HomeMy WebLinkAboutCertificate of Compliance - 236 SUMMER STREET 5/21/2013 � ��y�'Siab jryg4"
PUBLIC HEALTH H D PAR 9 R`NT
Town of North Andover
Community Development Division
CERTIFICAT'E OF
COMPLIANCE
As of: 5/21/2013
This is to certify that the individual subsurface disposal system has been installed in accordance
with the provisions of Title 5 of the State Environmental Code:
Repair of D-Box
By: John Soucy
At:
236 Summer Street
Map 38 Lot 173
�% orth Andover, MA 01845
T 6, ssua ce of thisccv rt"ic e'shall no be construed as a guarantee that the system will function satisfactorily.
1VI1chele Grant
Public Health Agent.
I f: COPY
1600 Osgood Street,North Andover,Massachusetts 01845
Phone 978.688.9540 Fox 978.688.8476 Web www.townofnortliandover.com
• �'�f.itD��q
North Andover Health Department
Community Development Division
ONSITE WASTEWATER SYSTEM CONSTRUCTION NOTES
LOCATION INFORMATION
ADDRESS: 236 Summer Street MAP: 38 LOT: 173
INSTALLER: John Soucy
DESIGNER:
PLAN DATE:
BOH APPROVAL DATE ON PLAN:
INSPECTIONS
TANK INSPECTION: 5121113 D-BOX
DATE OF BED BOTTOM INSPECTION:
DATE OF FINAL CONSTRUCTION INSPECTION:
DATE OF FINAL GRADE INSPECTION:
SITE CONDITIONS
❑ Contractor reports any changes to design plan
❑ Existing septic tank properly abandoned
❑ Internal plumbing all to one building sewer
❑ Topography not appreciably altered
Comments:
SEPTIC TANK
❑ Building sewer in continuous grade, on
compacted firm base
❑ Cleanouts per plan
❑ Bottom of tank hole has 6" stone base
❑ Weep hole plugged
❑ 1500 gallon tank has been installed
H-10 loading
❑ Monolithic tank construction
❑ Water tightness of tank has been achieved by
visual testing
❑ Inlet tee installed, centered under access port
❑ Outlet tee installed, centered under access port
(gas baffle/effluent filter)
❑ inch cover to within 6" of finish grade
installed over one access port
❑ Hydraulic cement around inlet & outlet
Comments:
PUMP CHAMBER
❑ Bottom of tank hole has 6" stone base
❑ Weep hole plugged
❑ 1500 gallon Pump Chamber installed
❑ H-10 loading
❑ Monolithic tank construction
❑ Inlet tee installed, centered under access port
❑ Pump(s) installed on stable base
❑ Alarm float working
❑ Pump On/Off floats working
❑ Separate on/off floats
❑ Drain hole in pressure line
❑ cover at final grade installed over pump
access port
❑ Water tightness of tank has been achieved by
testing
❑ Hydraulic cement around inlet & outlet
Comments:
CONTROL PANEL
❑ Alarm & Pump are on separate circuits
❑ Alarm sounds when float is tripped
❑ Location of control panel: basement
❑
Comments: Alarm signal located inside: basement
DISTRIBUTION-BOX
X Installed on stable stone base
X H-20 D-Box
X Inlet tee (if pumped or >0.08`/foot)
X Hydraulic cement around inlet & outlets
❑ Observed even distribution
❑ Speed levelers provided (not required)
Comments: Only one outlet pipe. The flow was slow. I asked him to put speed
leveler on outlet pipe.