HomeMy WebLinkAboutCertificate of Compliance - 94 SHERWOOD DRIVE 2/11/1998 Form No.4
Town of North Andover, Massachusetts
BOARD OF HEALTH
--Ffebru ary 11 19 98
CERTIFICATE OF COMPLIANCE
This is to certify that
the Individual Soil Absorption Sewage Disposal System constructed (X ) or repaired ( )
by Robert Innes
INSTALLER
at Lot 7 Sherwood Dr
has been installed in accordance with Board f Health Regulations as described in the Design
sign
Approval Site System Permit No. dated— Maw .
19 97
The issuance of this certificate shall not be construed as a guarantee that the system will
function satisfactorily.
BOARD OF HEALTH
e>-
:.A
�t
f:1
J,
SI,
N,
d�'
Town of North Andover, Massachusetts Form No.loll
a
• f 40RTH BOARD OF HEALTH
O t�ao y'�ti
o0
19�`
,o.''t� DISPOSAL WORKS CONSTRUCTION PERMIT
s4CHUSfl
Applicant ,[t-:(L
rvamt ADDRESS TELEPHONE
Site Location
Permission is hereby granted to Construct VI) or Repair ( ) an Individual Soil Absorption
Sewage Disposal System as shown on the Design Approval S.S. No.
CHAIRMAN, BOARD OF HEALTH
Fee 6o D.W.C. No. ��
APPLICATION FOR DISPOSAL WORDS CONSTRUCTION PERMIT
DATE:—(!-// CURRENT INSTALLER'S LICENSE#
LOCATION: a '
LICENSED INSTALLER:
SIGNATURE: (_�, TELEPHONE#.._s'' o Y C
CHECK ONE:
REPAIR: NEW CONSTRUCTION:
IF NEW CONSTUCTION, PLEASE ATTACH FOUNDATION AS-BUILT.
Administrative Use Only
$75.00 Fee Attached? Yes �'° No
Foundation As-Built? Yes No
Approval F � w.�C Date: ,
Town of North Andover f NORTH
OFFICE OF
COMMUNITY DEVELOPMENT SERVICES p
' 146 Main Street
North Andover, Massachusetts 01845
9SSACHUS��
June 10, 1996
Thomas Neve
Neve Associates
447 Old Boston Road
Topsfield, MA 01983
Re: Lot #7 Sherwood Drive
Dear Tom:
This is to inform you that the proposed plans for the site referenced above have been
disapproved for the following reasons:
.Please show 100 feet wetland buffer zone,
Not designed on 165 GPD per bedroom nor 660GPD minimum.
.Tank not 25 feet to foundation.
.No wetlands disclaimer.
No manhole to grade.
.Vent missing.
No elevations for peres.
.Map & parcel missing.
If you have any questions, please do not hesitate to call the Health Office.
Sincerely,
Sandra Starr, R.S.,
Health Administrator
SS/cjp
cc: Bob Janusz
BOARD OF APPEALS 688-9541 BUILDING 688-9545 CONSERVATION 688-9530 HEALTH 688-9540 PLANNING 688-9535
A PLAN REVIEW CHECKLIST
ADDRESS
GENERAL
3 COPIES 4--" STAMP LOCUS NORTH ARROW ' SCALE
&
CONTOURS t-"""�'� PROFILE /�,'�,� SECTION - � �'�BENCHMARK SOIL
PERCS ELEVATIONS WETS . DISCLAIMERS WELLS & WETS '
WATERSHED . DRIVEWAY Elev WATER LINE /,� FDN DRAIN
SCH40 ,,, " TESTS CURRENT? """""` SOIL EVA
SEP'T'IC TANK
MIN 150OG �.-""� . 17 INVERT DROP GARB . GRINDER j (+200% EDF)
25 ' TO CELLAR MANHOLE, -Nr,, ELEV GW # COMPS .
D®BOX
SIZE # LINES G FIRST 2 ' LEVEL STATEMENT
INLET OUTLET / ." _ <.JC) (2" OR . 17 FT) TEE REQ ' D? J�
LEACHING
MIN 660 GPD. ,, RESERVE AREA '' 4 ' FROM PRIMARY? -/-""'
RIMARY'S -/-" 2% SLOPE
2M/IN)
100 ' TO WETLANDS ,--100 ' TO WELLS °"° 4 ' TO S . H.GW �.._. -._.. (�
3 5 TO �
T'ND. INTRCPTR DRAINS '' 325 ' TO SURFACE H2O SUPP 6..°_",._"°_....
.�:
4 ' PERM. SOIL BELOW FACILITY (s.. MIN 12" COVER'1 -1111 FILL?i .X ( 5 '
if above natural elev; 101if below) BREAKOUT MET?
TRENCHES
MIN 660 gpd ,` SLOPE (min . 005 or 6"/100 ' )/-'--' SIDEWALL DIST. 3X EFF.
W OR D (MIN RESERVE BETWEEN TRENCHES . "1-1, IN FILL. r... MUST
BE 10 MIN. 4" PEA STONE? L< (: VENT? ,`,' (>3 ' COVER; LINES >50 ' )
BOT :> + SIDE �� � X LDNG ( = TOT
>�
(L W x #) (DxL t,2)
Copyright a 1995 by 5.t.. Swrr
DATE �� �� Sheet of
BOARD OF HEALTH
TOWN OF NORTH ANDOVER
SUBSURFACE DISPOSAL DESIGN REVIEW
FEE � � PERMIT # C ; DATE RECEIVED
APPLICANT03 JA,vv ASSESSOR' S MAP
ADDRESS PARCEL #
LOT # 7`
STREET DK
ENGINEER /UCUL
ADDRESS
PLAN DATE REVISION DATE
CONDITIONS OF APPROVAL:
APPROVED
DISAPPROVED �/<
D/,) /Cn
/o KL C)% vZs TC� T U
i[4 G-
(f�/U` (j A)G
�J
ltlkp Y- /V CIS b
Town of North Andover NORTH
OFFICE OF 3? 5` o�
COMMUNITY DEVELOPMENT SERVICES p
146 Main Street ' t
North Andover, Massachusetts 01845
SACHU`'
April 17, 1996
Mr. Thomas Neve
Neve Associates
447 Old Boston Road
Topsfield, MA 01983
Re: Lots 3,4,5,7,14,15,16,12,&19 Sherwood Drive
The above named lots at Sherwood Drive have been incompletely submitted. The
submission of new designs after January 1, 1996 requires the inclusion of soil evaluation
forms. Until these forms have been received, the above mentioned plans will not be
considered submitted.
Should you have any questions, please call me at the number below.
Sincerely,
Sandra Starr, R.S.
Health Administrator
SS/cjp
BOARD OF APPEALS 688-9541 BUILDING 688-9545 CONSERVATION 688-9530 HEALTH 688-9540 PLANNING 688-9535
Town ®1 North Andover NORTH
e 9,1Al
,0E
OFFICE OF
COMMUNITY DEVELOPMENT AND SERVICES
146 Main Street
North Andover, Massachusetts 01845
9SSACHUSE�
WILUALM J. SCOTT
r
Director
September 11, 1996
Neve Associates
447 Old Boston Road
Topsfield, MA 01983
Re: Lot# 7,12, 14, 16 Sherwood Drive
Dear Tom:
This is to inform you that the proposed plans for the sites referenced above have been
approved.
If you have any questions, please do not hesitate to call the Board of Health Office at the
number below.
Sincerely,
Sandra Starr, R.S.,
Health Administrator
SS/cjp
cc: Bob Janusz
BOARD OF APPEALS 688-9541 BUILDING 688-9545 CONSERVATION 688-9530 HEALTH 688-9540 PLANNING 688-9535
c�-�/ nz� ev �lev i N/�S
i s 2
FORM U - VERIFICATION FORM Si fJ� KR,P
INSTRUCTIONS: This form is used to verify that all necessary
. approvals/permits from Boards and Departments having jurisdiction
have been obtained. This does not relieve the applicant and/or
landowner from compliance with any applicable local or state law,
regulations or requirements.
****************Applicant fills out this section*****************
APPLICANT: PhoneD�-
LOCATION: Assessor' s Map Number 0 SC Parcel
Subdivision S PtR-ED \Y, Lot(s)
Street cj+ S\-)eP_U_,004Z 19- St. Number q1+
************************Official Use Only************************
ORECOM4ENDATIONS OFTOWN AGENTS:
Date Approved
Conservation Administrator Date Rejected
Comments
Date Approved
Town Planner Date Rejected
Comments
Date Approved
Food Ins ctor-Health Date Rejected
2z��=z
Date Approved
�' c Inspector-Health Date Rejected
Comments
0 -ublic Works - sewer/water connections �� 3 -1 27
driveway permits 3 -42-
Fire Department
Received by Building Inspector Date
REPORT OF SEPTIC TANK FUNCTION
94 SHERWOOD DRIVE,NORTH ANDOVER, MA
11/28/05
INTRODUCTION:
On Thursday November 17,2005 Ms. Judy Hou, 94 Sherwood Drive, North Andover
consulted New England Engineering Set-vices, Inc. regarding the existing condition of the
septic tank located at her house on 94 Sherwood Drive,North Andover. It is her opinion
that something was installed improperly during the construction of the septic system at 94
Sherwood Drive,North Andover, causing frequent clogging of the building sewer pipe
leading from the house to the septic tank(building sewer). The following is a summary of
the events leading up to the November 17, 2005 meeting, as told to Beiliamin C. Osgood,
Jr. by Ms. Hou.
Ms. Hou contends that since she and her family moved in to the home they have had to
have the building sewer cleaned by a sewer cleaning service once or twice per year.
During the latest cleaning the workmen informed her that the pipes into and out of the
septic tank were installed improperly. The pipe entering the tank from the foundation
(inlet) is lower than the pipe exiting the tank (outlet).
Upon learning of this condition Ms. Hou contacted the builder from whom she purchased
the house. It was his contention that since the septic system was installed prior to his
purchasing the partially completed home he was not responsible.
Ms. Hou then contacted the Neve Morin Group. The Neve Morin Group is a group of
engineers, surveyors, environmental consultants and land planners. The Neve Morin
Group (formerly known as Thomas E.Neve Associates, Inc.) designed the septic system
in question and provided an"As-Built"plan to the Town of North Andover, which
certifies that the system was installed properly. The Neve Morin Group investigated the
existing condition of the septic tank and determined that the septic tank,had settled 10
inches on the inlet side of the tank,thus causing the problem. The Neve Morin Group
prepared a plan for the repair of the tank, but has not taken any responsibility for the
problem.
PAGE 2
At the conclusion of the November 17, 2005 meeting between Ms. Hou and Benjamin C.
Osgood,Jr. ,Ms. Hou retained New England Engineering Services, Inc. to review the
current condition of the septic tank and any information available to determine the
validity of the conclusion of the Neve Morin Group.
INVESTIGATION:
Several documents were supplied to New England Engineering Services Inc. by Ms. Hou
which include the following.
1. Plan entitled"plan of land in North Andover, Mass showing"As-Built" Sanitary
Disposal System Lot 7—94 Sherwood Drive prepared for Timberland Builders,
Inc, scale 1"=20', dated May 31, 1997"Prepared by Thomas E.Neve
Associates,Inc. and stamped by John M. Morin.
2. Plan entitled"Plan of land in North Andover,Mass showing"Septic Tank
Replacement" 94 Sherwood Drive prepared for Jian Wen, scale 1"=20', dated
September 14, 2005"Prepared by The Neve-Morin Group and stamped by John
M. Morin.
3. Survey notes dated 6/21/05 entitled 94 Sherwood Drive,North Andover which
were transmitted by facsimile to Ms. Hou on 6/22/05.
The documents supplied by Ms. Hou, as listed above,were reviewed by Benjamin C.
Osgood,Jr. Several inconsistencies were noted which required an on site investigation
that was performed on Saturday November 19, 2005 by Benjamin C. Osgood, Jr. The
septic tank inlet and outlet inspection ports were exposed at the time of the inspection and
additional hand excavation was performed to acquire additional measurements. The
following observations were made.
1. The distance from the sill elevation of the dwelling to the invert of the building
sewer pipe at the inside face of the foundation wall is 24.25 inches.
2. The vertical distance from the top of the septic tank to the top of the building
sewer pipe inlet is 9.5 inches.
3. The vertical distance from the top of the septic tank to the top of the outlet pipe is
6 inches.
4. The water depth in the tank is 54 inches.
5. The points where the pipes protrude from the tank pass through the wall of the
tank via pre cast openings in the tank which are provided by the tank
manufacturer.
PAGE 3
CONCLUSION
Upon review of the documentation and the information obtained from the on site
inspection the following facts can be determined.
1. The invert of the building sewer pipe where it passes through the foundation is 2
inches lower than shown on the as built plan dated May 31, 1997.
2. The invert of the septic tank inlet pipe is 10 inches lower than the invert shown on
the as built plan dated May 31, 1997.
3. The invert of the septic tank outlet pipe is 1/4 inch lower than the invert shown on
the as built plan dated May 31, 1997. (This difference is so small that it would be
considered to be the same.)
4. The septic tank is not level. The inlet side of the tank is 2 inches lower than the
outlet side of the tank.
5. The septic tank inlet pipe enters the septic tank at a point that is lower than the
septic tank outlet pipe in relation to the top of the tank.
What the Neve Morin Group concluded as a result of their investigation is the septic tank
has settled, on the inlet side of the tank only, 10 inches since the time the tank was
installed and their"As-Built"plan was issued. This settlement, in their opinion, had
caused the inlet pipe to the septic tank to be located 6.8 inches feet below the outlet pipe,
causing the frequent clogging.
Based upon the information obtained,New England Engineering has derived a different
conclusion. The fact that the pipe entering the septic tank passes through the tank at a
point which is 3 inches lower in relation to the top of the tank than the pipe exiting the
tank passes through the wall indicates that the septic tank was installed improperly. As
previously mentioned septic tanks are designed with pre-cast holes for installing the inlet
and outlet pipes. These holes are cast in such a manner so that the inlet pipe enters the
tank at an elevation which is 3 inches higher than the outlet pipe. This 3 inch difference is
important because it allows the water to flow by gravity out of the inlet pipe,through the
tank, and out the outlet pipe without clogging or backing up. In this case, at 94 Sherwood
Drive the septic tank inlet pipe was installed in the pre-cast hole which was meant to be
used for the outlet pipe. The outlet pipe was installed in the pre-cast hole which was
meant to be used for the inlet pipe. Simply put, the septic tank was installed backwards.
TAM �
t p
aO lit
g d `Jr� d&' O .0 uiuTt,fuag
pouluzgns �Ijnjpadsmd
•pilenuT osle si uoileoUlpoo sigl`00'51 dWD 0I£glim aouupJ000t,
ui pollt,lsui uaaq lou suq molsks oql oouTS •swojs.�s oildos to uoTlt,llt,lsui aql UIan02
gonlm suoiit,lnSaa aql`0'SI 2Iwo OI£glim omupz000t,m pollulsui uaaq sug TualsAs
agl puu uuld uSisop leutSuo oql jo luoluT uSisop agl of suuoJuoo pap"suoo se uzalsXS
oqi mt,gl saTlii oo goigm lumoluls t, suieluoo ut,ld lltng-sd agl`aiouuagpn3 •,�Indozd
pallelsui put,panouur oq�lut,l oildos aql paimboi aneq pinom put,uoilellelsT walsSs
oildos aql aoj ooueildwoo to oleoi ploo e ponssi aneq lou pinom glit,aH Jo pat,og zanopuV
glioM oql`Alzadoid poliodaa uaaq suoilenala asagl pt,H •apeuz aq of suoiloonoo pazinbaa
ant,q pinogs oqm aaauiSua OmAjpno oql kq pogguopi uaaq aneq pinogs anoge poquosap
put, salt,ioossV anaN,�q pondaad uuld ,fling-sV„oql uo punoj souo agl su gons
soiouedaaosTQ -fltadoid paliodoi lou onm uoilenalo lzanui uoiiupunoj aql put,Tm oildos
agl JO uoilt,nala IaITTi aq 1 •snoauono sT L66I I£ ALM uo salt,ioossd anaN•g seuzogl,Kq
ouop uuld ,fling-sV„all It,gl SuiaaauiSug puujoug mom jo uoiuldo alp sT lT `aaojaaau
•aoglo
oql.To puo ouo of polTTuil oq lou pinom pue Tm oglto spun gloq uo lualsisuoo oq kla}lil
ISOW pinom luauTalllas sigl aanamoq `luauzalllas JOUTM aulos oouauadxo Aum Ii ftliadoid
pollulsui st xuel e 11 •palllas 3TLmi agl/Cja)lrlun st IT `panssl sum uuld llmq se oql uogm
su mou cures all si duel oildos agl jo l.Tanui lallno agl Imp loej aql uodn post,g -adid lallno
all put, adid laiui gill jo suoilt,nala agl to digsuoTlt,laa m uT fiout,dazosTp aaSat,l uana
ue Suisnuo lanai Jo lno sagoui Z si duel oql uollLmlis aql oltyonxa aagl u o L -adid lallno
all anogt, sagoui £ paainboj all jo puolsui adid lallno oql u p zamol sagoui £ Sum goigm
uoTit,nala uu it,pollt,isui sum adid lap oql sT uoilejlt,isuT aadoiduTT sigllo lInsaa aqj
IV F[Dvd
RELEASE AGREEMENT
Property Owners: Jian Wen&Judy Hou of 94 Sherwood Drive, North Andover, MA
Engineers: The Neve-Morin Group, Inc. (Fk/a Thomas E. Neve Associates, Inc.) 447
Old Boston Road, Topsfield, MA
Property: 94 Sherwood Drive,North Andover, MA
Date: eb, <, , 2006
The Property Owners have alleged that certain engineering and surveying work performed by the
Engineers related to the septic system serving the Property was done improperly and negligently
and that, as a result, the Property's Septic System is not functioning properly.
The Engineers deny that their work was improper or negligent or that they are liable in
connection with the Property's septic system.
However, the Engineers and Property Owners have agreed that in consideration of the Engineers
providing certain services, work and materials in connection with a repair of the Property's
septic system, the Property Owners will release the Engineers from all claims and liability.
Accordingly;-the Engineers shall provide the following:
J~ Re-core new invert and outlet locations in existing septic tank and install new inlet aAd
outlet tees with rubber boots, re-plumb effluent line from the existing septic tank to tIe
existing distribution box&re-plumb effluent line from septic tank to dwelling as
necessary. Obtain all applicable approvals from the North Andover Board of Health
(BOH) and provide an as-built plan to the BOH and Property Owners once the work is
completed. Engineers shall be responsible for all fees and costs associated with this
work.
In consideration, the Property Owners hereby release the Engineers, their officers, directors,
agents and employees including, without limitation, Thomas Neve and John Morin, from any and
all causes of action, expressed or implied warranties, damages, contracts, covenants, liability and
claims, of whatever name, kind and nature, both in law and in equity, both common law and
statutory, both state and federal, both known and unknown, which the Property Owners now
have, which accrue in the future, or which they ever had,whether past, present, or future
asserted, including, without limitation, all claims and warranties related to the Property.
The Property Owners acknowledge that in making this release, in which they have had the
opportunity, at all times, to seek counsel of their own choosing, they are relying on their own
judgment, belief and knowledge as to all aspects of any claims; they are acting voluntary and
without coercion or duress; and are not relying upon any representation or statement made by the
parties hereby released.
Witness our hands and seals this day of 920
CAWINDOWSUEMP\Release Agreement.doc
Town of North Andover, Massachusetts Form No.2
a tIORT11 BOARD OF HEALTH
DESIGN APPROVAL FOR
CHUS SOIL ABSORPTION SEWAGE DISPOSAL SYSTEM
Applicant ��'�� Test No.
Site Location
Reference Plans and Specs._ h Q ,9�-
ENGINEER DESIGN DATE
Permission is granted for an individual soil absorption sewage disposal system to be installed
in accordance with regulations of Board of Health.
� 40 /U
CHAIRMAN,BOARD OF HEALTH
LFLec,0, Site System Permit No.