Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Certificate of Compliance - 73 CARLTON LANE 8/9/2016
r - fop • PUBLIC HEALTH DEPARTMENT Town of North Andover Community Development Division CERTIFICATE OF COMPLIANCE As of: 8/9/16 This is to certify that the individual subsurface disposal system received a SATISFACTORY INSPECTION of the: Repair of Outlet tee By: Todd Bateson .At: 73 Carlton Lane Map 106.0 Lot 0020 North Andover, MA 01845 The I 16ance of this certir,,c jte 11 nat be construed as a guarantee that the system will function satisfactorily. M c ele Grant Public Health Agent 1600 Osgood Street,North Andover,Massachusetts 01 B45 Phone 978.688.9540 Fax 978.688.8476 Web www.townofn©rlhandover.com North Andover Health Department Community and Economic Development Division ONSITE WASTEWATER SYSTEM CONSTRUCTION NOTES LOCATION INFORMATION ADDRESS: 73 Carlton Lane MAP: 106.0 LOT: 0020 INSTALLER: Todd Bateson DESIGNER: PLAN DATE: BOH APPROVAL DATE ON PLAN: INSPECTIONS Outlet tee INSPECTION: "t DATE OF BED BOTTOM INSPECTION: DATE OF FINAL CONSTRUCTION INSPECTION: DATE OF FINAL GRADE INSPECTION: SITE CONDITIONS ❑ Contractor reports any changes to design plan ❑ Existing septic tank properly abandoned ❑ Internal plumbing all to one building sewer ❑ Topography not appreciably altered Comments: SEPTIC TANK ❑ Building sewer in continuous grade, on compacted firm base ❑ Cleanouts per plan ❑ Bottom of tank hole has 6" stone base ❑ Weep hole plugged ❑ 1500 gallon tank has been installed H-10 loading ❑ Monolithic tank construction ❑ Watertightness of tank has been achieved by visual testing ❑ Inlet tee installed, centered under access port Outlet tee installed, centered under access port (gas baffle/effluent filter) ❑ inch cover to within 6" of finish grade installed over one access port ❑ Hydraulic cement around inlet & outlet Comments: PUMP CHAMBER ❑ Bottom of tank hole has 6" stone base ❑ Weep hole plugged ❑ 1500 gallon Pump Chamber installed ❑ H-10 loading ❑ Monolithic tank construction ❑ Inlet tee installed, centered under access port ❑ Pump(s) installed on stable base ❑ Alarm float working ❑ Pump On/Off floats working ❑ Separate on/off floats ❑ Drain hole in pressure line ❑ cover at final grade installed over pump access port ❑ Water tightness of tank has been achieved by testing ❑ Hydraulic cement around inlet & outlet Comments: CONTROL PANEL ❑ Alarm & Pump are on separate circuits ❑ Alarm sounds when float is tripped ❑ Location of control panel: basement ❑ Alarm signal located inside: basement Comments: DISTRIBUTION-BOX ❑ Installed on stable stone base ❑ H-20 D-Box ❑ Inlet tee (if pumped or >0.08'/foot) ❑ Hydraulic cement around inlet & outlets ❑ Observed even distribution ❑ Speed levelers provided (not required) ❑ Schedule 40 PVC Pipe Comments: i p