Loading...
HomeMy WebLinkAboutCertificate of Compliance - 236 SUMMER STREET 5/21/2013 � ��y�'Siab jryg4" PUBLIC HEALTH H D PAR 9 R`NT Town of North Andover Community Development Division CERTIFICAT'E OF COMPLIANCE As of: 5/21/2013 This is to certify that the individual subsurface disposal system has been installed in accordance with the provisions of Title 5 of the State Environmental Code: Repair of D-Box By: John Soucy At: 236 Summer Street Map 38 Lot 173 �% orth Andover, MA 01845 T 6, ssua ce of thisccv rt"ic e'shall no be construed as a guarantee that the system will function satisfactorily. 1VI1chele Grant Public Health Agent. I f: COPY 1600 Osgood Street,North Andover,Massachusetts 01845 Phone 978.688.9540 Fox 978.688.8476 Web www.townofnortliandover.com • �'�f.itD��q North Andover Health Department Community Development Division ONSITE WASTEWATER SYSTEM CONSTRUCTION NOTES LOCATION INFORMATION ADDRESS: 236 Summer Street MAP: 38 LOT: 173 INSTALLER: John Soucy DESIGNER: PLAN DATE: BOH APPROVAL DATE ON PLAN: INSPECTIONS TANK INSPECTION: 5121113 D-BOX DATE OF BED BOTTOM INSPECTION: DATE OF FINAL CONSTRUCTION INSPECTION: DATE OF FINAL GRADE INSPECTION: SITE CONDITIONS ❑ Contractor reports any changes to design plan ❑ Existing septic tank properly abandoned ❑ Internal plumbing all to one building sewer ❑ Topography not appreciably altered Comments: SEPTIC TANK ❑ Building sewer in continuous grade, on compacted firm base ❑ Cleanouts per plan ❑ Bottom of tank hole has 6" stone base ❑ Weep hole plugged ❑ 1500 gallon tank has been installed H-10 loading ❑ Monolithic tank construction ❑ Water tightness of tank has been achieved by visual testing ❑ Inlet tee installed, centered under access port ❑ Outlet tee installed, centered under access port (gas baffle/effluent filter) ❑ inch cover to within 6" of finish grade installed over one access port ❑ Hydraulic cement around inlet & outlet Comments: PUMP CHAMBER ❑ Bottom of tank hole has 6" stone base ❑ Weep hole plugged ❑ 1500 gallon Pump Chamber installed ❑ H-10 loading ❑ Monolithic tank construction ❑ Inlet tee installed, centered under access port ❑ Pump(s) installed on stable base ❑ Alarm float working ❑ Pump On/Off floats working ❑ Separate on/off floats ❑ Drain hole in pressure line ❑ cover at final grade installed over pump access port ❑ Water tightness of tank has been achieved by testing ❑ Hydraulic cement around inlet & outlet Comments: CONTROL PANEL ❑ Alarm & Pump are on separate circuits ❑ Alarm sounds when float is tripped ❑ Location of control panel: basement ❑ Comments: Alarm signal located inside: basement DISTRIBUTION-BOX X Installed on stable stone base X H-20 D-Box X Inlet tee (if pumped or >0.08`/foot) X Hydraulic cement around inlet & outlets ❑ Observed even distribution ❑ Speed levelers provided (not required) Comments: Only one outlet pipe. The flow was slow. I asked him to put speed leveler on outlet pipe.