HomeMy WebLinkAboutCorrespondence - 67 VEST WAY 10/4/1999 Town of North Andover TH q Oo`tt t° � FFICE OF •°��°c COMMUNITY DEVELOPMENT AND SERVICES 27 Charles Street North Andover, Massachusetts 01 845 WILLIAM J. SCOTT SACHUs Director (978)688-9531 Fax(978)688-9542 October 4, 1999 William Dufresne Merrimack Engineering 66 Park Street Andover, MA 01810 RE: 67 Vest Way, North Andover Dear Mr. Dufresne: This is to inform you that the proposed plans for the repair of the septic system located at 67 Vest Way,North Andover, have deficiencies which must be addressed before plans can be approved. These deficiencies are as follows: 1. A geo-membrane has been proposed instead of a poured concrete retaining wall. (NA 9.02) 2. Missing statement that existing septic tank must be excavated and removed from the site. (3 10 CUR 15.354(3)(c)) Please be advised that all plan resubmittals require a $60.00 fee. If you have any questions, feel free to contact the Health Department at 978-688-9540. Sincerely, Sandra Starr,R.S. Health Administrator Cc: J. Pallone File BOARD OF APPEALS 688-9541 BUILDING 688-9545 CONSERVATION 688-9530 HEALTH 688-9540 PLANNING 688-9535 Sep-29-99 07: 58A Paul D. Tut-bide, PE/PLS 508-465-0313 P . 02 September 29, 1999 Sandra Starr North Andover Board of Health Administrator Office of Community Development and Services 30 School St, North Andover, MA 01 845 RE: Title V review for 67 Vest Road Dear Sandra, I find that the design plans dated Sept 16, 1999 adequately address the regulations. However, I make the following minor comments and corrections that should be made. ❑ An impervious barrier of geo-membrane is proposed. The North Andover regulations could be interpreted as requiring a concrete retaining wall. If this were so,then the proposed impervious barrier would require a local variance. I find that the use of the geo-membrane should be adequate for this design. ❑ There should be a statement that the existing septic tank must be excavated and removed from the site. 310 CMR 15.354(3)(c) If you have any questions or comments please feel free to contact me. Sincerely Carlton A. Brown, PE/PLS Vest67,doc Ilk ENGINEERING Civil Engineers& Land Surveyors One Harris Street Newburyport,MA 01950 (978)465-8594 LOCATION: NEW PLANS: $125.00/Plan REVISED PLAN'S: YES $ 60.00/Plan SITE EVALUATION FORMS INCLUDED: NO :DATE: -j DESIGN ENGINEER: DATE TO CONSULTANT: *If you want your plans expedited, please submit four plans and included a stamped envelope with the correct amount of postage to mail plans to Fort Engineering. When the submission is all in place, route to the Health Secretary. n� a FORM - U - LOT RELEASE FORM INSTRUCTIONS: This form is used to verify that all-necessary approval/permits from Boards and Departments having jurisdiction have been obtained. This does not relieve the applicant and or landowner from compliance with any applicable requirements. ...........................................0 .0x0.0 0 a a N M a......N f...R 0 0 E N■■ APPLICANT PHONE r ' i /01 ASSESSORS MAP NUMBER 10q- LOT NUMBER o i L 2- SUBDIVISION-/ LOT NUMBER STREET STREET NUMBER OFFICIAL USE ONLY RECOMNIENDATIONS OF TOWN AGENTS DATE APPROVED CONSERVATION ADMINISTRATOR DATE REJECTED COMMENTS DATE APPROVED R DATE REJECTED CON RENTS DATE APPROVED FOOD INSPECTOR-ggH��EA��LTH DATE REJECTED DATE APPROVED SEPTIC INSPECTOR-HEALTH DATE REJECTED COMMENTS PUBLIC WORKS—SEWER/WATER CONNECTIONS A04 7—?Y,—vD DRIVEWAY PERNUT N T� Z G� DATE APPROVED FIRE DEPARTSWW DATE REJECTED COMN ENTS RECEIVED BY BUILDING INSPECTOR DATE 00 c'n rd 6 6 1 ' �` btJ N cOG W 'a W ✓ HQ� � ', '� L Q Q R�7 y � � � C Q r/7 C/J W o W W a a L 0 ° y q ` N bn y G an ° d c. W M4 Gam., aJ ..0 y Y O 0 bn W w 'O 4 ,� O k .may.. - ,b ej y t4 N bn b to ro y L4 0 yy .�G O. y .b y aR7i hdJ �i N 0 o ° n N y 3 3 ° y ra bn ti °d Op c y o c 4-, � in c� ° 0 0.c � .G .� .'� o c � N N u � •° Q N d y CZ y 'a o O•pml N y o cJ o o ay y b 'MpWy,�y •ct �O— 'O n ®�L-+.I I ,NG,' a°, d,b� � :�' � o H y C a C v y ro an.,c °� ic tl .�c ai ,p c bn�q VI 14 ro r. .a aY S o O c no E o S 6 g a vy�n I o c d CN CcC . !z 'E �: N ° V5 F-" U �, bA uWJ Vi I m CJ m ly ON C7 O , y Q tz N v cn pg G7 ,�4 N ca rqa U 0 00 4 p N Ell N N o 1 ti O O oo d Ol r C., bA � >°, o o o` er y bA y bA G G. Q a __ O'O v O •bA G .n` 3 ii C, CL ° ti.� 2y d o 40 0n F atii ti ° G > bA 0 cn > o >,3 ° ti G 0 r- 10 G G i� 0 bA bA;� '+� cu �F5 F' 3 G G U bA p ti bA 7 •_T O U °' ,�•, N G Q U N E ' _ x Y = C, ° O T 3 N ai s 3 K Q c ° w _ 3 v w o G ck w � � o .� 0 a v z0 .� � o'y�i00>A 00 G ° �'u 3 ttf w, �p •G. cd cO G M Q 4. G G A y ) p ❑ v C7 C ti E > o0 0 = Q a' o f o c p a x v E a0i s 0r E E U o` a G 00 b N .� cn rit Uv) 45 UNZ aFw I a� II ! li U Vi 0 a II U C 7 ti ro y Ca 0 0 "? VC:�fj- I )I `T`' AS-BUILT CHECKLIST LOT NUMBER, STREET NAME ASSESSORS MAP& PARCEL NUMBER ✓� LOT LINES & LOCATION OF DWELLINGS LOCATIONS & DIMENSIONS OF SYSTEM, . t ✓ TIES TO LOT LINES & DWELLING, WELLS d, FROM SEPTIC TANK b. FROM LF-AC14 AREA LOCATIONS OF DEEP HOLES & PERC TESTS ELEVATIONS OF DISPOSAL SYSTEM TOP OF FDN ELEVATION LOCATIONS OF WELLS, DRAINS, WATERCOURSES WITHIN 150' OF SYSTEM ✓ LOCATION OF WATER, GAS,ELECTRIC LINES, CABLE DISTANCES FROM CORNERS OF HOUSE TO CENTER OF TANK&D-BOX ORIGINAL STAMP &SIGNATURE ✓ IMPERVIOUS AREAS - DRIVEWAYS, ETC, ~ NORTH ARROW �'"�_ LOCATION&ELEVATIONS OF BENCHMARK USED Town ®f North Andover RTH"' � O tt�eo O OFFICE OF � yt ��o� COMMUNITY DEVELOPMENT AND SERVICES A 27 Charles Street c9A North Andover, Massachusetts 01845 �gssgctHUS�t�y Wn,LIAM J. SCOTT Director (978)688-9531 Fax (978)688-9542 October 20, 1999 Bill Dufresne Merrimack Engineering 66 Park Street Andover, MA 01810 Re: 67 Vest Way Dear Bill: This is to inform you that the proposed septic system plans for the site referenced above have been approved. However, please be aware that a note required on the deed stating that there can be no additional flow to the septic system, ie., no additional rooms, because of the depth to ground water variance.. If you have any questions, please do not hesitate to call the Board of Health Office at 978-688-9540. Sincerely, Sandra Starr, R.S. Health Administrator SS/smc cc: John Pallone File BOARD OF APPEALS 688-9541 BUILDING 688-9545 CONSERVATION 688-9530 HEALTH 688-9540 PLANNING 688-9535 FROM: TO: _Brian_ LaGrasse _ CERTIFIED PUBLIC ACCOUNTANTS North Andover Board of Health 861 TURNPIKE STREET _2 7 :C-h-a-i le s Street NORTH ANDOVER, MA 01845 North Andover, MA 01845 PHONE: (978) 686-7200 FAX: (978) 686-4314 d FOLD —SUBJECT Sediment Analysis DATE August 21, 2003 DPar Br?an-:— As we discussed on the phone, enclosed is the information I received from Greater Lawrence Sanitary District regarding the samples taken from my house. Please call me if you have any questions. SIGNED --------------------- John M. Pallone (0495) (CLICK HERE AND TYPE RETURN ADDRESS) 508 685 7790 r.Udlod 8/18/03 Analysis of material from F.P. Reilly sample dated 8/15/03 The material in question came from the distribution outlet of a failed septic system. The material was diluted with lab pure water and examined with a microscope set at 400x ' phase contrast. The sample contained silica particles (sand), sludge particles, a few pieces of cellulose(plant cells), a few microscopic worms and a large population of bacteria. There is no indication that this material is out of the scope of"normal"septic tank contents. 1 TOTAL P.02 h °o w N N o ® ti k4r) m v O 6 o n ° o r y . r v ° v c, V O v a°i U p O M ° o y°, 21 a °' 04� a y o bA oar o v x a `� o o M ° .�d � w w` O a3i c N � �r a�i O.[—L�� t„ .�J i i'❑�j+ N '° m^ �j cad G y�try•y � �•'•�.�-� � b N 00 " ;, 3 °a o °0 . OD Zvi °o o N ti 002 CID W(A F'+U •� y A Rt b 'Lt an an o C% on U O O o N rn o o R. b w m ° a U Q N [�I N h o w O � w O � N h � o 0 o°g 0 � 00 ig o r A CY/ w^' ii 0 ° U x ti w0 i� x on a"o ° ° 40. ° o 3 w 0o v b ° N 0n o ib �y/ y Cd o ° ° •^j ",a; °� � •r,'y ❑ r OD .0 d A `«' Oho ►� ° 7�, � � ci moo . § ' of o�000000 N ❑�ipv� u: o a� m Boo 0 3 rt- A 00 g Wi 0 v a �a :? , r- HUNz aFW V ti .r7 O O rA w Id V a N A C C C� Cl N Mill. River & Susan meet with Homeowner-John Pallone-Site Review Page 1 of 2 DelleChiaie, Pamela From: Sawyer, Susan Sent: Wednesday, June 15, 2005 11:52 AM To: DelleChiaie, Pamela Subject: FW: Mill River& Susan meet with Homeowner-John Pallone-Site Review Importance: High So Lisa was thinking about this also. It sounds like Dan might be available so can you check with Mr. Pallone. Note that I have a tight schedule since Michele is out so 2-3 is about it for me. Thanks -----Original Message----- From: DelleChiaie, Pamela Sent: Wednesday, June 15, 2005 10:29 AM To: Sawyer, Susan Subject: FW: Mill River &Susan meet with Homeowner-John Pallone-Site Review Importance: High Please advise. Thanks. -----Original Message----- From: Lisa LeVasseur [mailto:lisal @millriverconsulting.com] Sent: Wednesday, June 15, 2005 10:01 AM To: DelleChiaie, Pamela Subject: FW: Mill River & Susan meet with Homeowner-John Pallone-Site Review Importance: High HI Pam, I need to confirm-are we still set for Friday?Thanks, Lisa Lisa LeVasseur- Mill :River Consulting Your C'oniple>te�Souuce,fbr Onsite N'as�tewater ll7unagemerit 2 Blackburn Center Gloucester, MA 01930-2259 978-282-0014 or 1-800-377-3044 fax: 978-282-0012 www.rniIIriverc;onsulti rig,c~or -----Original Message----- From: DelleChiaie, Pamela [mailto:pdellechiaie @townofnorthandover.com] Sent: Wednesday, June 08, 2005 4:02 PM To: Sawyer, Susan; jmp @sp-cpa.com Cc: Daniel Ottenheimer (E-mail); Lisa LeVasseur (E-mail); McBrearty Andrew (E-mail) Subject: Mill River& Susan meet with Homeowner-John Pallone-Site Review Importance: High When: Friday, June 17, 2005 2:30 PM-3:00 PM (GMT-05:00) Eastern Time (US & Canada). Where: 67 Vest Way 6/15/2005 Mill River & Susan meet with Homeowner-John Pallone-Site Review Page 2 of 2 6/8/05 -This is scheduled as a tentative meeting. Mr. Pallone will be away Thursday & Friday, and requested the end of next week for the visit. Please --everyone confirm with me, and we can firm up a date and time. Thanks. Pamela 6/15/2005 Town of North Andover, Massachusetts Form N®.2 f OORTH BOARD OF HEALTH o u0t, f �✓ 19--/ ` L • �° Tl °® DESIGN APPROVAL FOR • 9' 9.1 o'p��p`�,`a 9SSA S 4� SOIL ABSORPTION SEWAGE DISPOSAL SYSTEM VA 6L • f F9 Test No. ' Applicant %, ��f � ., l t � _ �..=-N ' 1 ipr ,:( Site Location f�`� '� ' '� �� Reference Plans and Specs. .<� llad ENGINEER °" IDESIGN �/ D/lTE Permission is granted for an individual soil absorption sewage disposal system to be installed in accordance with regulations of Board of Health. CHAIRMAN,BOARD OF HEALTH Fee—, °fit) �� Site System Permit No. ✓l�