Shingle STORY:2 Stories TOMAN s PITCH:32 ARRAY PITCH:32 o STRUCTURAL MP4 AZIMUTH:291 ARRAY AZIMUTH:291 NO.slew 90 9F ���Q MATERIAL:Comp Shingle STORY:2 Stories G1s ER�� /0 Al.EHG 016 Digitally signed by Jason Toman Date:2016.06.1410:35:29-07'00' Pt h 12 3 'n LEGEND CL 0 (E)UTILITY METER & WARNING LABEL e1 O INVERTER W/INTEGRATED DC DISCO m EH B ❑ & WARNING LABELS a (E)DRIVEWAY © DC DISCONNECT&WARNING LABELS In AC DISCONNECT&WARNING LABELS Q DC JUNCTION/COMBINER BOX & LABELS DISTRIBUTION PANEL & LABELS A —„— D , ,- - , C [' ID LOAD CENTER&WARNING LABELS A A O DEDICATED PV SYSTEM METER STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR _ CONDUT RUN ON INTERIOR Front Of House GATE/FENCE O HEAT PRODUCING VENTS ARE RED INTERIOR EQUIPMENT IS DASHED L-J SITE PLAN N 1Scale:1(8”=1' Ar 0 ' 8' 16' W 5 JBQ183884 00 PROMISEOVO: DESCRIPTION: DE9CN: CONFIDENTIAL—THE INFORMATION HEREIN ,OB NUMBER: - CONTAINED SHALL NOT BE USED FOR THE MIKE FOX Mike Fox RESIDENCE George Puckett BENEFITCF ANYONE EXCEPT SOLARCITY INC, MOUNTNC SYSTEM: ®j„ ®lar 't Y NOR SHALL IT BE DISCLOSED IN YrtiOLE CR IN 45 BRIDGES LN 11.96 KIN PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS ZS Comp V4 wFlashing-Insert ORGANIZATION,EXCEPT IN CONNECTION iNiH MODULES NORTH ANDOVER, MA 01845 24 SL MMh Drive.8�P g 2.Wt 11 THE SALE AND USE OF THE RESPECTIVE (46) TRNA SOLAR#TSM-260PD05.18 PAGE NAME: SHEET: REV: DATE: M«Ib«ough,MA 01752 SOLI2CITY EQUIPMENT,WITHOUT THE WRITTEN INVERTER: 1(650)638-1028 F:(650)636-1029 PERMISSIDN OF SOLARCITY INC. SOLAREDGE SE10000A-USOOOSNR2 SITE PLAN PV 2 6/14/2016 (888)-SOL-CITY(765-2489) —.aeaAY— S1 Sl S1 13'-5" 4„ 1- ' (E) W 1- (E) LBW H SIDE VIEW OF MP1 NTS B SIDE VIEW OF MP2 NTS SIDE VIEW OF MP3 NTS _ _ C LANDS APE %S6A4CING X-CANTILEVER 4LEVER Y-SPACING Y-CANTILEVER STAGGERED LANDSCAPE X 564 NOTES ACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES 24" STAGGERED MP3 X-SPACING X-CANTILEVER SPACING Y-CANTILEVER NOTES PORTRAIT 4$" 17" PORTRAIT 4$" 1J" LANDSCAPE 64" 24" STAGGERED ROOF AZI 201 PITCH 32 ROOF AZI Ill PITCH 32 PORTRAIT 4$° 17° RAFTER 2X$@ 16'OC STORIES:2 RAFTER 2X8 @ 16"OC STORIES:2 ROOF AZ I 21 PITCH 32 ARRAY AZI 201 PITCH 32 ARRAY AZ[ 111 PITCH 32 C.J. 2x8 @16"OC Comp Shingle C.J. 2X8 @16"OC Comp Shingle RAFTER 2X8 @ 16"OC ARRAY AZI 21 PITCH 32 STORIES:2 C.I. 2x8 @16"OC Comp Shingle FPV MODULE t f`` ! ( � / 5f16"x1.5" BOLT WITH "'f y 5/16" FLAT WASHER JASONWICLiAM INSTALLATION ORDER g TOMAN a ZEP LEVELING FOOT LOCATE RAFTER, MARK HOLE o STRUCTURAL No.51554 ZEP ARRAY SKIRT (1) LOCATION, AND DRILL PILOT V4- A9o9FGrsTEP���aQ --------- --- --------- ON ------- 02) HOLE. FONAI£NZEP MOUNTING BLOCK ATTACH FLASHING INSERTO016 ZEP FLASHING INSERT (4) MOUNTING BLOCK AND ATTACH (3) TO RAFTER USING LAG SCREW. 13-5 (E)COMP. SHINGLE (1) INJECT SEALANT INTO FLASHING (E) ROOF DECKING (2) (3) INSERT PORT, WHICH SPREADS SEALANT EVENLY OVER THE SIDE VIEW OF MP4 NTS 5/16" DIA STAINLESS LOWEST MODULE SUBSEQUENT MODULES ROOF PENETRATION. t v STEEL LAG SCREW INSTALL LEVELING FOOT ON TOP (2-1/2" EMBED, MIN) {4) OF MOUNTING BLOCK & MP4 X-SPACING X-CANTILEVER Y-SPACING Y-CANTREVER NOTES LANDSCAPE 64" 24" STAGGERED (E)RAFTER SECURELY FASTEN WITH BOLT. PORTRAIT 1 4$" 1 17" STANDOFF RAFTER2X8 @ 16"OC ROOF AZ291 PITCH 32 STORIES:2 ARRAY AZI 291 PITCH 32 $CdIE:11/2"=1' C.J. 2X8 @16"OC Comp Shingle JB-0183884 00 PREMISE Dom DESCRIPTION- DESIGN, CONFIDENTIAL-THE INFORMATION HER -NUMBER: +\��x CONTAINED SHALL NOT BE USED FOR THE MIKE FOX Mike Fox RESIDENCE George Puckett .,,SolarCity. BE NEFlT OF ANYONE EXCEPT SOLARCItt INC., MOUNiWC SYSTEM, �'•..� Nae SHALL IT DE DISCLOSED IN vmaE OR IN ZS Comp V4 w Flashing—Insert 45 BRIDGES LN 11.96 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPiENYS urouLEs: NORTH ANDOVER, MA 01845 ORGANIZATION,EXCEPT IN CONNECTION NTH 24 St.Marts D,1.,Building 2 Unit 11 THE SALE AND USE OF THE RESPECTIVE (46) TRINA SOLAR #TSM-26OPDO5.18 PACE NAME SHEET: REV.. DATE M.,lb-9h,MA 01752 SOLARCITY EQUIPMENT,NSIHWT iNE WRITLEN WNRiER: T:(650)638-/028 F:(650)638-1029 PERMISSION OF sOLARCIn INC "SOL SE1000OA-USOOOSNR2 STRUCTURAL VIEWS PV 3 6/14/2016 (BBB}-sa-CITY(765-2469) wows I—ity— UPLIFT CALCULATIONS SEE SEPARATE PACKET FOR STRUCTURAL CALCULATIONS. CONFIDENTIAL-THE INFORMATION HEREIN WTB NUMBER: PREMSE DONE, OESONP➢ON. DE9E$F JB-0183884 00 ®'a,,, BENEFIT O SNAIL NOT DE USED FOR THE MIKE FOX Mike Fox RESIDENCE George Puckett ®'gr �}a' NOR SH OF ANYONE EXCEPT IN WHOLE INC., MOUNTING SYSTEM, A�,� Q 6�/ NOR SHALL IT 8E DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 45 BRIDGES LN 11.96 KW PV ARRAY PART To TIOTHERS EXCEPT IN THE CONNECTION WITH MODLU& NORTH ANDOVER, MA 01845 IXiGANIZA71ON,EXCEPT IN Ca.'NEC77ON W97H THE SALE AND USE OF THE RESPECTIVE (46) TRINA SOLAR #TSM-260PD05.18 24 St.Mmtb�Drive,Building 2 Unit ii SOLARCITY EQUIPMENT,WITHOUT THE WRITTEN RIVERTEk PAGE NAME: SHEET: REN DATE: Mar8-1028h,MA 650) PERMISSION OF SOLARCITY INC. PV 4 6/14/2016 _.-838-7028 F:(650)636-7028 SOLAREDGE SE10000A—USOOOSNR2 UPLIFT CALCULATIONS (.)-.-CITY —amary— GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND(N)#8 GEC TO TWO(N)GROUND Panel Number:C3030MB1200 Inv 1: DC Ungrounded INV 1-(1)SOLAREDGE @SE1000QA-USOOOSNR LABEL: A -(46)TRINA SOLAR yy TSM-260PDO5.18 GEN#168572 ODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:05033237 Tie-In: Supply Side Connection Inverter; 1OOOOW,240V,97.5%; w�llnifed Disco andZB,RGM,AFCI PV Module; Y60W,236.9W PTC,40MM,Black Frome,H4,ZEP,1000V ELEC 1136 MR Underground Service Entrance INV 2 Voc:38.2 Vpmax: 30.6 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A MAIN SERVICE PANEL E 200A/2P MAIN CIRCUIT BREAKER SolarCity (E)WIRING CUTLER-HAMMER Inverter 1 Disconnect CUTLER-HAMMER 5 A 1 20OA/2P 7 Disconnect 126 SOLAREDGE A B 60A SE10000A-USODOSNR2 DC_ MP1:1x18 C - -"-"'-" A tt 2 8 Lp H MP3,MP4:1x12 (0 LOADS crvD ---- cu° ------------------------- -Fac ---T or. oc, - MP2,MP3:1x16 EC F N D ---j -GND __ Ems_-_ ---______ -___________ __}____ ___EGC _ __________ __ J )Can&K Kit;3/4*EMT EGGLEC i 1 I 1 1 � GEC 1I TO 120/240V 1 SINGLE PHASE I 1 1 UTILITY SERVICE1 I 1 i 1 I I i 1 PHOTO VOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN Voc* = MAX VOC AT MIN TEMP POI (2)Gro%d Roo B (U`UTLER-HAMMER @ DG222NRB A (i)S20.t2 4 S RING dUNCPON BOX 5(o B,Capper Disconnect;60A,240Vac,Fusible,NEMA 3R RC 2x2 S1R GS,UNFUSED,GROUNDED DC -(2}ILSCO!IPC 4(0-@6 1 -(1)CUTL%)rmER 9 DGiWNB �/ insulation Piercing Connector;Main 4/0-4,Tap 6-14 Ground .11.1 t;60-100A.GmwW Duty(DG) P V (46)SOLAREDGE 300-2NA4AZS S Powe Box Opt mize,300W,H4,OC to ZEE SUPPLY SIDE CONNECTION.DISCONNECTING MEANS SHAD,BE SUITABLE -(1)CURER-HAMMER @ DS16FK f Gass R Fuse ID (1)AWG @6,Solid Bore Copper AS SERVICE'EQUIPMENT AND SHALL BE RATED PER NEC. -(2)FFit.; SHAWMUT @..TRIIRFI PV BACKFEEO OCP Cid -(1)(round Rod;5/8'x 8',Copper Fuse;60A,250Y,Gass FINS C (1)CDiTLERA ER-HAMME@ DG2220R8 D '(N)ARRAY GROUND PER 690.47(D).NOTE: PER EXCEPTION NO.2,ADDITIONAL R 24GVao,Non-fusible,NEMA 3R -(1)CUI ER-tIAMMER Y DGIODNB ELECTRODE MAY NOT BE REQUIRED DEPENDING ON LOCATION OF(E)ELECTRODE Grwnd ..,rd t;60-IOOA,Generd Duty(DG) rT /6,THWN 2,Black i 1 AWG @6,THWN-2,BI.Ck 1)AWG i8,iHWN 2,Black Voc*=5o0 VDC Isc-30 ADC T r:(2)AWG @IO PV Wire,60DV,Black Voc*=50D VDC Isc=15 ADC O (1)AWL @6,THWN 2,Red i©�(1)AWG @6,1HWN 2,Red I4)107-(7)ANG @8,THYZ Red Vmp =350 VDC Imp= 20.53 ADC 1 I tIv,F(i)AWG @6 S Id Bare Copper EGC V p =350 VDC Imp ADC E`-1-(i)AWG @6 THWN-2,White NEUTRAL Vmp =240 VAC Imp-42 AAC I ���iii(1)AWG @10,THMN-2,White NEUTRAL Vmp =24o VAC Imp=42 AAC �-%LL(IJ AN @10,THHN/THYM-2,Green EGC _`l IJ ())ANT @6.Sdid Bare.Copper,DEC _ -(7)CanOult Kit:3/4"EMT -(1)AWG @8.THWN-2,Gr- EGC/GEC-(1)Conduit Kit; EMT, ��I�(1)ANG i10,THWN-2,Black Voc*=500 VDC Isc=15 ADC E�g��(2)AWG @lO PV NSre,600Y,Black Vac* =500 VCC Isc=15 ADC (1)AWG @10,THWN-2,Red Vmp =350 VDC Imp=13.2 ADC (1)AWG @6,Solid Bore Copper EGC VmP =35o VDC ImP=$.8 ADC j (1)ANG @I0,1HHN/THNN-2,,Grecn,ECC..... _I L=1 j E�(2)AWG 06 PV We,§ 600V,Block Voc* 500 VDC Isc=15 ADC OI (1)AWG @6,Sold Bare Capper EGC Vmp -350 VDC Imp-11.73 ADC LES ...... ...... ...... ..... ..... .. I CONFIDENTIAL-THE INFORMATION HEREIN "NUMBER: JB-0183884 00PREMSE GYM: DESCIMPRWL I DEM. \\` CONTAINED SHALL NOT BE USED FOR THE MIKE FOX Mike Fox RESIDENCE George Puckett �arCi}`` BENEFIT OF ANYONE EXIT SOLARCITY INC., MOtM1iING SYSTEM: J 1.�/ NOR SHALL IT BE DISCLOSED IN MIOLE OR IN 45 BRIDGES LN 11.96 KW PV ARRAY i�ASo PART TO OTHERS OUTSIDE THE RECIPIENTS ZS Comp V4 w Flashing-Insert ORGANIZA110N.EXCEPT IN CONNECnGN WITH MODULES: NORTH ANDOVER, MA 01845 THE SALE AND EXCEPT THE RESPECTIVE (46) TRINA SOLAR #TSM-260PDO5.i8 24 St Moron Dd.,Building 2,Unit 11 SOLARCITY EQUIPMENT,W17HWT THE WRITTEN PAGE NAME: SHEEr: REN DATE: Madbomugh,MA D1752 PERMISSION OF SOLARCITY INC. INVERTER,' T:(650)638-1028 f:(650)638-1029 SOLAREDGE SE1000OA-USOODSNR2 THREE LINE DIAGRAM PV 5 6/14/2016 (6BB)-SOL-GrY(765-2469) wwv.edwdtycam , Label Location: Label Location: i Label Location: Na a (C)(CB) A (AC)(POI) a ® ` (DC)(INV) Per Code: Per Code: Per Code: NEC 690.31.G.3 ° ® NEC 690.17.E °® ® NEC 690.35(F) Label Location: ° ^• • ° ° ° TO BE USED WHEN • ® (DC)(INV) ••o a •®• "a ® a ° ° •' ® INVERTER IS ® Per Code: UNGROUNDED NEC 690.14.C.2 a Label Location: Label(INV)tion: �)• a •® °®'® Per Code: Per Code: a 00 0 • NEC 690.17.4;NEC 690.54 -a • ° NEC 690.53 :a � a ••a a s a •° o Label Location: •- ' ® (DC)(INV) Per Code: ° • NEC 690.5(C) e'• sa a • Label Location: o • •• I,Vd,(,, R� (P01) a ° ° ° ® o ° •' - Per Code: •'• •1' • NEC 690.64.6.4 Labell-ocation: (DC)(CB) Per Code: }, ,',u! !'„yr Label Location: Ills NEC 690.17(4) A ! (D)(POI) ® ® a ! Per Code: NEC 690.64.B.4 tX%)II,yY;1' Label Location: (POI) Per Code: NEC 690.64.B.7 (AC)(POI) Im LabelLocation: •o o (AC):AC Disconnect a o a Per Code: ®® (C):Conduit NEC 690.14.C.2 (CB):Combiner Box (D):Distribution Panel (DC):DC Disconnect (IC):Interior Run Conduit Label Location: (INV):Inverter With Integrated DC Disconnect (AC)(POI) (LC):Load Center •' Per Code: (M):Utility Meter ®-,,, ® ,• NEC 690.54 (POI):Point of Interconnection CONFlDENTIAL–THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR �,.®® ,ass clew—way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC.,NOR SHALL IT BE DISCLOSED a. _ son Nateo,[A 94962 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, a 4t` T:(65U)639-1028 r:(650)638-1029 EXCEPTE R INECRT PATH ER SALE ANO USE OF THE RESPECTIVE Label Set '®® (888)-SOL{ry(765-2489)+wnv. ,dty- SOLARCITY EQUIPMENT,TOTHOUT THE WRITTEN PERMISSION OF SCLARCUY INC. i solar® ® � m solar SolarEdge Power Optimizer L Module Add-On for North America P30C!P350/P400 SolarEdge Power Optimizer Module Add-On For North America IN,ED ILII TV IN,72<eI11V ,f 96 peal,PV m Euler) dales, ,._ modules) P300 1 P350/P400 ® INPUT_ 31NT 310 460ry nra to m rpat ,g I mpx,atprel aR gp P & �< IV I t 111 A& OUTPUT DURING OPERATION(P0wER OPTIMIZER CONNECTEDT00PERATING INVERTER) um 15 Adc OUTP Vda OUTPUT DURING STANDBY OPTIMIZER DISCONNECTED FROM INVERTER OR OFF} � < i .` �t> „`+- Safety OalPut va ege Per - I ..5 STANDARD COMPLIANCE -- -- -- -- MC e, E 3 Safxry... ..- .... fC6210p-11 etY)ULiZi3 _ INSTALLATION SPECIFICATIONS 4 - !�� 111 I� '. (< _a gr!'n s 1 I: ca/a : „ .,_ Outputw ( e<mr pe<hle to d mphenc_-_ c.tPutwre teogm - - os! 12!3.9 �• eznng ;cEsl N. Pelative Hum dty - PV SYSTEM DESIGN USING A SOLAREDGE THREE PHASE THREE PHASE INVERTER SINGLE PHASE _ZpBV _ AMv i PV power optimization at the module-level � M am�m g ergs(�.-,�.opnm srs, e �p >e Up Lois%more energy Maximums gte gr(—"Oen+,e.,) 21 tS so SUPenorefi ncyt995%) Ma..mum ercer5<n E_.. MLUgalesall types of odole mismatch loss s,trPmm fac[urLng[olemnce to Partial shatl ng Para!els g fo ffereet tengs renxanonz. Ye' a Flexlblerystemd gn for maumum pace VHiizahon -F tnstallanan with a single bolt ^Next generation mantenapcetvthm d I level monitoring > -&I,, voltage h.td,..for installer and firefighter safxry _ 4x.r`�.Y t. ras,lC -.av ole _n.�L ..mss eatL. tit t.r..Dare Age uc j I THE`grin-amount AAODULE TSAR-PD05.1 Mono Multi Solutions OIMt'JaIONS ax'tl U.00I I{ fL TRI:41—A III unit:mm Peok Pawer WotisPr.,.=jWp) 250 235 250 265 9Ai P O tR ti I P •('.J) 0-+3 THE � �( Pa V It fl V {VI 30.3 30S 306 30-8 l a m Povre (AlC rent luta T� �_ Op C uif Volt g vcc iV) 38.0 38.1 382 383 amount Sh tC it CVrtenf-Izc(A) 8.]4 8.88 9.00 :9.10 MO D _ Effi y I%) 153 156 13.4 lb2 _ gggggg ! Max mem Power-Pe.�=IWp) 186 190 i93 19? 60 �� � I FAaxrmum Power Voltage-V..r IVI 28.0 .28.1 25.3 28.d 1 _ _ Maximum Powsr Current i..vv(A) 6.b5 b.J4 6.84 b43 MULTICRYSTALLINE MODULE PCO5.18 n n op c it vintage(v)-v«1vj 35.z -A 354 ass WITH TRINAMOUNT�FRAME j Sh.1t Ci...tt CPaem(A)k,(A) zm Zv 227 Jas slz is.� oo.�.wa n.Amee-,Temp aiJre2�.w Pe_y mr_ 250-265W IAM1ANIC,A1,DATA — POWEROUTPUTRANGE soler tens Mmr=rvJlmme isb+ub mm tb h,ene:) Cellatlenfoioa so-11s{6+lot . Fast and simple to install through drop in mouni;ng solution (�,- Modale d men�ions lbso k 442 x Aomm l6 vs 39os ts]In�hesl im fir`1 Weight 19.6 kg(431216) 16.27o .--_._ --.--- - ----_ n Gass 32m 0.13 ill hsi).Hgh. nmr on AR Coaietl Tem Pered Gla s. MAXIMUM EFFICIENCY —1?� Baakshsef wha Erame Block d dAl i mAlioy Good aesthe 1cs for residential applications I eox IP 65 !P] f d Cobies Pb—r T h I Oy cpbbe d 0mm'(0-6 inches'), 1200 (72 h_z) POSITIVE POWER TOLERANCE >., 1 cveves aPP �.:aouLE(2�o'k�} connecror H4—ph.— F! 4AmphenolFre TV, JL I703 GA,2 for Salol City �— Highly r llable due to stringent quality con+5 I ss)J4 T_k( Ir i< i�,rEx'RiJAE RATING-5� �_� tv<AXI`AU+4PA`I`JCS V�� Operafln9 Cell -C j-2-C) OPerahoua'iemPeralue -d0-+83°C P = u - ' '<} Temperature iNOCt) .Maximum System IOOOV DOOEC) t J - .sa: temDeraiure COEfflClent of P=w -O.AI%/'C Voltage tOWV DC{Ut) 1-r ', ) - ,1- , Temperafune Coeffic enf o(Voc -0.32%PC Max Serres Wse Rati 9 13A 1 •.2 � ., �s T P I C f!i I fi« 005%/C ------ --- m - .-. i ti i d is withstand caollenging=;'nvironr�ar�ol t tJ Pl d!IO IS �=w3.rv0 -.SIE 54)O P rin— l0 ysar Product Norkmanshp Narraniy CERT-ICr;t=aN ' 1 l I - 25 ysarl nearP 1 M da F .._ -_- —.a LINEAR PERFORMANCE WARRANTY v AGIt,G ,,Rt,G4 rwr= `r v2 ry-} 05 Y11,rine.,P—Di\'tlarrQnP co:•w, Motlutes Per box:2b Pieces z 5 na Solor L;ri lcc Modules Der 40'conte net:I28 Diecez - ka t 1 r r Asoro+a D�y�elee bnex ,b�er=eo o , S'p Y I�YR, solar® Single Phase Inverters for worth America solar® z SF300OA-US(SE380OA-US1 SE5000A-US(SE600DA-US( SE7600A-USj SEi0000A-USI SE11400A-US SE3000A US SE3800A US SE5000A US SE6000A-US SE]6000.US SE10000A US-Sf11900A US SolarEdge Single Phase Inverters ® OUTPUT - - - Nam nal AC oweronR„t 3D00 3sG0 SOee9s80@208V - 31400 _ 6CC0 J6� VA .. COLO @2301 Max.ACPov.er Ovtput - 3300 - 4150 5450(>24GV F.. 8350 10950@2-001 12000 vA For North America ACOu[ ge Min:N r h"ax' _ ✓ j SE3000A-US J SE380OA-US J SE500OA-US!SE6000A-US( &3 a°a 22v 1 AC OotF V g Min:Nam Max J f f f ✓ f SE760OA-US J SE10000A-US J SE1140OA-US 'r 1-2a 264vas dC freq yh+n.-Nem.,Max' _ 593 6G ' -605( hHi ceurttry zeteng ST-60-605) Hz_ " - -- . c Na�00 os Ouvoo,4,rzent Si5 21 32 @ 47,5 A GFDITh Id -.- - -. - 1... - - 081 L 16 2 IIV i z4ov i a2 >aov A �; t un itvA t g shndng on,.nu ryCcnfigarabeT resholds - Yes - - - „ INPUT vert < M mu - _ DCP (STI 4050 s100 6750 S1G0 10250 131rc 15350 w W2n T sfe, J g nded Yes M In V __ 500 Vdc �, - N m OC 325 C 208V/ESQ @ 240V I Vdc 33 varJ - 8 34 5 All -- M=x Input Nran[ 4 5 13 165 12I@ 2081 1 23 k @ 2 - 1s5@zaov 30sp z4Gv i' �IV M nP 5h tC C _ _ 45_ - -. ..Ad, c yx • I III J Re"­P Ly--n— ­­d f I, yy I I Y _ l 1 6 d F i t 1 D _ FAOkrtSens�tlmq - I _ I inn .r Mawmu rtific en y 9]] 9F,2 983- 18 98 98 ` cEc We gi Lifid , 92 5 98 -4?5 @—v4]S nJ 5 I-9d @ 2081 97,1 --% - y;240V 9J5@ Z40V_. ., V ghttim I.— ADDITIONAL ADDITIONAL FEATURES "� '� y� Support cerfaces RS485,0.5232 Eh e,2 6800(oRt'onail- _ — ' ReveFe bade Data,ANSI 1 IOp¢on,Y- Rand Sh d NEC 201369012 fun h Ued h SokrEd _ ailed•' Y _ ger pd h tdo„nkc III STANDARD COMPLIANCE 5 r - -. UL-741,UL 6998 UL1998 CS,222 G dCo on Scanaards IEEE35.2 INSTALLATION SPECIFICATIONS AC IP d t 6 xAnge f /_366 ALVG _ 3jG m(83AWG nu d lit f1IFs 374 mll2A Rgsf AWG—g,g DI wth.a(ety 1,,,.hch 30 5 121 105( n( � 305212 5x]2(715 z315v 184 __ 2;5a 315 L315 x260 ih mm ' We&ht SafctY 9wtch 512 j232 _ 54Ij241 - SC 41401 I6(kg._. Ccol;ng Na[urai Conve<Ton M:111-1 Fans(use replacea6ie) fan(us the best choice for 5olarEt L enabled*terris Noise c <5G --- deA - Integratedarcfaultprotection(Type 1)for NEC201ifiMll compliance Min:%I p'—,g emPerawre j 13 m+140(zs to+6o(�40 co+ .e,on ava'IaBie`q 'F 'C Superior efficiency(98%) Nange. ._ ..__._ P cti h g 11 IS Small,hghtwelghtandeasytoiastallon provided bracket _._._ ___.. __....... Built-in module-level monitoring .,wrsriuoaeso s,. a Internet connection through:Ethernet or Wireless Outdoor and indoor installation Fixed voltage inverter,DC/AC conversion only - Pre-assembled Safety Switch for faster installation Optional-revenue grade data,ANSI C12.1 USA-GERh9ANY-ITALY-FRAME-!APAN-CHINA-AUSTRALIA-I UL N[IHERLANDS-tSRM. wwL4.solaredge.US ,'SOIarCity I ®pSOtar Next-Level PV Mounting Technology ,;^SOIarClty Z pSotar Next-Level PV Mounting Technology Components Z$ C0111p l for composition shingle roofs Mounting Block Array Skirt Interlock Pad No.850.1633 ! Part No.850-1608 or 500-0113 Part No.850-1308 or 850-1613 Whallo UL2703 Listed to UL 2703 Usted to UL 2703 AD op 7 b Flashing Insert Grip Ground Zap V2 Pad No.85-1628 Pad Ivo.850-1606.,850-1421 Part No.85p1511 Listed to UL 2703 Listed to UL 2703 Listed to UL 467 and UL 2703 OMPq aF Description PV mounting solution for composition shingle roofs Jog W / Works with all Zep Compatible Modules �'oancn o" Auto bonding UL-listed hardware creates structural and electrical bond • ZS Comp has a UL 1703 Class"A"Fire Rating when installed using modules from any manufacturer certified as'Type V or'Type 2' Captured Washer Lag End Cap I DC Wire Clip U` LISTED Pad Na 850.1631-001 Pad No. Pad No,850-1509 Specifications 850-1631-002 iL)8%1586Or85P1460 1 Lisledto UL 1565 850-1531-003 (R)8561588 m 850-1467 ' • Designed for pitched roofs 850-1631-004 • Installs in portrait and landscape orientations ZS Comp supports module wind uplift and snow load pressures to 50 per per UL 2703 Wind tunnel report to ASCE 7-05 and 7-10 standards ZS Comp grounding products are UL listed to UL 2703 and UL 467 ZS Comp bonding products are UL listed to UL 2703 Engineered for spans up to 72'and cantilevers up to 24' Zap wire management products listed to UL 1565 for wire positioning devices I Leveling Foot Pad No.8561397 Zepsolar.com zepsolaccom Listed to UL 2703 This tlocumentdoes"t—a anyexpress__,,Y by zap So:arorebaut its products orserwcas.It,Solar s Wewarranty is contained In Ne wdtten product warranty for Thts documantdoes notcreale anyexptess—hroy by Zep Soar or about its pho lu or servues.Zep SOlarss01ewarrah,is coma-4 in the written productwarraniyfor eat product.The ehtl-user dorumentatlan stippetl cath Zep SOlarsp.duds--uhtes the sole spetif aims mr—irW,the product 11—et.Mecnehaner's solely earn Prado.Thnd d—ehasm shipped with Zep SOlars produtta iwn ah eNe sale speufrcanast rerened io m the duct wa proty,Th—1-1 is-1y respenshla for verity rg the su laNlb Of ZepSWarspreducts tOr each use.Speribcafans are subjeC.lo mange wilhaut notice.Patents and Apps:zsjsit, responsiblefwv.:(ying ma.utatinyor ZepS0ei`e productsrareach use_Speafcal ons are subject la Mange vgNoul noaca.Patens and App p srnn. OOcument#500-1839-001 Rev D Data last exported:AP1129,Into 11:21 AM Docume1t#800-1839001 Neap Date last exocrted:Aphl 29,20161/22 AM