HomeMy WebLinkAboutCertificate of Compliance - 99 RALEIGH TAVERN LANE 12/9/2004 Town of North Andover Q NORTN ,
Office of the Health Department
Community Development and Services Division
v ; a
400 OSGOOD STREET
North Andover, Massachusetts 01845 s"""° �g
1 SACHU S�
Susan Y. Sawyer, REHS/RS 978.688.9540-Phone
Public Health Director 978.688.9542-Fax
cIFRTIFIC TE OF CO�V1'1'.GJ--/ IL
As of:
(December 9, 2004
This is to certify that
the individuafsu6surface disposafsystem
repaired FuffSystem
by
James Xellett
at
99 Raleigh Tavern .cane
North Andover, W,4 01845
has been instaffed in accordance with the provisions of Title V of the State Sanitary Code and
with the,North Andover 0oard of I feafth regulations.
7(ie Issuance of this certificate shaff not be construed as a guarantee that the system wiff
function satisfactori(y.
Susan T Sawyer
Tu6fic Yfeafth Director
130ARD OF APPEALS 688-9541 BUILDIN6 688-9545 CONSERVATION 688-9530 HEALTH 688-9540 PLANNING 689-9535
TO F NORTH ANDOVE It.SEWAGE' DISPOSAL SYSTEM
INSTALLATION CI•;T,tTII''ICATION
The undersigned hereby certify that the Sewage Disposal System( )constructed;
(�repaired;
by
.located at
was installed in conformance with the North Andover Board of Health approved plan,
System Design Permit.# ,plan dated with a design flow
of gallons per day. The materials used were in conformance with those specified
crri the approved plan;the system was-'installed in accordance with.tlie provisions of 310
:CI IR.15.000,Title 5 and local regulations,.and the final grading agrees substantially with
the.approved plan. All work is,accurately-represented on the As-built which has been
submitted to the Board of Health..
'Bed inspecttion date:
Engineer Representative
Final inspection date:
Engineer Representative
Installer:
Date:
,,.
Engineer: g ppg ~� Date:
0.�
qq yPY77PH¢ 7,PM pI d,
.
""" .....o _............... ....... —.... ,__..— ............ ... . ......_ �.� ..�o..._� ...................
�_
f> NEW ENGLAND ENGINEEF'�ING SERVICES
,_... ....... INC ... . .... . -d.. . -
October 15, 2004
�� t..
Susan Sawyer
North Andover Board of Health
27 Charles Street OU. 2 0 ?(,)o4
North Andover, MA 01845ra�w
Re; 99 Raleigh Tavern Lane,North Andover
Septic System As-Built
Dear Susan,
The following Septic As-Built plans for the above referenced property are being
submitted for approval and issuance of Certificate of Compliance.
Enclosed are the following:
1. (3) Copies of the Septic System As-Built Plan.
2. (1) Form 3A—Certificate of Compliance Form.
If you have any comments or questions please do not hesitate to contact this office.
Sincerely,
";r,4�/"_*
Steven E. Pouliot
Project Manager
60 BEECHWWOOD DRIVE-NORTH ANDOVER, MA 01845,-(976)686-1766-(888):359-7645- FAX(976)685-1099
TOWN OF NORTH ANDOVER
Office of COMMUNrrV DFVE1,0PM,EN[' AND SERVICES
HEALM11 DEPAR rrMENT
27 CTIARLES STREE'r 41
NORT11 ANDOVER, MASSACHUSETTS 01845 cmu
ccsan Y. Sawyer, IZE14S/RS 978,688,9540.....Phone
PUb is Health Director 9M688.9542 FAX
SEPTIC I NOTES
ADDRESS: 99 Raleigh Tavern Lane MAP: 107.A LOT: 115
INSTALLER: James Kellett
DESIGNER: NEES
PLAN DATE: August 20, 2004
BOH APPROVAL DATE ON PLAN: September 28, 2004
DATE OF BED BOTTOM INSPECTION: September 29, 2004
DATE OF FINAL CONSTRUCTION INSPECTION:
DATE OF FINAL GRADE INSPECTION:
SELECT SYSTEM TYPE
GRAVITY DISTRIBUTION
PRESSURE DISTRIBUTION
PRESSURE DOSING
HOLDING TANK
ADVANCED TREATMENT
OTHER
COMPONENT SUMMARY FROM PLAN
GALLON TANK =
LOADING OF SEPTIC TANK
GALLON PUMP CHAMBER =
LOADING OF PUMP CHAMBER =
TYPE OF SAS
DIMENSIONS AND DETAILS OF SAS:
SITE CONDITIONS
® Existing septic tank properly abandoned
® Internal plumbing all to one building sewer
El Topography not appreciably altered
Comments:
Page 1 of 1
TOWN OF NORTH ANDOVER PVT I
Office of COMMUNITY DEVELOPMEN"I"' AND SERVICES
FlEA1,111 DEPARI'MFIN'T
27 CHARLES STREET
NORTH ANDOVER, MASSACHUSETTS 01845
Susan Y. Sawyer, REIIS/RS 978.688.9540 Phone
Public I lealth Director 97&6W9542 -FAX
SEPTIC TANK
❑ Bottom of tank hole has 6" stone base
El Weep hole plugged
El gallon tank has been installed
(H-10 or H-20) (monolithic or 2 piece)
❑ Water tightness of tank has been achieved
(Visual or Vacuum Test or Water held for 24hrs)
❑ Inlet tee installed, under access port
El Outlet tee (gas baffle or effluent filter) installed, under
access port
El inch cover to within 6" of final grade installed over
one access port, must be over outlet of tank if effluent
filter is present
❑ Hydraulic cement around inlet & outlet
Comments:
PUMP CHAMBER
❑ Bottom of tank hole has 6" stone base
❑ Weep hole plugged
gallon Pump Chamber installed
(H-10 or H-20) (monolithic or 2 piece)
❑ Inlet tee installed, under access port
❑ Pump(s) installed on stable base
El Alarm float working
❑ Pump On/Off float working
❑ Drain hole in pressure line
❑ inch cover to within 6" of final grade installed over
one access port
Water tightness of tank has been achieved
Visual or Vacuum Test or Water held for 24 hrs
Hydraulic cement around inlet & outlet
Comments:
Page 2 of 2
TOWN OF'NORT11 ANDOVER
Offic( of COMMUNITV DEVELOPMEN'r AND SERVIC'ES
1-WAIJ11 DEPAR,rME'N'T'
27 Cf IARLES STREET
NORTH ANDOVER, MASSACHUSETTS 01845
SLIsan Y. Sawyer, REIIS/RS 97&688.9540 Phone
Public Health Director 978.688.9542 FAX
D- OX
❑ Installed on stable stone base
❑ Inlet tee (if pumped or >0.08'/foot)
1:1 Hydraulic cement around inlet & outlets
El Observed even distribution
❑ Speed levelers; provided (not required)
Comments:
SOIL ABSORPTION SYSTEM
Bottom of SAS excavated down to soil layer, as
provided on plan
Size of SAS excavated as per plan
El Title 5 sand installed, if specified on plan
El 3/4-1 Y2" double washed stone installed
❑ 1/8-1/2" (peastone) double washed stone installed
❑ laterals installed and ends connected to header (and
vented if impervious material above)
El Orifices @ 5 & 7 o'clock positions
❑ Gravelless disposal systems: type, number and
location as per plan
El Elevations of laterals installed as on approved plan
El 40 Mil HDPE barrier installed
❑ Retaining wall (boulder/ concrete /timber/ block)
❑ Final cover as per plan
Comments:
PRESSURE DISTRIBUTION
❑ inch manifold
❑ laterals installed with end sweeps
size:
material:
❑ Squirt test ft in height
❑ Equal distribution to all laterals
❑ orifice size inch as per plan
Comments:
Page 3 of 3
TOWN OF NOR'm ANDOVER 00NI,#1
'r, 7.
Office of COMMUNITY DEVEI,OPMEN,r AND SERVICES
HE.AIJH DEPAR'rMENT'
27 Cl IAR[XiS STR EIET 14
NORTH ANDOVI-,"R, MASSACHUSETTS 01845
Susan Y. Sawyer, REHS/RS 978k88.9540 Phone
Public Health Director 978.688,9542 FAX
CONTROLPANEL
13 Alarm & Pump are on separate circuits
El Alarm sounds when float is tripped
El Location of control panel:
Rated for exterior if placed outside
Comments:
SYSTEM ELEVATIONS
Benchmark:
Rod at Benchmark:
Height of Instrument:
INVERT ON DESIGN PLAN ELEV TOP OF PIPE INVERT ELEVATION
Building Sewer OUT
Septic Tank IN
Septic Tank OUT
Pump Chamber IN
Pump Chamber OUT
Distribution Box IN
D-Box OUT Manifold
Lateral 1 HIGH
Lateral 1 LOW
Lateral 2 HIGH
Lateral 2 LOW
Lateral 3 HIGH
Lateral 3 LOW
Lateral 4 HIGH
Lateral 4 LOW
Lateral 5 HIGH
Lateral 5 LOW
Page 4 of 4
TOWN OFN(fffll A114DOVEIZ
Office o1'C0MMt.JN#TY DfiI/ELOIINIEINTAND 811RV'K1,S
0
14EAi-,,rH DEPAR'TMENT'
27 CHARLF'S STREET
NORTH ANDOVER, MASSA011.3SETTS 01845 Ss
Susan Y. Sawyer, REJ IS/RS 978,688.95,10 Phone
Public Health Director
❑D-BOX
Installed on stable
El Inlet tee (if pumpe, .............. C/o-q
❑ Hydraulic cement ;
❑ Observed even di<1
El Speed levelers pr( 1!3 <'
o
Comments:
SOIL ABSORPTION SYSTEM,
N
Bottom of SAS ex
provided on plan
Size of SAS excavated as per plan
❑ Title 5 sand installed, if specified on plan
❑ 3/4-1 Y2" double washed stone installed
❑ 1/8-1/2" (peastone) double washed stone installed
El laterals installed and ends connected to header (and
vented if impervious material above)
❑ Orifices @ 5 & 7 o'clock positions
❑ Gravelless disposal systems: type, number and
location as per plan
❑ Elevations of laterals installed as on approved plan
❑ 40 Mil HDPE barrier installed
❑ Retaining wall (boulder/ concrete /timber/ block)
❑ Final cover as per plan
Comments:
PRESSURE DISTRIBUTION
❑ inch manifold
El laterals installed with end sweeps
size:
material:
❑ Squirt test ft in height
❑ Equal distribution to all laterals
❑ orifice size inch as per plan ,
Comments:
Page 3 of 4