HomeMy WebLinkAboutCertificate of Compliance - 337 SUMMER STREET 7/14/2016 ® S�T'SLED76g6 O 0 e PUBLIC HEALTH DEPARTMENT Town of North Andover Community Development Division CURVTIFICATE COMPLIANCE As of: 7/14/16 This is to certify that the individual subsurface disposal system received a SATISFACTORY INSPECTION of the: Repair of D-box and outlet tee By: Todd Bateson Ate 337 Summer Street Map 107.A Lot 0173 Ve ,Th Issuance of this �' i�at N�rth not be construed as a guarantee that the system will function satisfactorily. - g Y Y icliele Grant Public Health Agent 1600 Osgood Street,North Andover,Massachusetts 01845 Phone 978.688.9540 Fax 978.688.8476 Web www.townofnorthandover.com North Andover Health Department Community and Economic Development Division ON ITE WASTEWATER SYSTEM CONSTRUCTION NOTES LOCATION INFORMATION ADDRESS: 337 Summer St. MAP: 107.A LOT: 0173 INSTALLER: Todd Bateson DESIGNER: PLAN DATE: BOH APPROVAL DATE ON PLAN: INSPECTIONS D-box and outlet tee INSPECTION: ll ll(-v DATE OF BED BOTTOM INSPECTION: DATE OF FINAL CONSTRUCTION INSPECTION: DATE OF FINAL GRADE INSPECTION: SITE CONDITIONS ❑ Contractor reports any changes to design plan ❑ Existing septic tank properly abandoned ❑ Internal plumbing all to one building sewer ❑ Topography not appreciably altered Comments: SEPTIC TANK ❑ Building sewer in continuous grade, on compacted firm base ❑ Cleanouts per plan ❑ Bottom of tank hole has 6" stone base ❑ Weep hole plugged ❑ 1500 gallon tank has been installed H-10 loading ❑ Monolithic tank construction ❑ Water tightness of tank has been achieved by visual testing ❑ Inlet tee installed, centered under access port ❑ Outlet tee installed, centered under access port (gas baffle/effluent filter) ❑ inch cover to within 6" of finish grade installed over one access port ❑ Hydraulic cement around inlet & outlet Comments: PUMP CHAMBER ❑ Bottom of tank hole has 6" stone base ❑ Weep hole plugged ❑ 1500 gallon Pump Chamber installed ❑ H-10 loading ❑ Monolithic tank construction ❑ Inlet tee installed, centered under access port ❑ Pump(s) installed on stable base ❑ Alarm float working ❑ Pump On/Off floats working ❑ Separate on/off floats ❑ Drain hole in pressure line ❑ cover at final grade installed over pump access port ❑ Watertightness of tank has been achieved by testing ❑ Hydraulic cement around inlet & outlet Comments: CONTROLPANEL ❑ Alarm & Pump are on separate circuits ❑ Alarm sounds when float is tripped ❑ Location of control panel: basement ❑ Alarm signal located inside: basement Comments: DISTRIBUTION-BOX Installed on stable stone base /H-20 D-Box Inlet tee (if pumped or >0.08'/foot) Hydraulic cement around inlet & outlets Observed even distribution Speed levelers provided (not required) ❑ Schedule 40 PVC Pipe Comments: